Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.7 L+₹67,767.50 (3.08%)Rejected-Finance | L2 | Rejected-Finance Being L2 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
11 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALWAR
GE ALWAR
PREVENTIVE MEASURES AND REPAIR TO DISTRESSED STRUCTURES OF OTM AND MD ACCN AND REJUVENATION OF EXISTING RAIN WATER HARVESTING SYSTEM UNDER AGE B/R (P) AT ITARANA ALWAR
2021_MES_494541_1
8047/E8
Open Tender
Civil Works
Item Rate
210 days
ALWAR
AS PER NIT
3 documents required · 3 mandatory
₹500
GE ALWAR
₹50,000
Yes
19 Feb 2022
14 Dec 2021
13 Jan 2022
14 Dec 2021
11 Jan 2022
29 Dec 2021
14 Dec 2021 - 28 Dec 2021
60 days
Amount
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying or cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Excavation over areas not exc 1.5m deep and getting out in soft/loose soil all as specified and as directed.
Excavation over areas depth exc 1.5m and not exc 3m and getting out in soft/loose soil all as specified and as directed.
Excavation over areas depth exc 3m and not exc 4.5m and getting out in soft/loose soil all as specified and as directed.
Excavation over areas depth exc 4.5m and not exc 6m and getting out in soft/loose soil all as specified and as directed.
Boring holes in soft/loose soil for incasing GI tubing 300mm pipe etc complete all as specified and directed.
S & F 150mm bore PVC pipe for inserting in slotted hole n exc 1cm and depth of hole n exc 150mm bore complete all as speciied and directed by Engr-in-Charge
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level n. exc 1.50 metre above the starting point complete all as specified.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for in this Schedule all as specified & directed.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors and similar works of Gde E-165(Fe 290) including welding etc. complete all as specified & as directed.
Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance complete all as specified & as directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified.
Material and labour preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S&F for pipe cap of 150 mm bore complete all as speified and directed.
M&L loose filling with Gravel of size 12.5mm to be filled around slotted pipe and for bedcomplete all as specified and directed.
M&L for gravel bed for loose filling with Gravel of size 20mm complete all as specified and directed.
M&L for coarse sand bed for loose filling complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed by Engr-in-Charge.
Material and labour 100 mm thick PCC (1:3:6) type C2 using 40 mm graded stone aggregate as in sub base, surface finished fair and even complete all as specified.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
M&L cement concrete (1:3:6) type C1 using 20 mm graded stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc.
Demolition of brick/stone masonry built in cement/lime mortar of any mix and stacking serviceable stones aside for reuse & removing unserviceable materials in low laying area, complete, all as directed by Engr-in-Charge.
Material and labour brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.
All as per serial item No 27.00 here-in-above but except bricks. Note : Old serviceable bricks retrieved from serial item No. 26.00 here-in-before shall be reused under this item.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar 1:4 complete all as specified & as directed.
All as per serial item No. 29.00 here-in-before but except stones. Note : Old serviceable stones retrieved from serial item No. 26.00 here-in-before shall be reused under this item.
Taking down of stone slabs in roofs, suspended floors, chajjas, landings, etc., any description, any thickness, jointed in any mortar all as specified & directed.
M&L for Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in cement mortar 1:6 complete all as specified & as directed.
All as per serial item No 32.00 here-in-above but except stone. Note : Old serviceable stone retrieved from serial item No. 31.00 here-in-before shall be used under this item.
Material and labour for checking of effectiveness of rain water harvesting pit with di-silting chamber including site clearance for working area removed safely all stone patties (if stone pattie break in removal process, same should be replaced, clean the chamber and pit completely, scrap and remove 10 cm layer from top. Fill/pounding the complete pit of approx size 2m x 10m x 2m through chamber twice completely and note the soaking time for accertain the effectiveness of RWH pit complete all as specified and directed.
M&L for precast cement concrete type C1 (1:3:6) 20mm graded stone aggregate as in pcc circular well ring / pcc collar complete all as specified and directed by Engr-in-Charge.
M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed. Note :- Reinforcement shall be measured and paid for separately.
S&F mild steel work such as angle iron in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc) including necessary welding where required as per site requirement and other similar works complete, conforming to Gde E-165 (Fe 290).
Supply and fixing mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 50cm and n exc 75cm long and dia of neck 16 to 20 mm complete all as specified.
Fixing only mild steel galvanized chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire. Note :- Supply only chain link fencing shall be measured and paid for separately.
Supply only mild steel galvanized chain link fencing any size or type as directed complete all as specified. Note:- Flat iron, round bars, nut bolts and washer shall be measured and paid for separately.
S&F mild steel round bars as in tie bars fixed to fencing posts including cut to length, bent to shape, welding of bar at spots as directed and other similar works, conforming to Grade E-165 (Fe 290), complete, all as specified & directed.
Dismantling concrete poles/ struts, any size complete, all as specified & directed.
Dismantling fencing wire mesh of any type of any description fixed to any type of fencing posts.
Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface in soft/ loose soil.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete.
Supply only integral water proofing compound (ISI marked).
M&L Flush pointing in cement mortar (1:3) mixed with 5% of crude oil by weight of cement to bricks laid flat or brick tiles in roofs etc all as specified.
Material and labour for providing and injecting chemical emulsion for post constructional anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion at the rate of 2.25 litre perilinear metre including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 Cement : 2 Coarse sand) to match the existing floors drilling and plugging holes etc complete all as specified and as directed.
Material and labour for providing and injecting chemical emulsion for post constructional anti termite treatment of soil under existing floor using chemical emulsion 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) and match the existing floors using emulsion @1 litre por hole complete all as specified and as directed.
Material and labour for providing and injecting chemical emulsion for post constructional anti termite treatment of voids in masonry, alongwith wall below concrete or masonry apron using chemical emulsion @ 1 litre per holes, soil under existing floors using emulsion @ 1 litre per hole, including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) and match the existing floors complete all as specified and as directed.
M&L anti termite treatment at points of contact of wood work by chemical emulsion (in oil or Kerosene based solution) @ 0.50 litre per hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified & as directed.
M&L for taking down and removal of loose / disintegrated old concrete / plaster and applying 10mm thick bonding coat of modified styrene butadiene emulsion (SBR Bonding agent i.e. Nitobond SBR 45) in proportion 1 (Nitobond SBR 45) : 1(water) : 3 (OPC) by volume with the brushes etc to bind New Cement plaster/ polymer Modified plaster/ concrete/ screed concrete with old surface etc complete.
M&L applying 15mm thick plaster with polymer modified mortar fortified with SBR (Nitobond SBR 45 ) in proportion 1:3 by weight 5 litres Nit bond SBR 45 to added to 50 KG Cement with 13 litre water addition, finished surface to match with existing adjoining surface of ceiling, beams and alike complete.
M&L and applying two or more coats of 2 component zinc based epoxy rust preventer (Nitozinc Primer-M) on corroded reinforcement after cleaning and removing the rust from corroded reinforcement with the help of wire brush and treating it with rust remover (Reebaklens RR) including thoroughly cleaning washing air blowing brushing etc complete. Note : Qty of Zinc based epoxy rust prevent or only shall be taken into account for payment purpose on the basis of actual consumption.
M&L complete removal of washing, rubbing down and stopping of old decorated distempered and painted surface of wall plastered or unplastered including cornices, plasters and preparation of surface of old surface for receiving water proofing compound complete as specified & as directed.
M&L for fixing of 10 mm dia Aqua TP aluminium grouting nipple upto 75-100 mm depth by drilling with 12 mm box hole & fixing in cement mortar at 600 mm above kirting/junction/traps and gravity @10-12 kg/sqm pressure using grouting pump complete all as specified and directed.
M&L for water proofing by applying 2 coats of AQUA PROOF 102 (Styrene butadience system) @ 1Kg/Sqm including cutting 10-12 mm groovs lay plint propeition complete all as specified and directed. Make : Aquashield / Pidilite / Fosroc as approved by GE.
M & L for rendering 20 mm thick in polymer cement mortar 1:3 prepared with latex SBR by the weight of cement on concret and other surfaces including finshing the surfaces even and smooth without using extra cement. Make : Liquid of M/s Choksey / STP / Sika/ Pidilite as approved by GE. Note:- Exact qty and application process of chemical is strictly as per manufacture's guidlines.
M&L for waterproofing treatment by water proofing liquid after proper cleaning of the new surface free of dust and applying the first coat (by Brush only)@ 4-4.5 Sqmt/Lit , allowing it to dry for 24 hrs and applying the second coat over it on horizonal and vertical surface all as specified and directed. Note : Application shall be carried out through authorised applicator of manufacturer only and as per guidelines of Manufacturer strictly. Each stage shall be passed by Engr-in-charge/GE before laying further coat. Make: Sunshield 100 of M/s Choksey or FOSROC / STP / PIDILITE / SIKA as approved by GE.
M&L preparation of old decorated plastered surfaces of walls and applying one coat of cement base paint of approved shade/tint complete all as specified & as directed.
M&L preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil emulsion distemper (OBD) of approved shade/tint all as specified & as directed.
M&L brooming down old decorated surfaces of walls, plastered including cornices, pilasters etc and applying One coats of white wash complete all as specified.
Material and labour preparation of newly plastered surface of walls & applying two coats of cement base paint over a coat of primer complete all as specified.
Material and labour preparation of newly plastered surface of walls & applying three coats of white wash complete all as specified.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer all as specified & as directed.
Material and labour preparation of newly plastered surface of ceiling & applying three coats of white wash complete all as specified.
Demolition of existing lime concrete/PCC padding, roof treatment of any thickness laid over RCC roof/chajja etc., removing complete layer of bitumen under concrete/PCC padding, cleaning and washing of roof with water to remove dust etc as preparation to receive treatment all as directed by Engineer-in-charge.
M&L for padding with PCC 1:2:4, type B0 (using 12.5 mm graded crushed stone aggregate ) laid to a average thickness 50mm thick over roof slab etc as in levelling course, finished even & smooth w/o using extra cement.
M&L for 10mm thick screed bed on fair faces of concrete / brick surfaces in CM 1:4 with water prooofing compound @ 3% by weight of cement inorder to maintain proper slope over existing roof surfaces / Sunken floor for laying APP based polymeric membrain finished complete all as directed.
Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.5 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd or Hydrostop water proofing memdrane manufactured by M/S TIKIDAN as approved by GE, black finish reinforced with non-woven polyester matt (weighing not less than 150 gm/Sqm), with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing.(iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen. (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate. (vii) The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.
M/S JALANDRA CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .