Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC SAHEBPARA RAOD UPPER BAGDOGRA P O BAGDOGRA DISTRICT DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹43.6 L+₹9.3 L (27.3%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Jan 2021, 6:00 pmClosed
GE BENGDUBI
Bengdubi Military Station PO-Bengdubi, Dist-Darjeeling, Pin 734424
GE/BENG/57 OF 2020-21 REPAIR / RENEWAL OF CEILING FAN, OTHER FAN AND REPAIR / REPLACEMENT / IMPROVEMENT OF OVER HEAD CONDUCTOR TO GROUND AND CONNECTED NECESSARY WORK AT CERTAIN UNITS UNDER GE BENGDUBI MIL STN
2020_MES_406405_1
GE/BENG/57 OF 2020-21
Open Tender
Civil Works
Item Rate
270 days
GE BENGDUBI
MES Enlisted/ Un-enlisted contractor of Class D and above with category b(i)
8 documents required · 8 mandatory
₹500
GE BENGDUBI
₹90,000
Yes
8 Feb 2021
23 Dec 2020
22 Jan 2021
23 Dec 2020
20 Jan 2021
8 Jan 2021
26 Dec 2020 - 2 Jan 2021
Amount
SCHEDULE 'A'
Dismantling of ACSR or AAC condutor from LT service feeder or distribution line complete all as specified and directed by Enge-in-Charge.
Dismantling cross arms of MS channels or angle sections etc complete all as specified and directed by Enge-in-Charge.
Dismantling insulators any type any sizes complete all as specified and directed by Enge-in-Charge.
M&L for earthing complete of advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgrated (Zinic & alloy coated) Zinic coated (80-100) microns with pure (99.9%) & alloy coating (200-250) microns earthing system confirming IS-3034 the outer and inner pipe should be 76.2mm & 41.9mm dia 3 mtr length zinic coated with additional special alloy coating 300mm on the topside for additional protection of the terminal the annular space between the pipes being filledup with compact fill(CF) (Crystalline conductive compound) the compact fill (CF) mixture which is machine pressed in the pipes should not disintgrate or collapse when outer pipe corrods, the inner pipe should be extended with terminals for connectivity. The job includes digging the pits and refilling the same by electrode/conductolite back fill compound (Ground enhancer)the BFC should dbe eco friendly it should not contain environmentally hazard materials having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP earth pitcover for protection and safe guard of terminals. In area where soil condition is bad good earth is to be arranged to fill the excavated pits by mixing the same with BFC 4 bags (as per soil condition) extra perpit/unit. As earth electrode is the main component of the earthing system which is indirect contact with the ground and thus provides ameans of releasing or collecting earth leakage current. The materials should have a good electrical conductivity & anti corrosion properrty in wide range of soil condition complete and testing on completion including dismantlingh unserviceable earthing complete all as specified and directed Make ASHLOK Model ASEELor equivalent Note:- Earth result should be obtain minimum 1 Ohm.
S&F in repairs MCCB 160 Amps, 3 Pole, 415 V, Adjustable type, with breaking capacity 25 KA, 100 % ICU including spreader terminals & connected accessories complete as specified and as directed. Make:- Legrand / ABB / Siemens or equivalent
S&F in repairs MCCB 200 Amps, 3 Pole, 415 V, Adjustable type, with breaking capacity 25 KA,100 % ICU including spreader terminals & connected accessories complete as specified & directed.Make:- Legrand / ABB / Siemens or equivalent
S&F in repairs MCCB 250 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 25 KA, 100 % ICU including spreader terminals & connected accessories complete as specified & directed.Make:- Legrand / ABB / Siemens or equivalent
S&F in repairs MCCB 320 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA, 100% ICU including spreader terminals & connected accessories complete as specified & directed. Make:- Legrand / ABB / Siemens or equivalent
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed.
Returning, filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed.
M&L well burnt bricks old size class 'B' laid flat across the cable for cable protection in trenches complete all as specified and as directed
Supply, Laying and testing XLPE insulated, armoured heavy duty electric cables with aluminum conductor, cross sectional area 6 Sqmm 2 Core 1100 volt grade laid in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with cable size aluminum lugs all as specified. (Note: Excavation shall be measured and paid separately under respective items of Sch 'A'/BoQ)
Ditto all as per item no. 14.00 here-in-before but 10 Sqmm 2 core
Ditto all as per item no. 14.00 here-in-before but 25 Sqmm 3.5 core
Ditto all as per item no. 14.00 here-in-before but 50 Sqmm 3.5 core
Ditto all as per item no. 14.00 here-in-before but 70 Sqmm 3.5 core
Ditto all as per item no. 14.00 here-in-before but 95 Sqmm 3.5 core
Taking out existing old/unserviceable underground electric cable of any size/type from trenches, roof , ducts, pole etc and removing from the site all as specified and directed. Note:- Excavation and earth work shall be measured and paid separately under respected item of Sch ‘A’/BoQ
Material and labour for surface dressing averaging 15cm depth in soft/loose soil for cleaning and cutting /removal of green vegetation in and around the installations and removla of the soil outside of the installation including spreading thin layer of anti vegetation chemical to prevent abnormal growth of grass/bushes complete all as specified and directed.
Cutting and trimming of tree branches of any grith all around the LT over head lines upto 2 mtr from all around the over head lines complete and removing the cut branches from the site to a distances not exc 50 mtr all as sprcified and directed.
M&L for painting of LT Steel tubular pole (9 mtr long) any type or size externally above foundation including all MS work with one coats of aluminium paint after scrapping / clearing well the existing surface all as directed and as specefied (The above work includes painting of 3 Nos black & 02 nos yellow bands width 30 Cm by fluorescent paint in alternate layers upto 1.5 mtr height above foundation / plinthblock)
M & L for painting of 9 m PCC pole with cement wash two coat by using the cement and two coat of aluminium paint over cross arms, clamp of any length and shape for LT overhead line including preparation of the existing surface including marking pole numbers in a 15 cm dia yellow circle & marking three black & two yellow bends width 30 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height, complete all as specified and directed.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Bus bar Feeder pillar box 'Pedastal type' Confirming to IP 43, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators, All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete. Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply. :- Incoming (a) Aluminium bus bar - 300 amps rating - 03 Nos. for phases and 150 amp rating - 01 No. for neutral
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Feeder pillar box 'Pedastal type' Confirming to IP 43, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply. Incoming (a) Aluminium bus bar - 300 amps rating - 03 Nos. for phases and 150 amp rating - 01 No. for neutral
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Feeder pillar box 'Pedastal type' Confirming to IP 43, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply. Incoming (a) Aluminium bus bar - 300 amps rating - 03 Nos. for phases and 150 amp rating - 01 No. for neutral
S&F sintex fibre body loopin loopout enclosure of size 230mm x 170mm x 105mm consisting of 4 Nos aluminium busbar of size 150mm x 20mm x 2mm thick fixed on porceline support inside enclosure fixing of enclosure with pole using 40 x 6mm size MS FI clamps of required shape with bolts, nuts & washers complete all as specified and directed.
M&L for Wiring for 3 core cable 2.5 sq. mm of FRLS PVC insulated copper conductor, in existing surface/ recessed/on pole and necessary flexible pile/pvc conduit pit etc. as required
M&L for horizontal boring under the road below 1 mtr from the road surface and dia of hole not exc 100 mm without damaging the existing road getting out and disposal of soil to a distance not exceeding 50 m from the site of work all as specified and as directed.
S&F in repair of GI Pipe 100 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturb surfaces and sound coundition complete all as specified and as directed.
S&F in repair of GI Pipe 25 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturb surfaces and sound coundition complete all as specified and as directed.
Checking of ceiling fan 1200mm sweep at site when and where required as MES complaint slip on daily basis if reqired excepting sunday and holidays in existing position including Supply and fixing as replacement at site in position ceiling fan condensor 2.5 mfd all as spcified and as directed (Make - USHA/UNIVERSAL/Havells}.
Ditto all as per item No.36.00 above but ceiling fan 1400mm sweep when and where required as MES complaint slip on daily basis if reqired excepting sunday and holidays and ceiling fan condensor 2.5 mfd all as spcified and as directed
Taking down carefully ceiling fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades to the work shop including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connection and material and labour for replacement of two nos split pins, one connection block and one rubber reel all as specified and as directed. Note : i) Rewinding work of armature (if any) shall be measured and paid separately ii) New spare parts required for replacing old burn out parts other than connector,split pins, connection block and rubber reel shall be measured and paid separately as ‘ Supply only’ under item No 46.00 to 50.00 here-in-after. iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200mm sweep fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Ditto all as pr item No.39.00 here-in-before but for 1400mm sweep ceiling fan all as specified and as directed.
Taking down carefully existing exhaust fan of any size sweep and any make after disconnecting the electrical connection, and removing the exhaust fan with blade to the work shop including cleaning of dust and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) re-assembling the fan complete , testing and refixing the fan in same position including all electrical connection and material and labour for replacement of one connection block all as specified and as directed. Note : i) Rewinding work (if any) shall be measured and paid separately ii) New spare parts required for replacing old worn out parts other than connector, shall be measured and paid separately as ‘ Supply only’ under item No 46.00 to 50.00 here-in-after. iii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for upto 300 mm sweep exhust fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Ditto all as pr item No.42.00 here-in-before but for 450 mm sweep ceiling fan all as specified and as directed.
Material and labour for painting of ceiling fans complete of any sweep/make with one coat of first quality synthetic enamell paint of approved tint by spray including preparation of old painted surface and removing all dust, oil mark etc and filling cavaties with filler materials,and writing serial / MES number as specified (with paint of black colour with each letters/figures in Block of height n.exc2 cm ) complete all as specified and as directed.
Ditto all as pr item No.44.00 here-in-before but for painting to exhaust fans with blade complete of any sweep/make all as specified and as directed.
Supply only bearing No.6201/6202 for ceiling /Exhaust fan (Make - TATA/SKF/NBC ).
Supply only bearing No.6203/6204 for ceiling/ Exhaust fan (Make - TATA/SKF/NBC ).
Supply only fan condensor 3.15 mfd (Make - USHA/UNIVERSAL/Havells}.
Supply only fan condensor 2.5 mfd (Make - USHA/UNIVERSAL/Havells).
Supply only gun metal bush of any size (Make - TATA/MSP).
Supply only mounting clamp assembly complete for ceiling fan 1200mm/1400mm sweep with amp,bolt,nut,washers, safety/ split pins and rubber bush and all as specified and directed.
Supply only down rod assembly complete for ceiling fan 1200mm/1400mm sweep all as specified and directed.
Supply and fixing in replacement louvers shutters for Exhaust fan of any size up to 450 mm sweep suitable for any make made of MS sheet including two coat of synthetic enamel paint over a coat of red oxide and bolt,nut,washers etc complete including taking down old unserviceable one all as directed.
Taking down carefully wall fan of any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades to the work shop including cleaning and dismantling the fan into parts and segregation of unserviceable parts, replacement of unserviceable spares parts with new parts including necessary machining work and lubricating with approved grade of grease and necessary minor soldering work (if required) and re-assembling the fan complete and testing and refixing the fan in same position including all electrical connection. Note : i) Rewinding work of armature (if any) shall be measured and paid separately ii) Labour cost for replacing spare parts are deemed to be inclusive in the quoted rate.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for wall fan of any size with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Material and labour for flexible multi stranded copper wire twin twisted two core of size 0.75 sqmm all as specified and as directed.(Make:Havells/Plaza/Polycab)
Supply and fixing Ceiling fan of Size 1200mm sweep, 230 volt Ac with connection from existing celing rose with MS hooke for hanging of suitable size all as specified and as directed Make :-Polar/Havells/Bajaj.
Supply and fixing Pvc Exhaust fan of Size 200 mm sweep, 230 volt Ac with connection from existing celing rose with Louver Shutter all as specified and as directed Make :-Polar/Havells/Bajaj.
Supply and fixing Pvc Exhaust fan of Size 250 mm sweep, 230 volt Ac with connection from existing celing rose with Louver Shutter all as specified and as directed Make :-Polar/Havells/Bajaj.
Supply and fixing Exhaust fan metal body of Size 300mm sweep, 230 volt Ac with connection from existing celing rose with Louver Shutter all as specified and as directed Make :-Polar/Havells/Bajaj.
Supply and fixing Exhaust fan metal body of Size 380mm sweep, 230 volt Ac with connection from existing celing rose with Louver Shutter all as specified and as directed Make :-Polar/Havells/Bajaj.
Supply and fixing Exhaust fan metal body of Size 450 mm sweep, 230 volt Ac with connection from existing celing rose with Louver Shutter all as specified and as directed Make :-Polar/Havells/Bajaj.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 38221.00 (refer Tender Srl Page No 34). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
M/S SUPARNA ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .