Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAdmitted-Finance | ₹15.6 L | L1 | Admitted-Finance |
| 2 | L2₹16.2 L+₹58,630 (3.76%)Admitted-Finance GF 3 F 12 KSSIDC BUILDING 5TH CROSS 1ST STAGE PEENYA INDUSTRIAL ESTATE BANGALORE | BENGALURU URBAN | KARNATAKA | 560058 | ₹16.2 L+₹58,630 (3.76%) | L2 | Admitted-Finance |
| 3 | L3₹16.2 L+₹59,654 (3.83%)Admitted-Finance ADHYARU INDUSTRIAL EST STORE NO 3 1ST FLOOR SUN MILL COMPOUND LOWER PAREL MUMBAI 400013 | MUMBAI | MUMBAI | MAHARASHTRA | 400013 | ₹16.2 L+₹59,654 (3.83%) | L3 | Admitted-Finance |
| 4 | L4₹16.5 L+₹96,750 (6.21%)Admitted-Finance 73 NIL SHOP 1AND 2 PLOT 73 GRUHLAXMI BUILDING OPP RYAN INTERNATIONAL SCHOOL KHARGHAR NAVI MUMBAI RAIGAD MAHARASHTRA 410210 | RAIGAD | MAHARASHTRA | 410210 | ₹16.5 L+₹96,750 (6.21%) | L4 | Admitted-Finance |
| 5 | L5₹19.1 L+₹3.5 L (22.8%)Admitted-Finance 61 62 6TH FLOOR 61 62 6TH FLOOR KALPATARU SQUARE KONDIVITA ROAD OFF ANDHERI KURLA ROAD ANDHERI EAST MUMBAI MAHARASHTRA 400059 MUMBAI MAHARASHTRA 400059 | MUMBAI SUBURBAN | MAHARASHTRA | 400059 | ₹19.1 L+₹3.5 L (22.8%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Prostarm Info Systems limited L6 | Power One Micro Systems (P) Ltd L2 | Ramesh Electrical and Mechanical Works L3 | rsp power solutions L4 | ask enterprises L1 | Novateur Electrical and Digital Systems Private Limited L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply of 3 phase + Neutral input and 3 phase + Neutral output 415volt , 50HZ , 80KVA online UPS, 30 min. power Backup, advance Level 3 IGBT based rectifier technology , True Online double conversion must handle regenerative loads, along with inbuilt Galvanic Isolation Transformer and RS232, RS485, Relay contact , connectivity. IP21 Including battery breaker MCCB AND ENCLOSURE
Isolation: Built-in Isolation Transformer for Galvanic Isolation
Overload Capacity: Defined at 40°C without battery support
Input Features: Built-in Phase Sequence Reversal Detection & Correction
Compatibility: 3-Phase, 3-Wire Rectifier – Fully compatible with existing infrastructure
Fault Protection: High Short Circuit Current for better fault discrimination
Load Handling: Supports all types of machine loads, including regenerative loads
STD Accessories: Open Battery racks, Interconnection Cables, Connecting Lugs, Battery Isolator, and UPS to Battery cable of required length etc.
as per technical specifications mentioned in tender documents The UPS to be used for feeding power supply to HVAC ( Air conditioning system Air cooled chillers 18 Tr capacity and other 3 phase motor and machine load ) The UPS must feed un interrupted power to chillers in case of mains failure for 30 Min. Warrantee of UPS for 01 year from the date of Handing over of the complete system. During power failure the Chiller start than the UPS must take starting load of connected Chiller system with battery backup. Agency requested to visit the site to check connected load before quoting. | 1 | Each | 6,00,000 ₹6,00,000 Lowest | 6,57,000 ₹6,57,000 | 7,38,705 ₹7,38,705 | 8,65,000 ₹8,65,000 | 8,00,000 ₹8,00,000 | 7,29,765 ₹7,29,765 |
| 2.00 | Supply of SMF batteries setup to provide 30 Minutes power backup including all connection studs, accessories, jelly , complete in all respect. Battery Type should be No maintenance battery/SMF of reputed brand having ISO 9001:2008 & ISO 4001 BIS/ISI for quality and environment charged complete with 24 months warranty complete from the date of commissioning and handing over of site. Warrantee of Battery for 02 years from handing over of the system on letterhead of battery OEM. | 1 | Lot | 5,70,000 ₹5,70,000 | 6,00,880 ₹6,00,880 | 6,30,044 ₹6,30,044 | 4,30,000 ₹4,30,000 Lowest | 5,00,000 ₹5,00,000 | 5,21,830 ₹5,21,830 |
| 3.00 | SITC of Input and output distribution panel having TPN MCCB 125A, 36KA , MCCB FROH 415V,50Hz, having outside rotary operated mechanism , phase spreader , R Y B Indication lamp , On OFF Trip Indication lamp ,with enclosure box cable spreader , Manual, with integral LSI protection, earthing for panel , wall mounted fixing accessories as per specifications mentioned in tender documents | 2 | Each | 2,50,000 ₹5,00,000 | 52,000 ₹1,04,000 | 22,534 ₹45,068 | 52,250 ₹1,04,500 | 16,500 ₹33,000 Lowest | 1,09,470 ₹2,18,940 |
| 4.00CABLING Power Cabling Supply and laying heavy duty 1100V grade XLPE outer sheathed & Fire Retarded Low Smoke (FRLS) cables indoor with Copper conductors as specified complete with: a) Cable clamps / trays on walls, floors, ceiling as required. b) Earthing the glands armouring etc. | |||||||||
| 5.00 | SITC of Incomer cable from main input MCCB distribution board to UPS Incomer 1CX50 Sqmm Copper cable multi strand type including glanding and lugging ( Lug Qty 8 nos) . | 35 | Mtr | 3,000 ₹1,05,000 | 1,000 ₹35,000 | 738 ₹25,830 | 713 ₹24,955 Lowest | 775 ₹27,125 | 1,685 ₹58,975 |
| 6.00 | SITC of Outgoing cable from UPS output to main output MCCB distribution board 1CX50 Sqmm Copper cable multi strand type including glanding and lugging ( Lug Qty 08 Nos) ( Neutral cable lug Qty 02 nos ) | 35 | Mtr | 3,500 ₹1,22,500 | 1,000 ₹35,000 | 739 ₹25,865 | 731 ₹25,585 Lowest | 775 ₹27,125 | 1,685 ₹58,975 |
| 7.00 | SITC of Tinned copper earth plate electrode 600 x 600 x 3.15 mm earth station, including 5MTR copper Strip 25 X 3 MM for each pit , 2.5 mtr below ground level as per drawing complete with all required materials like Cole, charcoal, salt, brass nut bolts & washers, watering arrangements, GI pipe (B class), concrete chamber, heavy duty cast iron cover plate & excavation in all types of soil in ground refilling & removal excess earth within a radius of 500 mtr. Etc. Note:1.The chamber cover & plate shall be of heavy-duty hinged type & it shall weigh approx. 65 to 75 Kgs. For 450 x 450 mm size & shall be got approved by dept. (6 mm chequred plate with 40 x 40 x 6 mm angle iron frame)2.Plastering shall be done both inside & out side.3.The measurement of resistance of earth station & resistance of complete scheme of earthing layout shall be measured, recorded & got approved by Engg-in-charge. | 1 | Each | 50,000 ₹50,000 | 45,500 ₹45,500 | 39,487 ₹39,487 | 69,630 ₹69,630 | 21,000 ₹21,000 Lowest | 82,410 ₹82,410 |
| 8.00 | Supply, Installation, Testing and commissioning of 25 mm x 3 mm COPPER strip on surface or in recess for connections etc. as required including all fixing accessories | 30 | Mtr | 2,500 ₹75,000 | 1,040 ₹31,200 | 716 ₹21,480 Lowest | 726 ₹21,780 | 890 ₹26,700 | 2,337 ₹70,110 |
| 9.00 | SITC of 3. 5x 70 Sqmm aluminium armoured cable 1.1 KVA FRLS , XLPE PVC Insulated cable including double compression type glanding ( Qty 02 Nos ) , lugging ( Qty 08 Nos ) , Manual excavation of soft / hard soil for underground cable laying up to 900 mm , backfilling of excavated area , clamping , saddling of cable on walls , trench etc. | 125 | Mtr | 3,000 ₹3,75,000 | 780 ₹97,500 | 549 ₹68,625 Lowest | 858 ₹1,07,250 | 780 ₹97,500 | 1,235 ₹1,54,375 |
| 10.00 | Charges of installation and commissioning of UPS batteries. | 1 | set | 50,000 ₹50,000 | 10,000 ₹10,000 | 22,000 ₹22,000 | 5,500 ₹5,500 Lowest | 25,000 ₹25,000 | 16,500 ₹16,500 |
Tender Value
₹16.5 L
EMD Value
₹33,059
Closing Date
9 Jul 2025, 3:00 pmClosed
Director,TMC
Office of Engineering Services, Second Floor, Khanolkar Shodhika, ACTREC Kharghar Node, Navi Mumbai - 410210
SITC of 80KVA UPS including batteries and accessories for supplying power to chiller in Bio Bank building, at ACTREC campus
2025_TMC_861541_1
ET-22/80 KVA UPS/2025
Open Tender
Electrical Works
Item Rate
150 days
ACTREC, Kharghar
As per Tender Document
2 documents required · 2 mandatory
₹0
₹33,059
ACTREC,Kharghar
17 Sept 2025
26 May 2025
10 Jul 2025
26 May 2025
9 Jul 2025
26 May 2025
26 May 2025 - 3 Jun 2025
4 Jun 2025
Amount
Supply of 3 phase + Neutral input and 3 phase + Neutral output 415volt , 50HZ , 80KVA online UPS, 30 min. power Backup, advance Level 3 IGBT based rectifier technology , True Online double conversion must handle regenerative loads, along with inbuilt Galvanic Isolation Transformer and RS232, RS485, Relay contact , connectivity. IP21 Including battery breaker MCCB AND ENCLOSURE Isolation: Built-in Isolation Transformer for Galvanic Isolation Overload Capacity: Defined at 40°C without battery support Input Features: Built-in Phase Sequence Reversal Detection & Correction Compatibility: 3-Phase, 3-Wire Rectifier – Fully compatible with existing infrastructure Fault Protection: High Short Circuit Current for better fault discrimination Load Handling: Supports all types of machine loads, including regenerative loads STD Accessories: Open Battery racks, Interconnection Cables, Connecting Lugs, Battery Isolator, and UPS to Battery cable of required length etc. as per technical specifications mentioned in tender documents The UPS to be used for feeding power supply to HVAC ( Air conditioning system Air cooled chillers 18 Tr capacity and other 3 phase motor and machine load ) The UPS must feed un interrupted power to chillers in case of mains failure for 30 Min. Warrantee of UPS for 01 year from the date of Handing over of the complete system. During power failure the Chiller start than the UPS must take starting load of connected Chiller system with battery backup. Agency requested to visit the site to check connected load before quoting.
Supply of SMF batteries setup to provide 30 Minutes power backup including all connection studs, accessories, jelly , complete in all respect. Battery Type should be No maintenance battery/SMF of reputed brand having ISO 9001:2008 & ISO 4001 BIS/ISI for quality and environment charged complete with 24 months warranty complete from the date of commissioning and handing over of site. Warrantee of Battery for 02 years from handing over of the system on letterhead of battery OEM.
SITC of Input and output distribution panel having TPN MCCB 125A, 36KA , MCCB FROH 415V,50Hz, having outside rotary operated mechanism , phase spreader , R Y B Indication lamp , On OFF Trip Indication lamp ,with enclosure box cable spreader , Manual, with integral LSI protection, earthing for panel , wall mounted fixing accessories as per specifications mentioned in tender documents
CABLING Power Cabling Supply and laying heavy duty 1100V grade XLPE outer sheathed & Fire Retarded Low Smoke (FRLS) cables indoor with Copper conductors as specified complete with: a) Cable clamps / trays on walls, floors, ceiling as required. b) Earthing the glands armouring etc.
SITC of Incomer cable from main input MCCB distribution board to UPS Incomer 1CX50 Sqmm Copper cable multi strand type including glanding and lugging ( Lug Qty 8 nos) .
SITC of Outgoing cable from UPS output to main output MCCB distribution board 1CX50 Sqmm Copper cable multi strand type including glanding and lugging ( Lug Qty 08 Nos) ( Neutral cable lug Qty 02 nos )
SITC of Tinned copper earth plate electrode 600 x 600 x 3.15 mm earth station, including 5MTR copper Strip 25 X 3 MM for each pit , 2.5 mtr below ground level as per drawing complete with all required materials like Cole, charcoal, salt, brass nut bolts & washers, watering arrangements, GI pipe (B class), concrete chamber, heavy duty cast iron cover plate & excavation in all types of soil in ground refilling & removal excess earth within a radius of 500 mtr. Etc. Note:1.The chamber cover & plate shall be of heavy-duty hinged type & it shall weigh approx. 65 to 75 Kgs. For 450 x 450 mm size & shall be got approved by dept. (6 mm chequred plate with 40 x 40 x 6 mm angle iron frame)2.Plastering shall be done both inside & out side.3.The measurement of resistance of earth station & resistance of complete scheme of earthing layout shall be measured, recorded & got approved by Engg-in-charge.
Supply, Installation, Testing and commissioning of 25 mm x 3 mm COPPER strip on surface or in recess for connections etc. as required including all fixing accessories
SITC of 3. 5x 70 Sqmm aluminium armoured cable 1.1 KVA FRLS , XLPE PVC Insulated cable including double compression type glanding ( Qty 02 Nos ) , lugging ( Qty 08 Nos ) , Manual excavation of soft / hard soil for underground cable laying up to 900 mm , backfilling of excavated area , clamping , saddling of cable on walls , trench etc.
Charges of installation and commissioning of UPS batteries.
Power One Micro Systems (P) Ltd (BID ID -3230817)
Ramesh Electrical and Mechanical Works (BID ID -3232814)
rsp power solutions (BID ID -3236460)
Novateur Electrical and Digital Systems Private Limited (BID ID -3221238)
Prostarm Info Systems limited (BID ID -3230035)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .