| Sl No | Description | Qty | Unit | Premier Engineering Company | R K CORRUGATEDBOX AND ALLIED PRODUCTS | Raj Engineering Co. | TUSHAR ENTERPRISES | Shivam Enterprises |
|---|---|---|---|---|---|---|---|---|
| 1.00 | LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1600MM x1800x375MM. Having following components of approved make. | 1 | Nos. | 85,000 ₹1,00,300 | 1,00,000 ₹1,18,000 | 63,000 ₹74,340 Lowest | 63,000 ₹74,340 Lowest | 65,000 ₹76,700 |
| 2.00 | MCCB 415V, FP 3phase High breaking capacity 50KA 50Hz,250Amp with spreader - Make L&T/Siemens | 1 | Nos. | 16,985 ₹20,042.3 | 9,500 ₹11,210 Lowest | 16,500 ₹19,470 | 31,500 ₹37,170 | 32,800 ₹38,704 |
| 3.00 | MCCB 415V, FP 3phase High breaking capacity 50KA 50Hz,125Amp with spreader - Make L&T/Siemens | 2 | Nos. | 22,744 ₹26,837.92 | 17,000 ₹20,060 | 9,400 ₹11,092 Lowest | 45,000 ₹53,100 | 47,400 ₹55,932 |
| 4.00 | MCB Single pole 6Amp. Make L&T/Siemens | 6 | Nos. | 1,080 ₹1,274.4 | 870 ₹1,026.6 Lowest | 960 ₹1,132.8 | 2,100 ₹2,478 | 2,280 ₹2,690.4 |
| 5.00 | MCB Triple pole 32Amp Make L&T/Siemens | 1 | Nos. | 850 ₹1,003 Lowest | 2,150 ₹2,537 | 950 ₹1,121 | 950 ₹1,121 | 980 ₹1,156.4 |
| 6.00 | MCB Triple pole 63Amp Make L&T/Siemens | 1 | Nos. | 1,820 ₹2,147.6 | 3,200 ₹3,776 | 1,350 ₹1,593 | 1,250 ₹1,475 Lowest | 1,255 ₹1,480.9 |
| 7.00 | PVC insulated copper flexible cable single core 35 sq.mm Make: Havells/Finolex | 100 | Mtr | 41,000 ₹48,380 | 41,100 ₹48,498 | 31,000 ₹36,580 Lowest | 48,000 ₹56,640 | 48,800 ₹57,584 |
| 8.00 | Power capacitors 415V unit of 35Kvar Make: Epcos/L&T | 1 | Nos. | 6,300 ₹7,434 | 7,000 ₹8,260 | 3,900 ₹4,602 | 450 ₹531 Lowest | 455 ₹536.9 |
| 9.00 | Over load relay 50-70 Amp Range Make: L&T/Siemens | 2 | Nos. | 5,654 ₹6,671.72 Lowest | 9,000 ₹10,620 | 7,800 ₹9,204 | 7,300 ₹8,614 | 7,310 ₹8,625.8 |
| 10.00 | Over load relay 8-12 Amp Range Make: L&T/Siemens | 2 | Nos. | 1,990 ₹2,348.2 Lowest | 6,400 ₹7,552 | 3,800 ₹4,484 | 4,900 ₹5,782 | 4,912 ₹5,796.16 |
Tender Value
Refer Docs
EMD Value
₹8,600
Closing Date
25 Jul 2025, 2:00 pmClosed
EXECUTIVE ENGINEER (EM) M-10
GREATER KAILASH, PART-I, NEW DELHI
Repair/Renovation of LT Distribution panel at Vasant Apartment BPS in R.K Puram AC-44.
2025_DJB_275650_20
NIT No. 7/EE(EM)M-10/(25-26)
Open Tender
Electrical Work/ Equipment
Works
30 days
EXECUTIVE ENGINEER (EM) M-10
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹8,600
Yes
18 Sept 2025
18 Jul 2025
25 Jul 2025
18 Jul 2025
25 Jul 2025
18 Jul 2025
LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1600MM x1800x375MM. Having following components of approved make.
MCCB 415V, FP 3phase High breaking capacity 50KA 50Hz,250Amp with spreader - Make L&T/Siemens
MCCB 415V, FP 3phase High breaking capacity 50KA 50Hz,125Amp with spreader - Make L&T/Siemens
MCB Single pole 6Amp. Make L&T/Siemens
MCB Triple pole 32Amp Make L&T/Siemens
MCB Triple pole 63Amp Make L&T/Siemens
PVC insulated copper flexible cable single core 35 sq.mm Make: Havells/Finolex
Power capacitors 415V unit of 35Kvar Make: Epcos/L&T
Over load relay 50-70 Amp Range Make: L&T/Siemens
Over load relay 8-12 Amp Range Make: L&T/Siemens
Amp. Meter Digital Make AE/L&T
Volt Meter Digital Make AE/L&T
Motor protection Relay Make: L&T/Siemens
Power contactor 220V 3phase 120 Amp. Make L&T/Siemens
Power contactor 220V 3phase 32 Amp. Make L&T/Siemens
Star delta timer on delay make: L&T/Siemens
Indicating lights LED type RYB & On/OFF Make : L&T /Havells/Siemens
Current Transformer200/5,100/5,30/5 Make AE /Advance
On load change over switch 250 Amp. Open execution type Make: L&T/Havells
Internal wiring with copper wire as pr CPWD specification for light power & plug points in recess /surface /Main distribution board for pump house having 6Nos. light points, & fan point 2Nos. Power Point-2Nos.
Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares, control wiring in 1.5sq mm wire complete in all respect.
Dismantling of old panel, structure, damaged components and Installation of the panel at site by making foundation ,termination of cable both incoming & out going side ,mongering of complete panel , including cable connection,. This includes cartage, loading& unloading etc.
Testing & commissioning of the panel with relevant IS as follow: - Check equipments specification - Continuity and ear thing -MCCB mechanism and alignment -Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth. - All functional tests -Checking for all tightness of nuts and bolts -Alignments of doors etc. -interlocking tests
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .