| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC VILLAGE KOJINDA POST OFFICE MANDHANA TEHSIL NARNAUL DISTRICT MOHINDERGARH HARYANA 123001 | NARNAUL | MOHINDERGARH | HARYANA | 123001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.5 L+₹89,030.03 (19.3%)Rejected-Finance 1350 B SHYAM LAL BAGH NEAR NAND CINEMA HISAR 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Elect Licence , Enlistment(Electrical) and HEW Reg not attached |
Tender Value
₹4.4 L
EMD Value
₹8,800
Closing Date
12 Dec 2023, 5:00 pmClosed
RAVI Ladwal
ED - Rewari
Construction of Multipurpose Hall in Government College, Narnaul in Distt. Mohindergarh (Pdg. EI Internal)(Balance work)
2023_HRY_332105_1
202304F44593 AADE 4539 92B6 BBBE4C5B93CD668BAR
Open Tender
Civil Works
Works
90 days
Narnaul
Refer DNIT
2 documents required · 2 mandatory
₹500
₹8,800
Yes
23 Jan 2024
30 Nov 2023
13 Dec 2023
30 Nov 2023
12 Dec 2023
30 Nov 2023
Amount
[23.1.5.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 5.2. Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group B
[23.1.6.1]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.1. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)
[23.1.6.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.2. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm)
[23.20]Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP
[23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)
[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
[23.22.5.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.5. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs TRIPLE POLE
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE
[23.23.2.1]MISCELLANEOUS 2.1. Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia
[23.6.6.2]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia.
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
[24.2.5.2]LT CABLE 5.2. Laying and fixing of cable on surface/ cable tray etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core
[24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core
[24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core
[24.4.5]STREET LIGHT 5. Supply and erection of Single Phase weather proof M.S. box of size 20 cm x 15 cm x 10 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 6 amp SP MCB and 1 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box including painting and necessary connections.
[24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia
Supply and erection of M.S box of size 8`x10`x4` (200mm x 250mm x 100mm deep) made of 1.6 mm thick M.S. sheet covered with 5 mm thick bakelite sheet with cost and fixing 4 nos. sockets and switch of 6 amp and one no. multi socket and switch of 15 amp including fixing of 1 no. fuse unit and indicatior of anchor make. the M.S. box duly recessed in wall including painting of M.S. box, cost of necessary cement and sand mixture complete in all respect upto the entire satisfaction of Engineer-in-charge of work. (for computer point ) Make as per make list (copy attached)
supply and erection of 95X3.5mm ard. Aluminium cable in existing pipe/surface make Pymen/Suraj
Supply and erection of 35sqmm 3.5 C under ground cable, on surface / cable tray etc. complete with necessary connections.
pawan Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .