| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.1 LAccepted-AOC AT ADDRESS BACHRA CHATRA JHARKHNAD 829210 | L-1 | Accepted-AOC As per recommendation of TC and Approval of Competent Authority | |
| 2 | L-2₹4.3 L+₹17,585.67 (4.28%)Rejected-Finance 51 RAHAM RAHAM TANDWA CHATRA JHARKHAND 825321 | CHATRA | JHARKHAND | 825321 | L-2 | Rejected-Finance As per recommendation of TC and approval of competent authority | |
| 3 | L-3₹4.5 L+₹40,247.58 (9.79%)Rejected-Finance ARA P O GANESHPUR DIST LATEHAR PIN 829202 | LATEHAR | JHARKHAND | 829202 | L-3 | Rejected-Finance As per recommendation of TC and approval of competent authority | |
| 4 | L-4₹4.7 L+₹55,741.76 (13.6%)Rejected-Finance | L-4 | Rejected-Finance As per recommendation of TC and approval of competent authority | |
| 5 | L-5₹6.7 L+₹2.6 L (63.8%)Rejected-Finance AT P O RAHAM P S TANDWA PIN 825321 | RAHAM | CHATRA | JHARKHAND | 825321 | L-5 | Rejected-Finance As per recommendation of TC and approval of competent authority |
Tender Value
₹6.1 L
EMD Value
₹7,580
Closing Date
16 Oct 2024, 6:00 pmClosed
Staff Officer (EnM),Magadh -Sanghmitra Area
Office of The General Manager M-S Area, Bachra. 829201
Day to Day Annual Maintenance contract of electrical wiring of Avantika Transit camp and repairing/replacement of light,fan, and other miscellaneous electrical items as per requirement of 147 number Temporary hut/prefab rooms under Magadh-OCP M-S Are
2024_CCL_318663_1
GM(MS)/SO(EnM)/e-NIT/24-25/52
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Office Of the Project Officer Magadh OCP, M-S Area
Please Refer NIT
4 documents required · 4 mandatory
₹7,580
14 Apr 2025
7 Oct 2024
17 Oct 2024
7 Oct 2024
16 Oct 2024
7 Oct 2024
7 Oct 2024 - 13 Oct 2024
Amount
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling Group A as required.
Replacement metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 250 mm X 60 mm deep as required.
Replacement wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Replacement wire wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Replacement of service wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Replacement of 5 amps to 32 amps rating, 240 /415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. Double pole
2+2 way SPN Single door MCB DB for replacement where required
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc.as required 5/6 A
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modularplate etc.as required 15/16 A
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing brass batten/angle holder including connection etc.as
Supplying and fixing 3pin,5A ceiling rose on the existing junction box/wooden block including connections etc. as required.
Overhauling of existing fan including rewinding as required for running of fans in any circumstances in transit camp and Project office.
Installation,testing and commissioning of ceiling fan,including wiring the downrods of standard length (upto 30 cm) with 1.5sq.mm FRLS PVC
Providing of exhaust fan for installing in toilets of rooms 300 mm diameter for replacement where required
Installation of exhaust fan in the existing opening,including making good the damage, connection, testing, commissioning etc. as required.
12 watt Led Bulb for Replacement in rooms and offices
Manpower supply for Day to Day work Wireman category for (1 Day X 52 Weeks)=52 Days
Manpower supply for Day to Day work Khallasi category for (1 Day X 52 Weeks)=52 Days
Fixing of item no.7,17@15%
Total impact of GST for the purpose of CTC
M/S BABA & CO
M/S T K ENTERPRISES
M/S ELECTRO COOL
M/s KASHYAP ENTERPRISE
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_330289.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .