| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.5 L+₹48,030 (2.00%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹25.3 L+₹1.3 L (5.34%)Rejected-Finance RAJEEV NAGAR KUTIA GHUSIYANA KHARIKA TELIBAGH LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | L3 | Rejected-Finance Being Higher Bidder | |
| 4 | L4₹25.4 L+₹1.5 L (6.13%)Rejected-Finance NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L4 | Rejected-Finance Being Higher Bidder | |
| 5 | L5₹27.0 L+₹3.0 L (12.6%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L5 | Rejected-Finance Being Higher Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Dec 2022, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
CLEANING OF OH TANK, UG SUMP, OTHER MISC WORK AT DIFFERENT PUMP HOUSES INCLUDING REPAIR/REPLACEMENT OF AUTOMATION SYSTEM IN THE AREA OF AGE E/M EXT (WS) UNDER GE E/M LUCKNOW
2022_MES_566206_1
GE/EM/LKO/EXT(WS)/T-58 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹80,000
Yes
11 Jan 2023
30 Nov 2022
28 Dec 2022
30 Nov 2022
26 Dec 2022
14 Dec 2022
Amount
Wash out complete water by pumping set/manually of existing Underground sump/ static water tank up to 50000 gallons capacity including removing deposited sand from inside the tank, scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus deposits stains using wire brush, filling of cavaties inside of tank with CM 1:1 with quick setting cement and applying two coat of white wash inside & writing date of cleaning complete all as specified and directed. Note:- (i) All type of T & P, Labour & pumping set etc shall be arranged by the contractor and rate for the same will be deemed to be included in the quoted rate. (ii) Contractor will dispose off the material taken out from the sump at a distance upto 50 Mtr complete all as specified and directed. (iii) Contractor will clean the surroundings of Tank upto 3 mtr around the plinth of the tank.
All as per item No 01 above but capacity upto 100000 GLNS
All as per item No 01 above but capacity upto 200000 GLNS
All as per item No 01 above but capacity upto 400000 GLNS
Cleaning inside RCC OH reservoirs capacity 375000 gallons at 22 metre staging including removing deposit sand from inside the tank scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus deposits starins using wire brush filling of cavaties inside of tank with cm 1:1with quick cement and applying one coat of white wash inside including dome & writing date of cleaning complete all as specified and directed including repair to wash out system if required for proper flushing of over head tank, complete all as specified and directed. Note :- (i) All type of T&P and Labour etc shall be arranged by the contractor and rate for the same will be deemed to be included in the quoted rate. (ii) Contractor will dispose off the material taken out from the Tank at a distance upto 50 Mtr complete all as specified and directed. (iii) Contractor will clean the surroundings of Tank upto 5 mtr around from the plinth of the tank.
All as per item No 05 above but tank capacity 100000 gallons
All as per item No 05 above but capacity up to 50000 gallons
All as per item No 05 above but capacity up to 25000 gallons
M&L in repair aviation Light fitting 100 Watt 230 Volts 50 Hz yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories, complete all as specified and directed.
S&F in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240V,of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 02 way complete all as specified and directed.
S&F in repair MCB single pole & neutral 16 Amps rating, 'C' Series, 10 KA, 240 Volt complete all as specified and directed.
Supply and fixing PVC insulated & sheathed , heavy duty electric cable on RCC Piller /Dome of over head tank at hight of 25 meter approximatelly from normal ground level incluiding fixing arrangement with Copper conductor, multi stranded 1100 volts grade Flate 2 core 04 Sqmm and taking out of existing unserviceable cable complete all as specified and directed.
Supply & replacement of DOL starter for single phase motor, 220 V upto 3 HP Motor complete all as specified and directed.
Supply & replacement of DOL starter for three phase motor,440 V 5 HP Motor complete all as specified and directed.
S&F in replacement cast iron Sluice valve PN-1.6 flanged ends suitable for 150 mm bore, ISI Marked, conforming to IS-14846/2000 with stainless steel spindle and including jointing material complete all as specified and directed.
Painting of pipe lines with two coat of synthetic enamell paint as per colour code after cleaning and removing existing dust and dirt on existing painted surfaces of 200 mm bore vertical with over head tanks from GL upto 21 Mtr above GL complete all as specified and directed. (Note :The rate for scafolding etc deemed to be included in the quoted rates.)
All as per item No 16 above but 150/100mm bore vertical with over head tanks from GL upto 21 Mtr above GL
All as per item No 16 above but 150/200 mm bore horizontal pipe along with Sluice valve/ NRV at GL for header/inside/Outside of Pump House
All as per item No 16 above but 100/80 mm bore horizontal pipe along with Sluice valve/ NRV at GL for header/inside/Outside of Pump House
S&F in repairs single phase preventor to prevent against single phasing, reverse phasing with wiring & testing, complete all as specified and directed.
Supply and fixing only in replacement of the water level indicator of OHT 21 head and 90 mtr apart from the tubewell complete kit in all manners including taking down of old unserviceable spares complete all as specified and directed.
Laying, fixing, jointing and testing of solid PVC insulated , 10 pairs, individual shielded for interference rejection, armoured PVC sheathed 1100 Volts garde 0.5 sqmm instruemental cable ISI-5608 marked ,complete all as specified laid in trenches/ laid under floor with and including taking out unserviceable cable complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items.
All as per item No 22 above but fixed on dome/pillar of RCC overhead tank
S&F cable joint kit suitable for 0.5 Sq mm 10 pairs of copper wire cable of water level indicator complete all as specified and directed.
Repair to pipe line inside the RCC OH reservoir at an approx height 25 Mtr above the normal GL including taking down UNSV pipe for Cutting in position 150 mm bore CI /DI pipe class 'B' /K-9 (Approx 3 Mtr) complete all as specified and directed.
Supply & fixing in true vertical position DI pipe 150mm bore k-9 including taking down of existing pipe complete all as specified and directed.
M&L in replacement CI Special as per site requirement, complete all as specified and directed.
Attending complaint to make automation system functional of 16 Nos pump houses (servicing and management distribution network) installed at various location at Lucknow cantt including replacement of mechanical/electrical/electronic parts and components of PLC based control panel complete all as specified and directed. (Note :- (i) Work requisition as per Annx I duly signed by all concerned kept on record and shall be submitted to GE alongwith RAR. (ii) Spare parts upto cost of Rs. 50.00 shall be included in the unit rate quoted by the bidder. (iii) Any other spare parts shall be measured and paid separately under appropriate items. (iv) Complaint shall be recitifed within 48 Hours from the date of complaint, failing which recovery shall be charge @ Rs. 50.00 per complaint per day. (v) Maintenance daily under supervision of Engr-in-Charge.)
Supply only Relay -4 PDT, 240V AC, 3A complete all as specified and directed.
Supply only Relay - 4 PDT, 24V DC, 3 Amp complete all as specified and directed.
Supply only Relay Port-4 closed/ open, 220V AC/ 24V DC complete all as specified and directed.
Supply only LED indicator lamp 230V AC/ 24V DC of colour Red/ Yellow/ Green complete all as specified and directed.
Supply only push button with LED indicator with NO & NC contact 240 V AC, color : Red / Yellow / Green complete all as specified and directed.
Supply only of SMPS input volt 230V AC, Output volt 24 V DC and output current 3 Amp complete all as specified and directed.
Supply only of Limit Switch for Actuator Suitable for 80 mm /100mm/ 150mm /200mm dia size with 1 NO & 1 NC, 2 Amp complete all as specified and directed.
Supply only expansion adopter/ input card and output card having min 8 digital input & 8 digital output for PLC (programmable logic controller), complete all as specified and directed. Make : Unitronics / Allen Bradley / Siemens / Mitsubishi.
Supply only Handwheel for 80mm/100mm/150mm/200mm Actuators complete all as specified and directed.
Supply only Magnetic Float level sensor complete all as specified and directed.
Supply only Water Level Controller Relay Card (05 levels), having input volt 12 V DC & output 5V DC, 0.25 Amp rating complete all as specified and directed.
Supply only step down transformer input 230 V AC,Output 12V DC, 2 Amp rating complete all as specified and directed. Make:- AIM
M & L in replacement of old burned wire with panel wiring using PVC insulated 0.5 Sqmm copper wire complete all as specified and directed.
Servicing of motorised Butterfly Valve of sizes 80 mm /100 mm/150mm i.e. removing , cleaning ,greasing, refixing and recommissioning for wear & tear complete all as specified and directed. (Note:- Spares shall be measured and paid separately if needed).
Servicing of motorised Butterfly Valve of sizes 250 i.e. removing , cleaning ,greasing, refixing and recommissioning for wear & tear complete all as specified and directed. (Note: Spares shall be measured and paid separately if needed).
S & F in replacement of Actuator Adoptor with key for 150 mm dia butterfly Valve complete all as specified and directed.
S & F in replacement Electric motor of 60 rpm, 1.8 degree straight angle, single phase, 0.45 Amp suitable for Actuator for 100 mm dia butterfly Valve complete all as specified and directed.
S & F in replacement Electric motor of 60 rpm, 1.8 degree straight angle, single phase, 0.45 Amp suitable for Actuator for 150 mm dia butterfly Valve complete all as specified and directed.
S & F in replacement Electric motor of 60 rpm, 1.8 degree straight angle, single phase, 0.45 Amp suitable for Actuator for 250 mm dia butterfly Valve complete all as specified and directed.
Supply in replacement, Installation, testing & commissioning of flow/ pressure switch 1-10Kg/Sq cm, input volt 24V DC in replacement alongwith all necessary installation accessories like wiring, GI barrel piece, double nipple etc, complete all as specified and directed.
Supply in replacement, installation, Testing & commissioning PLC having minimum 12 inputs and 9 transistor outut with inbuilt power supply and HMI, 24V DC auxiliary supply complete all as specified and directed.
Supply & fixing in replacement six core, 1.5 sqmm nominal cross sectional area, multistranded armoured copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVC sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified and directed.
Supply & fixing in replacement four core, 1.5 sqmm nominal cross sectional area, multistranded armoured copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVC sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified and directed.
Supply & fixing in replacement five pair, 0.5 sqmm nominal cross sectional area mulistranded copper conductor cables, PVC insulated and armoured PVC sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified and directed.
All as per item No 52 above but fixed on dome/pillar of RCC overhead tank
S&F cable joint kit suitable for 0.5 Sq mm 5 pairs of copper wire cable of water level indicator complete all as specified and directed.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc .5m above the starting point complete all as specified and directed.
Supply and spread fine dry sand locally available for cable cushioning complete all as specified and directed.
M&L for laying fly ash bricks as per IS 12894 -2002 in trenches as cable protection covers across the length of the cable complete all as specified and directed.
Supply, Installation, Testing and commissioning of motor actuated butterfly valve in replacement with the following specifications including all accessories mentioned as under (a) Valve size 250mm dia (b) Designed line pressure 4 kg/Sqcm (c) Operating Angle : 90 degrees (d) Disc material CI with nylon coating (e) Limit switches : 02 Nos for open and close (f) Mounting : Splash proof-Direct on valve (g) Input Supply : 230V, AC, 50 HZ (h) In built wireless modem compatibility for remote communication (j) Valve position indication with an output of 4-20m A (k) The actuator should be capable of accepting 4-20m A of input of regulating purposes (l) Mannual Operation : Hand Wheel
Supply, Installation, Testing and commissioning of motor actuated butterfly valve replacement with the following specifications including all accessories job mentioned as under (a) Valve size 150mm dia (b) Designed line pressure 4 kg/Sqcm (c) Operating Angle : 90 degrees (d) Disc material CI with nylon coating (e) Limit switches : 02 Nos for open and close (f) Mounting : Splash proof-Direct on valve (g) Input Supply : 230V, AC, 50 HZ (h) In built wireless modem compatibility for remote communication (j) Valve position indication with an output of 4-20m A (k) The actuator should be capable of accepting 4-20m A of input of regulating purposes (l) Mannual Operation : Hand Wheel
Surface dressing & Cleaning away all grass vegetation, sapling, shrubs, brush wood , udergrowth, roots and trees not exceeding 30 cm girt ( measured one meter above ground level) and removing rubbish upto a distance of 50 mtr outside pheriphery of the area under clearnece except in the case of surface dressing which incldues for all the foregoing except clearing away of trees only for MES installations as maintain by DEL complete all as specified and directed.
Spectrum Enterprises
NAVJYOTI ENTERPRISES
NEXT POWER ENTERPRISES
GIAN ENGINEERS
M/S S.B. Singh and Sons
M/S SWATI CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .