Shri M S Bansode IDSE CWE
Commander Works Engineers No. 2, Brichgunj, Sri Vijaya Puram - 744 103
Comprehensive BR EM repairs and maint to certain Bldgs at Naval Detachment Shaheed Dweep Neil Island under AGE I Central, Sri Vijaya Puram
2025_MES_738576_1
80422
Open Tender
Civil Works
Item Rate
270 days
Sri Vijaya Puram
Class E Category a i
9 documents required · 9 mandatory
₹500
Asst Garrison Engineer I Central
₹32,000
Yes
12 Nov 2025
12 Nov 2025
24 Dec 2025
12 Nov 2025
18 Dec 2025
26 Nov 2025
12 Nov 2025 - 19 Nov 2025
S & F 2nd class Handwood plain solid straight chowkats and frames,wrought, framed rebated on the solid rounded or chamfered put together with glue pinned joints as specified and directed by Engr-in-Charge.
M & L for plain cement concrete type C2 1:3:6 (40mm graded aggregate) to fix hold fast complete as specified and directed by Engr-in-Charge.
M&L 15 mm thick cement plaster in CM (1:6) on fair faces of brick work incl finished even and smooth without using extra cement complete as specified and directed by Engr-in-Charge.
S&F aluminium anodised Brackets for tubular curtain rod complete complete all as specified and directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/semicorrugated sheet 0.50mm thick as per approved profile, coloured, having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed by Engr-in-Charge.
Taking down of existing partitions of aluminium alloy sections with glass panels and removal from site , complete all as specified and directed by Engr-in-Charge.
M&L for 10 mm thick frosted toughened glass with SS patch fittings as brackets cleats etc as in partitions , complete all as specified and directed by Engr-in-Charge.
S&F in repairs Handle lock for doors Dorset with a set of 3 keys Backset 60mm complete all as per sample , complete all as specified and directed by Engr-in-Charge.
S&F in repairs Dorset DC 65CO concealed type door closer with in built hold open arm feature for doors of wt upto 65Kg silver finish all as specified and directed by Engr-in-Charge
S & F in repairs Glass Shelf Model Jaquar ACN-1171N or equivalent as per makes in PS 600 mm long , complete all as specified and directed by Engr-in-Charge.
S & F in repairs Stainless Steel Towel Rack Model Jaquar ACN-1181FHS 600 mm size or equivalent as per makes in PS , complete all as specified and directed by Engr-in-Charge.
S & F in repairs Toilet Roll Holder Model Jaquar ACN-1155S Stainless Steel or equivalent , complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all as specified and directed.
S & F in repairs Double Coat Hook Model Jaquar ACN-1161N or equivalent as per maakes in PS, complete all as specified and directed by Engr-in-Charge.
S & F in repairs Model Jaquar ACN-1193N Double Arm Wall Mounted Reversible Plain / Magnifying (X3) Pivotal Mirror as per makes in PS , complete all as specified and directed by Engr-in-Charge.
S & F in repairs Towel Ring Model Jaquar AKP-35721P or equivalent as per makes in PS , complete all as specified and directed by Engr-in-Charge.
Taking down of existing ceiling fans, opening / dismantling of fan & fan blades, cleaning, servicing,oiling, greasing, carrying out repairs such as replacement of burnt Copper Winding, capacitors, bearings, bushes, canpoy, condensor, clamp, safety pin, rubber bush and reassembling the fan & fan blades,, connecting up, testing and re-fixing of the same ceiling fan of any sweep including provision of new cable from ceiling rose/ connector to fan and spray painting of ceiling fan with two coats of synthetic enamel paint after prepartion of surfaces,complete all as specified and directed by Engr-in-Charge (For Single Phase Induction Type Motor Ceiling Fans)
M & L for point wiring complete with proper colour coding using 1100 volts grade, 1.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn Completely in and including PVC casing caping fixed on the surfaces of Walls/RCC slab/ ceiling/columns/beams etc with all accessories, fittings, also inclduifng 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one light point/fan point controlled by one one way switch, complete all as specified and directed by Engr-in-Charge.
-ditto- all as per item No 111 above but for one 3 pin switch socket 5 Amp single pole one way on same board with other switches including continuous 1.5sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
-ditto- all as per item No 111 herein above but for one 3 pin switch socket 5 Amp independent complete all as specified and directed by Engr-in-Charge.
-ditto- all as per item No 111 above but for 3 pin switch socket outlet 15 Amp independent with cable 2.5 sqmm unsheathed stranded 1100 Volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
-ditto- all as per item No 111 above but for 3 pin switch socket outlet 15 Amp independent with cable 4.0 sqmm unsheathed stranded 1100 Volts grade complete with 4.0 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of switch modular type 6 amp single pole one way 230 V complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of switch modular type 16 amp single pole one way 230 V complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of socket outlet multi purpose 5 pin 6 Amp modular type complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of socket outlet multipurpose 3 pin 16 Amp and 3 pin 6 amp modular type 2 in 1 complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of ceiling fan regulator modular type 120 watts complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of ceiling rose surface backelite three terminal complete complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement Modular white cover plate with frame 8 Module complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement Modular white cover plate with frame 6 Module complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement Modular white cover plate with frame 3/4 Module complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement modular Plastic Surface PVC box 6/8 Module complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement modular Plastic Surface PVC box 3/4 Module complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of unservicable Ceiling fan/Exhaust fan capacitor 2.5 micro farad complete all as specified and directed by Engr-in-Charge.
M&L in repair for sub main wiring two run of size 2.5 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 2.5 sqmm PVC insulated copper conductor earth wire in PVC casing caping of suitable size (three run of 2.5 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and directed by Engr-in-Charge.
M&L in repair for sub main wiring two run of size 4 sqmm PVC insulated electric power FRLS cable (heavy duty) 1100 volts grade with stranded copper conductor with 4.0 sqmm PVC insulated copper conductor earth wire in casing caping of suitable size (three run of 4 sqmm cable and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement surface mounting slim/Box tyoe LED flat panel 2' x 2' LEDs 36/40 watts inlcuding replacement of unserviceable LED Drivers and Multistrip LEDs Suitable to Fitted on False ceiling by cutting to complete all as specified and directed by Engr-in-Charge.
Supply and fixing integrated sleek extruded LED channel with acrylic cover 20 watt with white light including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply and fixing integrated sleek extruded LED channel with acrylic cover 10
watt with white light including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and directed by Engr-in-Charge.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of LED lamp with acrylic cover 14 watt Pin or threaded type complete all as specified and directed by Engr-in-Charge.
Supply and fixing round/Square shape 12 watt 230 volts AC recessed type down light with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with 03 core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fix MCCB 63 Amps 3 Pole, with breaking capacity 16 KA along with spreader terminals including replacement of old unservceable one complete all as specified and directed by Engr-in-Charge.
Supply and fix sheet metal enclosure powder coated for MCB DB SPN 12 way double door vertical type with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and directed by Engr-in-Charge.
Supply and fix sheet metal enclosure powder coated for MCB DB SPN 4 way double door vertical type with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and directed by Engr-in-Charge.
Supply and fix MCB SPN 240 volts 6 to 32 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed by Engr-in-Charge.
Supply and fix MCB SP 240 volts 6 to 32 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed by Engr-in-Charge.
Taking out split type air conditioner (both indoor and outdoor units) of capacity upto 1.5 TR of any Make/type after disconnecting refrigerant pipes, drain pipe and electric connection and removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda, checking and replacing the spares like PCB, relay, All type of capacitors, thermostat, fan motor, blades & blower and including servicing, overhauling and connecting of refrigerant pipe,drain pipe and charging of refrigerant and testing including fixing back in its original location complete all as specified and directed by Engr-in-Charge. Note : (i) Spares such as PCB,Fan Motor,Blower are exclusive of Quoted rate.
M&L for Charging of refrigerant Gas R-32 in split type Air conditioner (All weather) of capacity 1.5/2 Ton after flushing the complete system with CTC (Carbon tetra choloride) including S & F and replacement of filter/stainer and capillary, vacumise the complete system with vacuum pump and testing on after charging gas complete all as specified and directed by Engr-in-Charge.
S& F in replacement of PCB for inverter Type AC with remote control for Split type AC (All weather) of cap 1.5/2 TR as per existing makecomplete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of U/s DOL starter for Three phase Monoblock Centrifugal pump suitable to upto 10.0 HP motors for soft starting the three phase Machine complete all as specified and directed by Engr-in-Charge.
Supply and laying in repair, galvanised iron, water tubing, medium grade for the pipe 50mm dia, including necessary fittings such as GI bends, Tees, Union etc complete and connecting to water supply pipe line and connections in trenches/passing under roads complete all as specified and directed by Engr-in-Charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
80422ATC.pdf
Tender Documents • 1.16 MB
BOQ_828027.xls
BOQ • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .