Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.9 L+₹3.1 L (7.39%)Rejected-Finance | L2 | Rejected-Finance Not being lowest |
Tender Value
₹38.8 L
EMD Value
₹77,600
Closing Date
16 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE 860 EWS
PROVN OF ONE GUARD ROOM WITH ATTCHED BATROOM WITH SENTRY POST FOR 2254 FIELD HOSPITAL AND ONE GUARD ROOM WITH ATTCHED BATHROOM WITH SENTRY POST FOR CERTAIN UNITS AT NYOMA UNDER GE 860 EWS
2022_MES_533718_2
8155/E8/2022-23
Open Tender
Civil Works
Item Rate
270 days
NYOMA
Class D Category a (i)
9 documents required · 9 mandatory
₹500
GE 860 EWS
₹77,600
Yes
6 Sept 2022
30 Jul 2022
18 Aug 2022
30 Jul 2022
16 Aug 2022
4 Aug 2022
Amount
Surface dressing n.exc. 15 cm deep in soft/loose soil complete all as specified and directed
Excavation in tranches n. exc. 1.5m wide and n. exc. 1.5m depth for foundation and getting out in loose/ soft soil complete all as specified and directed
Excavation over areas n exc 1.5m deep and n exc 10 sqm on plan getting out in hard dense soil complete all as specified and directed by Engr in Charge
All as per item No 3 here in before but n exc 1.5m and n exc 3m in depth
M&L for cement concrete type D2 1:4:8 (40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (design mix) using 20mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and as directed.
M&L form work to sides of concrete foundations, footings, bases of columns raft and beams sides and soffits(if any) of foundations and plinth,beams and similar work,vertical or to batter,for rough finished flat surfaces of concrete complete all as specified and as directed.
M&L form work to sides of pillars, posts, struts, piers, columns and stanchions, for square, rectangular or poygonal, rough finished surfaces of concrete complete all as specified and as directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of concrete complete all as specified and as directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc rough finished surfaces of concrete complete all as specified and as directed.
M&L for formwork Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide rough finished surfaces of concrete complete all as specified and as directed.
M &L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(annealed ) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M &L mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, cut to length, bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(annealed ) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M & L Precast cement concrete block masonry type C1 1:3:6 (20mm graded crushed stone aggregate) with solid blocks, exc. 10cm in width and, setting in cement mortar 1:6 complete all as Specified.
S&F for 2nd Class soft wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed
S&F 35 mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated
S&F 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed
S&F 75 mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed
S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F 150mm Aluminium handles, cast type, anodised complete all as specified and directed
S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed
S&F 300 mm aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed
M&L 4 mm thick glass panes ordinary quality and glazing with oil putty fixed with woodedn beads n exc 0.5sqm in each pane including hacking out old broken glases of any size complete all as specified and directed
S&F of 30mm thick 2nd class hard wood (shisham) glaze and skelton shutters, open rebated and prepared to receive glass gauge etc divided into suqares with plain chamfered or rounded, mittered edges of framing plain, chamfered or rounded complete all as specified and directed by Engr in Charge
M&L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface in broken stone or boulders complete all as specified and directed.
M&L for Cement Concrete type C-2, 1:3:6 (20 mm graded crushed stone aggregate) - 100mm thick as Sub base complete all as specified and directed.
Rendering 15mm thick on fair faces of brick work or concrete sur- faces in cement mortar 1:6 and to be finished even and smooth without using extra cement - Internal Plaster complete all as specified and directed.
M&L for coloured jointless Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm screed bed in CM 1:6 complete all as specified and directed by Engr -in-Charge
M&L for Glazed ceramic tiles 450x300x7mm thick coloured/shaded as in vertical surfaces such as skirting dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the surface
Rendering 15mm thick in Cement mortar (1:4) using water proofing compound as per manufacturer's instruction in two layers, finished even and smooth surface without using extra cement - External Plaster (WPC measured and paid separately) complete all as specified and directed.
Rendering 5mm thick in Cement mortar (1:3) finished even and smooth without using extra cement on ceilings
M&L for preparation of new plastered surfaces and apply two coats of cement base paint complete all as specified and directed.
M&L for preparation surface and apply two coats of oil bond distemper over a coat of primer on newly plastered surface complete all as specified and directed.
M&L for preparation surface and apply three coats of white wash on newly plastered surface complete all as specified and directed.
M&L sand filling under floors including watering and consolidation complete all as specified and directed.
Supply only water proofing compound for external plaster complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in plinth protection complete all as specified and directed
S&F in repair vitreous china squatting Pan of Orrisa pattern 580 mm x 440 mm with integral foot rest white with CI "P" or "S" trap front or back inlet including PCC bedding complete all as specified and directed
S & F of PVC (Plastic polymer Cistern) low level white flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle etc and S & F of 32 mm dia PVC flush pipe of suitable length and making all connection complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed..
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed.
S&F 500 ltr cap Rotational moulded polyethylene water storage tanks tripled layered (cylindrical vertical with threaded closed top) hoisted and fixed in position all as specified and directed by Engr-in-Charge
S&F PVC floor trap 75 mm bore setting and jointing with solvent cement complete all as specified and directed
M&L for PVC (SWR) 110 mm gully trap setting joining with solvent cement complete all as specified and directed.
S&F 20 mm bore Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F 20 mm bore ball valves high pressure PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed.
S&F of 16mm bore 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc
All as per item No 53 above but 20 mm dia pipe
S&F 15 mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe and fixed.
S&F 20 mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F Viterous China wash hand basin with pedestal coloured, flat back of 550 x 400 mm including brackets, cutting for and pinning the ends of brackets or erecting stands also including brass chromium plated waste coupling 32mm dia, PVC flesxible waste pipe of 750mm long complete all as specified and directed
S&F 15mm bore pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified
S&F of 15mm bib taps, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed
S&F PVC connection 15mm size with PTMT nuts of length 450mm fixed complete all as specified and directed.
S&F brass chromium plated tubular towel rail 20mm dia 600 mm long fixed complete all as specified and as directed.
M & L for PCC 1:3:6 type C-2 ( Nominalmix) using 40 mm graded crushed stone aggregate as in foundation filling, mass concrete and similar work complete all as specified and directed by Engr-in-charge.
Walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted, build in cement mortar 1:4 complete all as specified and directed by Engr-in-charge.
Walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted, laid dry complete all as specified and directed by Engr-in-charge.
M/L PCC Type B - 1, 1:2:4 using 20mm graded crushed stone aggregate as in fixing of pipes in vertical and other similar work as required, complete all as specified and directed by Engr-in-charge.
M&L for Precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in manhole's cover slab etc placed in position including necessary form work and set in cement mortar 1:4 complete all as specified and directed by Engr-in-charge.
M&L for broken boulder stone n. exc 63mm of gauge in loose filling complete all as specified and as directed. complete all as specified and directed by Engr-in-charge.
M&L for Rendering 15mm thick, in cement mortar 1:4 on RR masonery surfaces and finished even and fair without using extra cement with water froofing compound complete all as specified and directed by Engr-in-charge.
Plain cement concrete 1:4:8 type D-2 using 40 mm graded aggregate for bed to drain pipes including packing under and haunching against the sides of pipe for 150 mm bore after they are laid and tested ccomplete all as specified and directed by Engr-in-charge.
S&F of 150mm dia reinforced concrete pipes, NP2 laid and jointed complte with collars complete all as specified and directed by Engr-in-charge.
M&L point wiring complete for one light / bell / fan point controlled by one no, 1-way, 5 Amps switch. with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 1.5 Sqmm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & PVC casing and capping of 25 mm and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and incl concealed MS sunken box of suitable size flush with wall surface, covered with & incl 3 mm thick bakelite, laminated hylem sheet / Gang box for top cover suitable for fixing of piano type switches / sockets etc, complete all as specified and directed for the following :- (Note : The cost of MS sunken box with 3 mm thick bakelite, laminated hylem sheet top cover is deemed to be included in quoted rate.)
Al as per srl item no. 71 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board.
All as per srl item no. 71 here-in-before but for one socket outlet 3 pin, 5 Amps on same board.
All as per serial item No 71 here-in-before, but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor (Multi-stranded) insulated and unsheathed electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.50 Sqmm copper stranded conductor as continuous earth wire connected to common dolly complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush button single pole one way 5 Amps complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing socket outlet 2 in 1, 5 Amp, flush type completeall as specified and as directed by Engr-in-charge.
Supply and fixing switch socket combination multi purpose 2 in 1, 3 pin 5A/16A, 5 in 1 flush type complete all as specified and as directed by Engr-in-charge.
Supply and fixing angular lamp holder, PVC/Polycaronate type with back plate suitable for 9 watt LED bulb for batten fittings complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing LED 12 watt complete all specified and as directed by the Engineer-in-Charge..
Supply and fixing ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing LED batten lights fitting 1x 20W, 220V,AC decorative type including LED tube light connecting up with three core flexible copper conductor cable of suitable size including ceiling rose complete.
S&F DB, Single Door, made out of CRCA mild steel sheet surface with insulated material like polyester or With epoxy powder coating and IP 43 & IK 09 protection, SPN 8 way, 240 volts with bus bar rating 200 Amps dust and vermin proof, suitable for incorporation of MCB's and isolators etc and making ll necessary connections, duly flush of wall surface, complete all as specified and directed.
Supply and fixing MCB single pole and neutral 32 to 40 Amps, 240 volt, 10 KA, complete all as specifed and as directed by Eng-In-Charge
Supply and fixing MCB single pole 5 to 30 Amps, 240 volts, 10 KA complete all as specified and as directed by the Engineer-in-Charge.
M&L for sub main wiring with 2 run of 4 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate, ISI marked, non metallic PVC casing Caping 15 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note : 1. The cost of conduit & accessories is deemed to be included in quoted rates. 2. The 2 run of 4 Sqmm wire and one run of 4 Sqmm wire will be measured as one unit.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all specified and as directed by the Engineer-in-Charge..
Supply and fixing new energy saving LED Bulk head fitting 12 watt made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK07 as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Eng-In-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to CBDB’s as specified or indicated including testing on completion .
Supply and laying XLPE insulated, armoured, heavy duty electric cable, with stranded aluminum conductor 1100 V grade nominal cross sectional area 16 Sqmm, 2 core laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-Charge
Excavation in trenches not exceeding 1.5m and not exceeding 1.5m in depth for laying of electric cable and getting out in hard and dense soil, complete all as specified and as directed by the Engr-in-Charge.
Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying, streching & testing of cable in trenches complete all as specified and directed by Engr-in-Charge. Note :- Only punned thickness i.e 18cm shall be measured and paid.
M/S Web Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .