Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 441 190 A SIDDIQUI HOUSE MALAPURAM COLONY JAL NIGAM ROAD BALAGANJ LUCKNOW UTTAR PRADESH 226003 | LUCKNOW | UTTAR PRADESH | 226003 | Admitted-Finance |
Tender Value
₹16.3 L
EMD Value
₹16,260
Closing Date
2 Aug 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EWCL
MVVNL, TIPE IV/3, TRANSMISSION STAF COLONY, DEVA ROAD, CHINHAT, Lucknow
MAINTENANCE WORK OF 33 KV SUBSTATION ATRAULI SANDILA RURAL KACHAUNA BENIGANJ NEW AND OLD MALHERA BAGHAULI AND UPSIDC OLD UNDER EDD II AT DISTRICT HARDOI UNDER BUSINESS PLAN 2024 25
2024_MVVNL_939444_1
10/EWCL/2024-25
Open Tender
Electrical Works
Item Wise
90 days
HARDOI
AS PER PQR
2 documents required · 2 mandatory
₹3,540
SE EWCL
₹16,260
27 Aug 2024
19 Jul 2024
2 Aug 2024
19 Jul 2024
2 Aug 2024
19 Jul 2024
Amount
Dragging, loading, carriage and unloading of following store material with proper stacking from ESC Hardoi to JE's dump store and from store to work site:
Cost of 33 KV line Isolator
Cost of 33 KV Bus Isolator
Cost of Post Insulator
Cost of 33 KV Lightening Arrester
Cost of 33 KV VCB 800 Amp., 750 MVA
Cost of 33 KV CT 200/100/1 Amp.
Cost of 33 KV Single T/F Control Pannel with structure.
Cost of 33 KV Double T/F Control Pannel with structure.
MS Channel 125x65, 3.2Mtr. Long 1,2,3,4 No Pieces for Top channel. 13.10 Kg/Mtr.+wastage.
MS Angles 50x50x6mm for bracing type members of T.G./B.G./Trench
MS Angles 75x75x8, 2.6mtr long, total 5.2 @ 8.9 Kg/Mtr.
Cost of ACSR Panther Conductor
Plinth of VCB : Construction of Plinth of size 2.0 mtrx1.5mtrx0.9mtr. suitable for erection of upper structure of 33KV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base and concreting in CC 1:3:6 (cement, find sand & stone grit) 1st class brick work in cement mortor ratio 1:4:8.
Repairing and Replacement of 33 KV existing Bus bar with the help of PG Clamp, Isolator Clamp, and CT Connctector. All material provided by contractor except PantherConductor.
Replacement of all connection of existing of 05/10MVA Transformer with the help of Bimetallic clamp.All material provided by contractor except panther conductor.
Repairing & plastering of existing 5/10 MVA T/F plinth , as per RESPO Norms.
Installation of VCB: Installation of 33KV VCB complete work with making earth connections(Earth Mat/earthing) with GI Strip 50x6mm including control wiring, commissioning & testing (All decentralised materials to be provided by Contractor).
Installation of Isolators: Assembling and installation of line isolator on the existing isolator structure adjusting of opening mechanis in proper alignment so as to ensure smooth operation of the same. In case of line isolator proper operation of earth links shall also be ensured. The work includes fabrication & proper connection with earthmat by G.I. erth strip 50x6mm for proper flexing if required.
Installation of Lightening Arrestors ,PI: Assembling, installation & mounting of 10 set L.A.. Structure/complete with making earth connections (separate) and line connections. The work includes fabrication for fixing if required.
Installation of CT: Installation of 33No.(11 set) CT on the CT Structure along with CT Junction Box. The work includes fabrication for proper fixing of C.T. If required and proper commissioning & testing.
Earthing for power T/F & other structures by way of boaring and lowering of 40mm dia, 2.9 mm thick GI Pipe from ground upto the water level (minimum 60 feet deep) as per standard practice and REC Drg.
Earthing of 33 KV Switchgears equpiment by lowaring and boring of Chemical Earthing outside of switchyard and connecting through G.I. Strip 50x6mm with indoor/outdoor equipments with making of earth pit of 300x300 mm & 1 feet deep with Cover. (All the material provided by the contractor)
Supply and laying of following size Copper Control Cable through underground/cable trench/trenching SGR interlinking through proper connections to T/F Control panel/protection board/Battery and Battery Charger/Bunch joints, Relay 33/11KV T/F junction Box/33KV VCB, CTs etc. as per site conditions:
6x2.5 Sq.mm
4x2.5 sq.mm
2x2.5 sq.mm
Supply & Fixing of control cable Trey
Painting of all structures and equipments.
Repairing and Extension of Existing Damage Wiremesh fencing of Sub Station With Gate & ToeWall.
Shifting carefully and installation of 33KV Single/Double Transformer /FeederControl Panel in Control Room including fixing, bolting & grouting of above as per required and testing, commisioning complete work as per required.
Supply & Installation of 24 VOLT Battery & it's Charger with connection to existing control circuit comp. in all respect.
Repairing & plastering of existing CT,Isolator,P.I.,LA,Structure Foundation on each Sub Station , as per RESPO Norms.
Repairing,servicing& Maintaince of Diffective 33 KV VCB ON existing different Sub Stations
Re-arrangement & Repairing of Existing 33 KV VCB & CONTROL PANNEL structure with control panel connection And Proper Testing in all respect(All the material provided by the contractor)
M/S AARADHYA AND ADHYATM ASSOCIATES
A.A. ENGINEERING CO.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .