| Sl No | Description | Qty | Unit | M/s. ADITYA TRADING CO., KM-383, RAIDOPUR OFFICERS COLONY, AZAMGARH, U.P.-276001. L2 | M/s. ADITI CONSTRUCTION, RAHUL NAGAR MADYA, AZAMGARH, U.P.-276001 L4 | R.T.K POWER ENGINEERS L3 | INDIAN ENGINEERING WORKS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Following detailed work is to be done different 132 KV Sub Stations under ETD-II, Jaunpur | |||||||
| 2.00 | Overhauling and Servicing of 82.5 KVA DG set at 132 KV S/S Siddiquepur by checking accessories drive , bearing cylinder head , cylinder liner, front gear train and rear gear train, lubricating ,oil pump, piston, connecting rod, piston ring, crankshaft journals, camshaft. Cum follower, Accessories drive seal, Front and rear crankshaft seals and oil cooler, replacing 12 volt battery set for smooth to complete the job satisfactory.
Note. All consumable material and spares will be provided by the contactor and except 12 volt battery. | 1 | No | 18,999 ₹18,999 Lowest | 19,075 ₹19,075 | 33,000 ₹33,000 | 30,000 ₹30,000 |
| 3.00 | Erection of ACDB panel at ACDB room as per instruction manual of panel. The work contain safe carriage of panel from store to site and to be erected on trunch including modification of trunch as per panel foundation by cutting welding of MS angle/channel and other assocaited work to complete job satisfactorily. | 1 | No | 7,320 ₹7,320 | 7,320 ₹7,320 | 7,000 ₹7,000 | 6,500 ₹6,500 Lowest |
| 4.00 | Delta Earthing for panel and trunches of ACDB room with MS flats the work contain fabrication three no. 3 meter long electrode of 40 mm dia and place them inside the ground below 300 mm depth from gound level in delta formation connect all three electrods with 75x10mm size MS flat by welding then connect the same to ACDB panel and trench with size 50x6 and 25x6 respectively Note- Flat & rod shall be provided by department and salt and coal shall be provideby contractor. | 2 | Job | 8,320 ₹16,640 | 8,320 ₹16,640 | 8,500 ₹17,000 | 7,000 ₹14,000 Lowest |
| 5.00Laying of power cable of following size 500mm below ground level including excavation of pit and layinh of cable and putting Ist class bricks on its 75mm edge along with cable on both side. Filling the same with ganaga sand and then putting bricks on 115mm crossing side over cable and then filling with earth including cost of brick sand etc and all other associated work to complete the job satisfactorily as per drawing no.at 132 kV S/S Kerakat. | |||||||
| 6.00 | 3.5C x 400 MM2 | 100 | Rmt | 225 ₹22,500 | 225 ₹22,500 | 240 ₹24,000 | 220 ₹22,000 Lowest |
| 7.00 | 3.5C x 50 MM2 | 200 | Rmt | 160 ₹32,000 | 200 ₹40,000 | 150 ₹30,000 | 130 ₹26,000 Lowest |
| 8.00Termination of following size of powe rcable of providing proper size of alluminium Dowel/Jonsion make lugs its crimping and connecting with equipment including cost of lugs and all other associated work to complete satisfactroy. | |||||||
| 9.00 | 3.5C x 400 MM2 each end | 4 | No | 1,799 ₹7,196 | 1,799 ₹7,196 | 1,600 ₹6,400 Lowest | 1,700 ₹6,800 |
| 10.00 | 3.5C x 50 MM2 each end | 8 | No | 499 ₹3,992 Lowest | 499 ₹3,992 Lowest | 500 ₹4,000 | 500 ₹4,000 |
Tender Value
₹2.0 L
EMD Value
₹2,000
Closing Date
24 Oct 2025, 4:00 pmClosed
Executive Engineer ETD 2 Jaunpur
132 Kv Sub Station Huainabad Jaunpur
Overhauling and Servicing of DG Set installed at 132 KV Sub Station Siddiquepur and Erection of New ACDB at 132 KV Sub Station Kerakat
2025_UPTCL_1073363_1
13/ETD-II(J)/2025-26
Open Tender
Electrical Works
Lump-sum
Siddiquepur and Kerakat
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
EE ETD 2 Jaunpur
₹2,000
Yes
31 Oct 2025
12 Sept 2025
25 Oct 2025
12 Sept 2025
24 Oct 2025
12 Sept 2025
Amount
Following detailed work is to be done different 132 KV Sub Stations under ETD-II, Jaunpur
Overhauling and Servicing of 82.5 KVA DG set at 132 KV S/S Siddiquepur by checking accessories drive , bearing cylinder head , cylinder liner, front gear train and rear gear train, lubricating ,oil pump, piston, connecting rod, piston ring, crankshaft journals, camshaft. Cum follower, Accessories drive seal, Front and rear crankshaft seals and oil cooler, replacing 12 volt battery set for smooth to complete the job satisfactory. Note. All consumable material and spares will be provided by the contactor and except 12 volt battery.
Erection of ACDB panel at ACDB room as per instruction manual of panel. The work contain safe carriage of panel from store to site and to be erected on trunch including modification of trunch as per panel foundation by cutting welding of MS angle/channel and other assocaited work to complete job satisfactorily.
Delta Earthing for panel and trunches of ACDB room with MS flats the work contain fabrication three no. 3 meter long electrode of 40 mm dia and place them inside the ground below 300 mm depth from gound level in delta formation connect all three electrods with 75x10mm size MS flat by welding then connect the same to ACDB panel and trench with size 50x6 and 25x6 respectively Note- Flat & rod shall be provided by department and salt and coal shall be provideby contractor.
Laying of power cable of following size 500mm below ground level including excavation of pit and layinh of cable and putting Ist class bricks on its 75mm edge along with cable on both side. Filling the same with ganaga sand and then putting bricks on 115mm crossing side over cable and then filling with earth including cost of brick sand etc and all other associated work to complete the job satisfactorily as per drawing no.at 132 kV S/S Kerakat.
Termination of following size of powe rcable of providing proper size of alluminium Dowel/Jonsion make lugs its crimping and connecting with equipment including cost of lugs and all other associated work to complete satisfactroy.
3.5C x 400 MM2 each end
3.5C x 50 MM2 each end
Dismantling of old 36 KV LSI and BSI of 33 KV BAJRANG NAGAR FEEDER and BSI of 40 MVA T/F 1st LV side at 132 KV S/S KERAKAT. The job includes opening of all jumpers Dismantling of operating mechanism and earthing . dismantling of above isolator by opening nuts & bolts and lowering the 36 KV old isolators from structure and shifting from switchyard to out side store to complete the job satisfactorily .
Erection of New 36 KV LSI and BSI of 33 KV BAJRANG NAGAR FEEDER and BSI of 40 MVA T/F 1st LV side at 132 KV S/S KERAKAT. The job includes shifting of new 36 KV isolators from store to site and erection of new isolator as per instruction manual and technical specification , proper tightening of nut & bolts and make jumpers all sides. and its proper earthing to complete the job satisfactorily . NOTE:- All Men & T&P required for the completion of job will be provided by the contractor his own cost.
M/s. ADITYA TRADING CO., KM-383, RAIDOPUR OFFICERS COLONY, AZAMGARH, U.P.-276001. (BID ID -5593954)
R.T.K POWER ENGINEERS (BID ID -5598233)
M/s. ADITI CONSTRUCTION, RAHUL NAGAR MADYA, AZAMGARH, U.P.-276001 (BID ID -5610710)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
PartIT13.pdf
Tender Documents • 0.37 MB
BOQ_1959390.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .