Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.1 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹20.0 L+₹1.5 L (8.32%)Rejected-Finance | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹21.8 L+₹3.4 L (18.6%)Rejected-Finance | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹24.8 L+₹6.4 L (34.7%)Rejected-Finance BATWARA SRINAGAR KASHMIR 190004 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-4 | Rejected-Finance other than L-1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Jun 2023, 6:00 pmClosed
Maj. Sujith Mohan, GE
Garrison Engineer 864 Enggr Wks Sec, PIN-913864,C/o 56 APO
Repair/maintenance of fencing, gate, compound wall, drain/drain cover, hume pipe ,culverts and sewage line etc in Zone A at BB Cantt Srinagar
2023_MES_595080_1
864/WS-25/2023-24
Open Tender
Civil Works
Item Rate
335 days
B B Cantt.
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹50,000
Yes
11 Jul 2023
12 May 2023
10 Jun 2023
12 May 2023
8 Jun 2023
26 May 2023
Amount
Demolition of brick work or stone masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete 100mm dia (internal bore) and removing of demolished pipe to a distance exceeding 100m and depositing as complete all as specified and directed .
Description all as per srl item No. 3 above but 150mm dia complete all as specified and directed .
Description all as per srl item No. 3 above but 200mm dia complete all as specified and directed .
Description all as per srl item No. 3 above but 300mm dia complete all as specified and directed .
Dismantling wrought iron or mild steel work of any description not other wise provided, Complete all as specified and directed.
M&L cutting into existing manholes for connecting new drains of 150mm dia internal bore) making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate smooth finished and reforming benching as required complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for fdn for shafts, cills, cesspits, manhole pier holes not exc 10Sqm on plan and getting out in hard/dence soil complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide , exc 1.5 m and not exceeding 3m in depth for fdn for shafts, cills, cesspits, manhole pier holes n.exc 10Sqm on plan and getting out in hard/dense soil, complete all as specified and directed.
M&L for Plain cement concrete 1:3:6, type C-2 using 40 mm aggregate stone aggregates as in foundations, filling and mass concrete, complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers n.exc 25cm thick in hard / dence soil complete all as specified and directed.
Removing of excavated soil to a distance not exc 50m and depositing where directed by the Engr-in-Charge at a level not exc 1.50m above the starting point complete all as directed
M&L for Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4, complete all as specifed and directed.
M&L for Plain cement concrete 1:2:4 type B1, using 20mm graded stone aggregate as in coping etc including weathering, slightly rounded or chamfered angle and throating, necessary form work, complete all as specified and directed.
M&L for rendering 10mm thick on fair face of brick work or concrete surface in cm 1:4 all as specified finished even and smooth without using extra cement, with using water proofing compound 3% by weight of cement, complete all as specified and as directed. Note :- WPC shall be measured and paied seperately
M&L for rendering 15mm thick on other than fair face of brick work in cm 1:4 all as specified finished even and smooth without using extra cement, with using water proofing compound 3% by weight of cement, complete all as specified and as directed. Note :- WPC shall be measured and paied seperately
Supply only Integral Water Proofing Compound and used as per manufacturer instruction
M&L for cutting of road as required (approx 9.25m each length) for laying RCC pipe line including repair/make good with filling of earth, boulders, WBM, BM etc. with top surface finished with 30mm thick ready mixed patch filter, complete all as specified and as directed.
S & F PVC (SWR) 110 mm pipes single socketed, in any length with rubber ring joints, laid in trenches or on wall complete all as specified and directed.
S&F 150 mm dia reinforced concrete pipes, class NP2 with collar per length of pipe laid in trenches complete all specified and directed.
Description all as per item No 21 above but 200mm dia complete all as specified and directed.
Description all as per item No 21 above but 300mm dia complete all as specified and directed.
M&L Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in concrete bed to drain pipes 150mm internal bore including packing under and hunching against the sides of pipes after they are laid and tested, in complete all as specified and directed.
Description as per srl item No. 24 aboive but 200mm dia complete all as specified and directed.
Description as per srl item No. 24 aboive but 300mm dia complete all as specified and directed.
M&L pre-cast RCC 1:2:4 type B1 using 20mm graded stone aggregate as in cover slab for manhole etc including necessary form work complete all as specified and directed.
TMT mild steel bars, 8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed .
M&L for Framed work such as in angle iron frames for manhole covers and similar work confirming to Fe 290 grade E-165 complete all as specified and as directed.
M&L for Mild steel round bars 10mm dia as in handles for manhole cover complete all as specified and directed.
M&L for cleaning of CI/PVC pipe of any size laid in trenches including bends/junctions/ gully traps etc and removing of sludge if any to a distance exc 50m and depositing as directed by at site complete all as specified and directed.
Description all as per item No. 31 here-in before but fixed to wall complete all as specified and directed.
M&L for cleaning of manholes of various depth as follows including taking off manholes covers and re-fixing the same after cleaning dewatering and dislodging manually or mechanically removing the waste materials and sludge to a distance n.exc 50m and depositing where directed at site in borrow pits. (The rates included labour for earth work/excavation and removal of surplus soil to a distance not exceeding 50 metres:-
Manholes not exceeding 1.5m deep and of any size(length and width)
Manholes exceeding 1.5m deep and of any size(length and width)
M&L for cleaning of septic tanks by disludging inlet chambers, removing the waste materials by manually or mechanically (contaminated water and sludge/solid waste) and sludge to a distance to near by suitable distance as directed and depositing in the borrow pits as directed at site (During the cleaning measurement of Qty of contaminated water and solid waste/sludge in the percentages of 60% and 40 % respectively and paid separately in indl item) (The rates included labour for earth work/excavation and removal of surplus soil from pits to a distance n.exc 50 metres)
25 users
25 to 75 users
75 to 150 users
150 users and above
M&L for cleaning of drain pipes of SGSW/RCC of any dia (internal bore) including manholes channels by rodding manually or mechanically from manhole to manhole for cleaning eye and well flushing with water after cleaning complete all as specified and directed. Note: The rate also include followings (i) for taking off manhole cover and re-fixing the same after cleaning/removing the waste materials and sludge to a distance near by suitable distance and depositing in the borrow pits . (ii) for earth work/excavation and removal of surplus spoil for borrow pits)
Cleaning of blockage of Indian or European type water closet including blockage of Nahani trap or floor trap or gully trap of any size type upto the Ist manhole (blockage of any type took place at IWC or EWC, blockages of kitchen trap, bathroom, wash hand basin trap due to stuck of any substance or material due to any other reasons to the entire satisfaction of users/ Occupants manually or with using pumping device or any other suitable method or mechanically and getting the signature of the users on complaint slip for Zone 'A' area at BB Cantt Notes:- (i) . Contractor shall deploy four numbers of Safaiwala's to carryout day to day complaints (incl Sunday/holidays) of blockage etc and complaint slip shall be collected from the Complaint cell of AGE B/R-I. (Time of 04 x Safaiwala-0900hrs to 1700hrs).
BOQ item No 36.00 Contd.... (ii). Contractor has to make sure that the blockage complaints so received shall be completed within the 24 hours from the time of receipt and for any delay in completion of the particular complaint a penalty of rupees One hundread fifty (Rs 150/-) shall be recovered from the dues of contractor for delay in completion of complaint per day per complaint. (iii) Contractor has to make sure that upon requirement by the sub-division, the contractor has to depute the same four or more Safaiwala's for cleaning of MES Honey sucker after use of the equipment at GE 864 MT area. (iv).The payment shall be made to employees/safaiwala on or before 7th day of every calender Month. Payment to the employee shall be done by crossed ECs/NEFT through Aadhar linked bank account only and shall not be less than minium fare wages as per minimum Wages Act. (v). Contractor has to submit proof of payment and proof of EPF subscrption made by him alonghwith RAR/Final Bill. (vi). Contractor shall quote the rate considering employees monthly leave,relever etc as per labour law and nothing extra will paid on this account.
BOQ item No 36.00 Contd.... (vii).The rate quoted shall be inclusive of suitable reliever of manpower engaged by contractor. (viii) Cost of attendance register, printed work diary ,material register/security or entry passes and any other stationary reqd is to be born by the contractor and the rates quoted for the above are included in the quoted rates and no extra cost shall be claimed shall be entertained on this account. (ix) Penalty :- In case of absence of Safaiwalla the penalty shall be imposed @ Rs 800.00 per person per day and the same shall be recovered from contractor's dues. (x) Being defence installation, the contractor shall ensure that antecedents of the personnel deployed are verified through concerned Police authorities before their deployment. The character and antecedent verification report of each employee deployed by the contractor should be submitted. (xi) Contractor shall submit all documents before receipt of work order (Aadhar Card, Police verification and Bank Pass book Aadhar linked copy) of each worker intend to deploy on work.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 CM thickness (below or above ground level) complete all as specified and as directed
M&L 75 mm thick PCC 1:4:8 type D2-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and as directed
M&L prepolished chequered cement concrete tiles 25cmx25cm and 22 mm made using vibratory mechanical system having glazed top layer with mixture of white cement and pigment, set jointed and pointed in neat cement slurry in floors and 15 mm thick screed bed in CM 1:6 complete all as specified and as directed
M&L for machine pressed precast concrete inclocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade, including packing edges of tiles with grey cement and no pigment complete all as specified and as directed
M & L for sand filling under floors or in foundations including watering and consolidation.
M&L for Providing precast cement concrete louvres and jallies, 25mm thick (mea sured solid), in?cluding all mould- ings but excluding frame (Pre cast frame shall be measur?ed separately and paid for under item 04032) set in Cement mortar 1:4 type 1:2:4 B0 (12.5 mm graded aggregate) complete all as specified & directed.
Excavation in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth in layers n exc 25cm ,watering and removing surplus soil to a distance n. exc 50m and making good surface all as specified
S&F MS Angle iron as in posts struts for fencing posts etc confirming to Fe-310-0 complete all as specified.
S&F galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails staining bolts including, securing or tying at crossings with and provn of galvinised mild steel wire, staples or steel pins etc all as specified.
S & F Chain link MS gavinised fencing any size and type ( Wt 2 Kg/ sqm apprx) as specified and directed
S&F MS flat iron 40x6 to secure chain link fencing all as specified and directed.
Mild steel screw bolts (machine made) square head at one end screws on other for washer and nut n exc. 5cm long with dia of neck exc 12mm, complete all as specified and as directed
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide chrome primer, complete all as specified and as directed .
S & F Mild steel 12mm screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 10cm long.
M/S DFA Enterprises
ZAHOOR ENGINEERING WORKS
M/S MOHAMAD YOUSUF AKHOON AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .