Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC C O M KHARKARANG LUMJINGSUK BLOCK A MADANRTING SHILLONG 793021 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793021 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹27.7 L+₹2.9 L (11.5%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹31.4 L+₹6.6 L (26.7%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹36.9 L+₹12.1 L (48.9%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L4 | Rejected-Finance Being L4 |
| Sl No | Description | Qty | Unit | M/S BISWA CONSTRUCTION L3 | M/s M.L Consortium L4 | Bhuiya Construction L1 | MAHINDER ELECTRICALS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of existing roof padding including roof treatment complete carefully by cutting, chiselling etc cleaning the surfaces by scrapping, booming brushing etc and removing the rubbish from site to a distance exc 50m and n.exc 100m all as directed by the Engineer-in-Charge and M&L for applying roof treatment as under :-
(i) Providing 10mm thick (average) rendering in cement mortar 1:3 mixed with Liquid Water Proofing Compound as per manufacture's instruction (to be measured and paid including this item) for levelling to a true surface and to receive new roof treatment complete.
(ii) Providing coat of bitumen primer @ 0.40 Kg/Sqm complete .
(iii) Providing coat of hot blown bitumen of grade 85/25 @ 1.2 Kg/Sqm over primer surfaces alongwith aluminium paint @ 0.11 Kg/Sqm over the APP.
(iv) Providing a layer of APP based polymeric membrance of approved manufacturer, 3mm thick reinforced with polyester non wooven fabrix (weighing not less than 150 gm/ Sqm) laid by torch application method, side overlaps shall be minimum 75mm and end laps shall be minimum 100mm and sealing all overlaps and joints as manufacturer's insructions and provided upto a height o 60cm in the parapets and inserted inside the parapets by cutting a groove and finished by membrane flashing complete all as directed. | 1,090 | Square Meter | 1,500 ₹16,35,000 | 1,100 ₹11,99,000 | 650 ₹7,08,500 Lowest | 650 ₹7,08,500 Lowest |
| 2.00 | Supply and fix in repairs Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified. | 5,720 | Kilogram | 150 ₹8,58,000 | 165 ₹9,43,800 | 135 ₹7,72,200 Lowest | 190 ₹10,86,800 |
| 3.00 | Material and labour for prepration new or previously untreated steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. | 120 | Square Meter | 100 ₹12,000 | 220 ₹26,400 | 70 ₹8,400 Lowest | 70 ₹8,400 Lowest |
| 4.00 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 20 mm dia | 1,650 | Running Meter | 10 ₹16,500 Lowest | 25 ₹41,250 | 30 ₹49,500 | 19 ₹31,350 |
| 5.00 | Supply and fix 20 mm outer dia 3 layer PPR polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified.
Note: Necessary connection of PPR distribution branch with PPR main of 16-40 mm outer dia sizes by providing and fixing tee, bend, junction, reducer including cutting and making fusion joint etc are included in the quoted rate. | 1,650 | Running Meter | 100 ₹1,65,000 Lowest | 550 ₹9,07,500 | 180 ₹2,97,000 | 245 ₹4,04,250 |
| 6.00 | Supply and fix as in repairs 20 mm outer dia PPR Gate valves (brass insert) screwed both ends for PPR pipes and fixed to PPR pipes complete all as specified. | 91 | Each | 1,000 ₹91,000 | 700 ₹63,700 Lowest | 2,800 ₹2,54,800 | 1,444 ₹1,31,404 |
| 7.00 | Supply and fix as in repairs Rotational moulded polyethylene water storage overhead tanks (cylindrical vertical with closed top) multi layered 1000 ltr capacity hoisted and fixed in position including 20 mm dia Ball valves (Minimum weight of valve 210 gms) high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe complete all as specified. | 32 | Each | 9,000 ₹2,88,000 Lowest | 12,000 ₹3,84,000 | 10,000 ₹3,20,000 | 9,999 ₹3,19,968 |
| 8.00 | Supply and fix as in repairs Rotational moulded polyethylene water storage overhead tanks (cylindrical vertical with closed top) multi layered 500 ltr capacity hoisted and fixed in position including 20 mm dia Ball valves (Minimum weight of valve 210 gms) high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe complete all as specified. | 12 | Each | 4,500 ₹54,000 Lowest | 8,000 ₹96,000 | 5,000 ₹60,000 | 4,999 ₹59,988 |
| 9.00 | Disconnecting existing tanks of Capacity exceeding 250 ltr but not exceeding 500 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning repairing, etc.as directed by Engineer-In-Charge. | 12 | Each | 500 ₹6,000 | 600 ₹7,200 | 200 ₹2,400 Lowest | 250 ₹3,000 |
| 10.00 | Disconnecting existing tanks of Capacity exceeding 500 ltr but not exceeding 1000 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning repairing, etc.as directed by Engineer-In-Charge. | 34 | Each | 500 ₹17,000 | 700 ₹23,800 | 200 ₹6,800 Lowest | 350 ₹11,900 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
12 Dec 2025, 6:00 pmClosed
GE I AF SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
REPLACEMENT OF OVERHEAD TANK AND EXISTING GI PIPES TO PPR AT CERTAIN SMQS AT AF STATION LAITKOR PEAK UNDER GE (I) (AF) SHILLONG
2025_MES_740855_1
8075/25/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE I AF SHILLONG
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE I AF SHILLONG
₹87,000
Yes
12 Jan 2026
21 Nov 2025
15 Dec 2025
21 Nov 2025
12 Dec 2025
5 Dec 2025
Amount
Demolition of existing roof padding including roof treatment complete carefully by cutting, chiselling etc cleaning the surfaces by scrapping, booming brushing etc and removing the rubbish from site to a distance exc 50m and n.exc 100m all as directed by the Engineer-in-Charge and M&L for applying roof treatment as under :- (i) Providing 10mm thick (average) rendering in cement mortar 1:3 mixed with Liquid Water Proofing Compound as per manufacture's instruction (to be measured and paid including this item) for levelling to a true surface and to receive new roof treatment complete. (ii) Providing coat of bitumen primer @ 0.40 Kg/Sqm complete . (iii) Providing coat of hot blown bitumen of grade 85/25 @ 1.2 Kg/Sqm over primer surfaces alongwith aluminium paint @ 0.11 Kg/Sqm over the APP. (iv) Providing a layer of APP based polymeric membrance of approved manufacturer, 3mm thick reinforced with polyester non wooven fabrix (weighing not less than 150 gm/ Sqm) laid by torch application method, side overlaps shall be minimum 75mm and end laps shall be minimum 100mm and sealing all overlaps and joints as manufacturer's insructions and provided upto a height o 60cm in the parapets and inserted inside the parapets by cutting a groove and finished by membrane flashing complete all as directed.
Supply and fix in repairs Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified.
Material and labour for prepration new or previously untreated steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 20 mm dia
Supply and fix 20 mm outer dia 3 layer PPR polypropylene random copolymer concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PPR plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified. Note: Necessary connection of PPR distribution branch with PPR main of 16-40 mm outer dia sizes by providing and fixing tee, bend, junction, reducer including cutting and making fusion joint etc are included in the quoted rate.
Supply and fix as in repairs 20 mm outer dia PPR Gate valves (brass insert) screwed both ends for PPR pipes and fixed to PPR pipes complete all as specified.
Supply and fix as in repairs Rotational moulded polyethylene water storage overhead tanks (cylindrical vertical with closed top) multi layered 1000 ltr capacity hoisted and fixed in position including 20 mm dia Ball valves (Minimum weight of valve 210 gms) high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe complete all as specified.
Supply and fix as in repairs Rotational moulded polyethylene water storage overhead tanks (cylindrical vertical with closed top) multi layered 500 ltr capacity hoisted and fixed in position including 20 mm dia Ball valves (Minimum weight of valve 210 gms) high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe complete all as specified.
Disconnecting existing tanks of Capacity exceeding 250 ltr but not exceeding 500 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning repairing, etc.as directed by Engineer-In-Charge.
Disconnecting existing tanks of Capacity exceeding 500 ltr but not exceeding 1000 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning repairing, etc.as directed by Engineer-In-Charge.
MAHINDER ELECTRICALS (BID ID -3495693)
M/S BISWA CONSTRUCTION (BID ID -3493987)
M/s M.L Consortium (BID ID -3496010)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_829584.xls
BOQ • 0.32 MB
Tender8075.pdf
Tender Documents • 1.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .