| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.8 LAccepted-AOC | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹58.7 L+₹3.8 L (7.00%)Rejected-Finance A 3 257 2ND FLOOR JANAKPURI ASALATPUR ROAD JANAKPURI WEST DELHI DELHI 110058 UDYAM DL 11 0007281 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹58.8 L+₹4.0 L (7.33%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹59.8 L+₹5.0 L (9.16%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹60.5 L+₹5.7 L (10.4%)Rejected-Finance HOUSE NO 413 MAGADH COLONY SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹52 L
EMD Value
₹1.0 L
Closing Date
19 May 2020, 6:00 pmClosed
CWE Ranchi
HQ CWE RANCHI MES DIPATOLI CANTT PO RMCH RANCHI - 834009
PROVN OF ELECTRIC SUPPLY 500 KVA TRANSFORMER FOR MH NAMKUM AND LAY OUT OF HT CABLE AND INSTALLATION OF TRANSFORMER AT OFFRS MD ACCN AND OFFICERS MESS AT RANCHI
2020_MES_339311_1
80599/1289/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ranchi
Class C and above category b (ii)
7 documents required · 7 mandatory
₹1,000
Yes
GE RANCHI
₹1.0 L
Yes
13 Jun 2020
20 Apr 2020
23 May 2020
20 Apr 2020
19 May 2020
12 May 2020
Amount
Supply, installation, testing and commissioning Outdoor type, step down transformer of 500 KVA capacity,11 KV/433 Volts (at no load) AC 3 phase, 50 HZ, double copper wound type core, oil immersed, naturally cooled, oil natural Air Natural(ONAN) with external cooling tubes delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group Dyn-11 with neutral brought out on secondary side (LV) and having tappings at (-) 15% & +5% on HV side to changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after cotinuous full load run on an ambient temp of 40 degree celsius in oil as prevalling at site. The transformer shall be complete with the fittings and accessories comprising of items as mentioned in Annexure -1 of Schedule A - Note :- Annexure -1 of Schedule A is part of Scedule and uploaded with other tender documents. Transfomer shall be one of the following Make as approved by the GE : ABB/Siemens/Schneider .
M& L for earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less that 1.5 meters below normal ground level connected to galvanized iron strip 32 x 6 mm as earthing by means of bolts nuts and washers of galvanized iron including excavation and earth work and disposal of surplus soil including 40 mm GI tubing light grade and necessary fittings for protection of GI strip including laying of charcoal , dust and common slat , PCC 1:2: 4 type B 1 using 20 mm graded aggregate with earth pit with 40 X 40 X 6.0 mm MS angle iron frame RCC cover 40 mm thick (1:2: 4) type C1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75 mm C/C both way with plastering 15 mm thick CM ( 1: 6) internally and up to 150 mm below ground level externally . PGI funel with wire mesh ,20 mm dia medium grade GI pipe for watering complete all as shown on electrical plate No : 03 of SSR part - I 2009 and connected to earth test point including testing completed all specified and directed. Note:- galvanized iron strip 32 x 6 mm up to 7.5 meter connected to earth point shall be deemed to be included in unit rate.
Supply, installation, testing and commissioning of vacuum circuit breaker 400 A, Out going (VCBs) HT, 11KV three phase, 250 MVA AC supply, 26.3KA/3 Sec .Vacuum interrupters of the circuit breakers shall not be openly exposed design and shall be completely encapsulated in epoxy housing .The manufacturer of circuit breaker shall also be the manufacturer of the VI used in the breaker. The Circuit Breaker shall be suitable for E2, M2 & C2 (Single capacitor Bank) class duty. The offered circuit breaker should have valid type tests to support the above mentioned duty class. Tripping and/or release coils shall be continuous rated to ensure longer life. Integral spring charging handle to be provided in the CB with fittings and accessories comprising of items as mentioned in Annexure -2 of Schedule A - Note :- Annexure -2 of Schedule A is part of Scedule and uploaded with other tender documents. VCB shall be one of the following Make as approved by the GE : ABB/Siemens/Schneider / C&S .
Supply, installation, testing and commissioning of 11 KV Outdoor type extensible HT switch unit ( One way , with out metering panel ) floor mounted with internal copper bus bars, consisting of fixed type motorised Vacuum Circuit Breaker . All live parts, bus bars,VCB connections should be enclosed in one tank to avoid multiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The Unit shall be tested with internal arc of 21 kA for 1 sec with AFLR classification. The gas release and personnel safety with internal arc proofness shall not depend upon plinth design. The release of gases shall be from top of the unit so as that even if the person is operating the unit by opening the cover, top release will ensure safety. The release of gases in no case shall be from sides or bottom of the unit as the same is unsafe because of open plinth in sides in outdoor installations. The internal arc test shall be done for main tank and cable box both separately. Bidder shall provide necessary type test report confirming to IAC AFLR as per IEC 62271-200. .
The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of trouble shooting during breakdown.RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer confirms to IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external bus bar .The unit shall include the following with all necessary standard fitting required at site. Make : ABB/ C& S/ Seimens as approved by the GE
400 Amp VCB module for making & breaking of fault current alongwith Earth Switch of full making capacity-01 Nos. Motor operated 630/400 A Vacuum circuit breaker having spring stored mechanism. Three position disconnector/earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector/earthing switch “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 21KA/ 3 sec
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, two or more core, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of following size / cross sectional area , laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. including necessary Clamps, nuts , bolts, washers etc complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks and pipe shall be measured and paid separately under appropriate items
400 sqmm 3 ½ core
185 sqmm 3 ½ core
240 sqmm 3 ½ core
70 sqmm 3 ½ core
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. Below ground level connecting to GI Strip 25X4 mm size by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe light grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stoned aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (wight not less than 4 Kg/Sqm) and frame of angle iron 25x25 x3mm with lughs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test pont made out of phosphorous bronze with fixing arrangement, funnel, wiremesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. NOTE:- Galvanized iron strip 25 x 4 mm up to 7.5 meter connected to earth point shall be deemed to be included in unit rate. .
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Supply installation, commissioning and testing of LT panel board, Outdoor type, floor mounted, weather vermin proof factory made, CPRI approved, fabricated out of 3mm thick mild steel CRCA sheet mounted, on frame of mild steel angle iron 50 mm x 50 mm x 6 mm, 30 cms above the ground level duly supported with mild steel angle iron 65 mm x 65 mm x 6 mm thick in PCC foundation (1:2:4), type B-I, using 20 mm graded crushed stone aggregate, LT panel shall be totally enclosed with front double door and rear opening with IP-67 protection as per IS/8623 duly powder coated for 433 volts, 3 phase, 4 wire having TPN copper bus bars suitable for 1200 Amps load duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs/gland complete al as specified and directed by Engr-in-Charge and comprising of items as mentioned in Annexure -3 of Schedule A - Note :- Annexure -3 of Schedule A is part of Scedule and uploaded with other tender documents.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment.
Supplying and fixing light grade Galvanised mild steel water tubing, 80mm nominal bore, complete with all fittings and laid in trenches under roads/ drains,fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed.
Supplying, laying or fixing, jointing and testing 11 KV (E) system , Crossed linked polyethylene ( XLPE) insulated, screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables( heavy duty) ISI-7098 Mark, with aluminium conductor multi stranded of following size , laid in trenches/ laid under floor or fixed naked with walls / on poles etc. complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks and pipe shall be measured and paid separately under appropriate items
95 sqmm 3 core
70 sqmm 3 core
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type End joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for heat shrinkable type straight thorugh joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm complete all as specified and directed.
M&L Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers , welding, bending, cold or hot , drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zn Chrome and two coats of synthetic enamel paint all as specified.
Supply and fixing pin type porcelain, vitreous, white, brown or green insulators including galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nuts, 150 mm height 150 mm dia including section of straps of 38x5 mm size 20 mm dia of bolts, nuts & washers for 11000 volts grade. completed all as specified and directed.
Supply and fixing disc type insulator, porcelain, vitreous white, brown or green insulators for working pressure 11000 volt of 145 mm height 255 mm dia ball and socket type 'Two -in -series' asssembly for tension with tension clamp for conductors including bolts, nuts & washers completed all as specified and directed.
Supplying, stringing and stretching of Over head aluminium conductor steel reinforced (ACSR) of any size on HT/LT poles including binding and jointing the conductor with and including 14 SWG binding wire and coloured sleeved jumpers with jumper connections with PG clamps complete all as specified.
Supplying, transporting and erecting in position steel tubular swaged poles 410-SP-55 type, 11.00 M long complete with mild steel base plate, CI finial taper , bolts, nuts and washers etc. including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
Supplying, fixing, installing and commissioning and testing of 11 kV rated voltage, and 12 kV (max) system Voltage, 50 Hz frequency, 200 AMPs continuous current rating, fixed and moving contacts of Cu. alloy ( tinned) , single air break isolating switch gang operated, Triple pole, outdoor type, each pole consisting GI steel base, 3 Nos HT insulators (Total 09 nos) , non ferrous knife and spring loaded contacts, arcing horns of adequate section , horizontal GI pipe adequate length for phase separation, adequate length of GI pipe for operation from ground level and operating handle complete in 'Off' and 'ON' position, vertically mounting type, mechanically operated, mounted on and including insulators and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps complete with locking arrangemnets including pad locks with key complete ,providing two coats of Aluminium paint over one coat of primer on all steel surfaces complete all as specified.
S&F Danger notice plate 1.6 mm thick mild steel sheet, vitreous enamelled white , with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps , bolts and nuts of approved size, for HT , 25x20 cm size complete all as specified.
S&F Lightning arresters , HT, suitable for 11000 V expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete and connecting to conductors and earthing all as specified.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduits/ pipe or fixed to poles of any other indicated situation for loop earthing etc. of size 25x4 mm Galvanised mild steel strip complete all as specified.
Supplying, fixing, installing and commissioning and testing of 11 kV rated volatge, and 12 kV (max) system Voltage, 50 Hz frequency, 200 Amps continuous current rating, single phase Drop out fuse, outdoor type, each pole consisting GI steel base, 2 Nos HT insulators ,vertically mounting type, complete ,providing two coats of Aluminium paint over one coat of primer on all steel surfaces complete all as specified.
Supply, installation, testing and commissioning transformer suitable for 63 KVA step down, outdoor, plateform mounted double wound copper, 3 phase ,50 cycles (50 Hz) AC, oil immersed, natural air cooled with external cooling tubes having no load voltage ratio 11000/433 volts ( corresponding to principal tapping) winding delta connected on primary side (HV) and star connected on secondary side (LV side) in accordance with vector symbol Dyn-11 (vector group - 11) with neutral brought out on LV side for earthing and having tapping on HV side for constant out put so as to alter/ vary secondary voltage by + 5 % to + 10 % in steps of 2.5 % to be changed by means of manually operated "off load" taps changing gear. The limit of temperature rise after continous full load run as specified in IS-2026 shall be suitably adjusted to suit the maximum ambient temperature of 55 Degree Centigrade in HV/LV windings and 40 Degree centigrade in oil as prevalling at site. The transformer shall be complete with the fittings and accessories comprising of items as mentioned in Annexure -4 of Schedule A. Note :- Annexure -4 of Schedule A is part of Scedule and uploaded with other tender documents.
Supply , installation ,fabrication, testing and commissioning LT Panel box cubical , Outdoor type, CPRI approved, floor mounted, factory made out of 40mm x 40mmx4mm angle iron frame and 3 mm inner CRCA steel sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including suitable rated copper bus bars sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of 150 amps rated copper bus bars for phase and half for neutral and insulated with insulators complete with the following accessories incl PCC Foundation and Coping all as specified and directed by the engineer in charge and comprising of items as mentioned in Annexure -5 of Schedule A - Note :- Annexure -5 of Schedule A is part of Scedule and uploaded with other tender documents.
Capital Construction Company
RASAM ENGINEERING COMPANY
S.G.ENGINEERING COMPANY
M/S CHAUHAN CONSTRUCTION
SOOD ASSOCIATES PVT LTD
RISING ELECTRICALS
SANJOLI CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .