Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | ₹13.2 L | L1 | Accepted-AOC L1 Bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
19 Dec 2023, 3:00 pmClosed
Dr. Pallav Baruah
Bongora, Guwahati 781015, India
Supply of Outdoor Electrical panels for LT Power Supply Distribution at Indian Institute of Information Technology Guwahati
2023_IIITG_783794_1
IIITG/SnP/247/2023/154
Open Tender
Electrical Goods/Equipment
Item Rate
30 days
Bongora, Guwahati 781015, India
Technical bid qualification
2 documents required · 2 mandatory
₹0
₹25,000
Yes
23 Jan 2024
4 Dec 2023
20 Dec 2023
4 Dec 2023
19 Dec 2023
5 Dec 2023
Amount
Design, manufacture and supply of cubicle type, double door panel fabricated out of 2mm thick CRCA sheet steel, floor mounted totally enclosed switch board suitable for use of 415 volts, 3 phase, 50HZ AC supply system and to withstand a short circuit level of 50kA, having front and back side operation facilities. complete with aluminium bus-bar and all accessories including supply and fixing of following incoming and outgoing switchgears. and shall be dust and rain proof IP65 standard suitable for OUT DOOR installation on pedestal with the following facilities a) 3 nos. incoming breaker ON / OFF / TRIP indication lamp with SP MCB b) Fire and corrosion resistant coating applied in two coats with necessary primer The sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. c) Fire retardant DMC / SMC fittings for opening around bus-bars near the sectional barrier. d) Facilities for direct termination with 400 sqmm 3&1/2C armoured aluminium U/G cable - 2 nos for incoming and 2 nos. for outgoing feeders in LILO system.(Separate Aluminium bus bars are required to provide for cable termination facility ) . e) Shall have high mechanical strength f) Door interlocking facility. g) Shall have fire barrier. The panel shall be made as per relevant SI / IEC 61439 and relevant test certificate shall be furnished. Extended rotary handles for MCCBs and other accessories, all in compartmentalised, cubical construction complete in all respects as per approved drawing and design including internal wiring, labels, ferrules, cable termination gland plates, earth terminals, painting etc. conforming to specification
OUTDOOR FEEDER PILLAR No. 4 (To be written on Door of the panel) Incoming: 3P 800 A 50 KA Ics= 100% Icu fixed version ACB with microprocessor based, . electronic release having Current Adjustable Facility with built in S/C, O/C and E/F Protection, and spreader terminal - 1 Nos. (Make ; Legrend DMX SP 2500 or equivalent L&T or Semans as approved). 1000 A TPN AL. bus bar with coloured heat shrinkable PVC sleeve-1 Set Outgoings: 320 A 3P MCCB, 36 KA (with thermal magnetic protection e for S/C,O/C,& E/F ) - 2 Nos. 200 A 3P MCCB, 25 KA - 2 Nos. (with thermal magnetic protection for S/C,O/C,& E/F ) – 2 Nos. Instruments: Digital Voltmeter (0-500 V) Indication lamp RYB with MCB protection etc. as req. 3 nos. incoming breaker ON / OFF / TRIP indication lamp with SP MCB Bus bar connection facility shall be provided to connect 400 sqmm 3&1/2C armoured aluminium U/G cable - 3 nos for incoming and 2 nos. for outgoing feeders in LILO system.
OUTDOOR FEEDER PILLAR No. 5 (To be written on the door of the panel) Incoming: 3P 800 A 50 KA Ics= 100% Icu fixed version ACB with microprocessor based, . electronic release having Current Adjustable Facility with built in S/C, O/C and E/F Protection, and spreader terminal - 1 Nos. (Make ; Legrend DMX SP 2500 or equivalent L&T or Semans as approved). 1000 A TPN AL. bus bar with coloured heat shrinkable PVC sleeve-1 Set Outgoings: 320 A 3P MCCB, 36 KA - 1 Nos. (with thermal magnetic protection for S/C,O/C,& E/F ) 200 A 3P MCCB, 25KA - 2 Nos. (with thermal magnetic protection for S/C,O/C,& E/F ) – 40 A 3P MCCB, 16 KA - 3 Nos. (with thermal magnetic protection for S/C,O/C,& E/F ) 40 A 4P MCB, 16 KA - 1 Nos. – 40A DP MCB, 16 KA - 3 Nos.- Instruments: Digital Volt meter ( 0-500 V) Indication lamp RYB with MCB protection etc. as req. 3 nos. incoming breaker ON / OFF / TRIP indication lamp with SP MCB Bus bar connection facility shall be provided to connect 400 sqmm 3&1/2C armoured aluminium U/G cable - 2 nos for incoming and 2 nos. for outgoing feeders in LILO system.
OUTDOOR FEEDER PILLAR No.6 (To be written on the Door of the panel) Incoming: 3P 800 A 50 KA Ics= 100% Icu fixed version ACB with microprocessor based, . electronic release having Current Adjustable Facility with built in S/C, O/C and E/F Protection, and spreader terminal - 1 Nos. (Make ; Legrend DMX SP 2500 or equivalent L&T or Semans as approved). 1000 A TPN AL. bus bar with coloured heat shrinkable PVC sleeve-1 Set Outgoings: 200A 3P MCCB, 36 KA - 1 Nos. (with thermal magnetic protection for S/C,O/C,& E/F ) -Indoor stadium ) 63 A 4P MCCB, 25 KA - 1 Nos. (with thermal magnetic protection for S/C,O/C,& E/F ) - 1 40 A 3P MCCB, 25 KA - 7 Nos. (with thermal magnetic protection for S/C,O/C,& E/F ) - 4 nos.. 40 A 4P MCB, 16 KA - 1 Nos. – 40A DP MCB, 16 KA - 3 Nos.- Instruments: Digital Volt meter ( 0-500 V) Indication lamp RYB with MCB protection etc. as req. 3 nos. incoming breaker ON / OFF / TRIP indication lamp with SP MCB Bus bar connection facility shall be provided to connect 400 sqmm 3&1/2C armoured aluminium U/G cable - 2 nos for incoming and 2 nos. for outgoing feeders in LILO system.
OUTDOOR FEEDER PILLAR No. 7 (To be written on door of the panel) Incoming: 3P 800 A 50 KA Ics= 100% Icu fixed version ACB with microprocessor based, . electronic release having Current Adjustable Facility with built in S/C, O/C and E/F Protection, and spreader terminal - 1 Nos. (Make ; Legrend DMX SP 2500 or equivalent L&T or Semans as approved). 1000 A TPN AL. bus bar with coloured heat shrinkable PVC sleeve-1 Set Outgoings: 320A 3P MCCB, 36 KA -1 Nos. (with thermal magnetic protection for S/C,O/C,& E/F ) – 200 A 3P MCCB, 36 KA - 3 Nos. (with thermal magnetic protection for S/C,O/C,& E/F ) –- 2 40 A 4P MCB, 16 KA - 1 Nos. - Spare Instruments: Digital Volt meter ( 0-500 V) Indication lamp RYB with MCB protection etc. as req. 3 nos. incoming breaker ON / OFF / TRIP indication lamp with SP MCB Bus bar connection facility shall be provided to connect 400 sqmm 3&1/2C armoured aluminium U/G cable - 2 nos for incomming and 2 nos. for outgoing feeders in LILO system.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .