Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹37.3 L+₹1.9 L (5.26%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹37.6 L+₹2.1 L (6.05%)Rejected-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹38.8 L+₹3.4 L (9.58%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹38.9 L+₹3.5 L (9.91%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
16 Oct 2023, 6:00 pmClosed
SHRI PRAVEEN KUMAR, IDSE
GE KHADAKWASLA, NDA KHADAKWASLA, PUNE-23
REPAIR MAINT OF STREET LIGHTS / SECURITY LIGHTS / EXTERNAL LIGHTS AT NDA KHADAKWASLA
2023_MES_619255_1
8763/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE KHADAKWASLA
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE KHADAKWASLA
₹96,000
Yes
6 Nov 2023
16 Sept 2023
21 Oct 2023
16 Sept 2023
16 Oct 2023
2 Oct 2023
16 Sept 2023 - 1 Oct 2023
Amount
Repair / maintenance of street / security lights any type, flood lights, post top lanterns or any other external lights in its position fixed on pole /building structure or by taking down to ground, if required, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like electronic driver,surge protection device (SPD) connection wires/ cable, MCB etc including refixing the fitting to its original position (if taken down), including repair / maint of street light control timer & junction box all as directed by Engr-in-charge. Note: (i) The rate against the above mentioned item is deemed for cost of labour and allied expenses only. (ii) Cost of spares electronic driver,surge protection device (SPD), connection wire, MCB, timer contactor spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defective street light fittings and will submit the completion report on the same day before 1730hrs to the JE E/M. (iv) The contractor has to rectify the defects / repair and make the street light functional within 24 hours from the time the list of defective street lights is handed over to him / his rep by the concerned JE E/M. In case the street light is not made functional for whatsoever reason within the specified time limit, an amount of Rs 150/- per such defective street light per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall carry out repair / maint work simultaneously for different zones / pocket / areas like :- (a) Training & administrative bldgs area including main road from Trishakti gate to Bombay stadium (b) Offrs residential area D1, D2, D3, E3 including main road from Bombay stadium to peacock bay, road to LVGH & Kondhana (c) JCOs/OR and followers residential area by engaging seprate team of electricians / technicians in order to ensure promptly & timely rectification of defects. (v) Vehicle mounted hydraulic ladder shall be provided on contractor's request which will be measured separately under Schedule 'C'. (vi) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vii) The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipments and clothings to his men and department shall not be responsible for any kind of mishap / accident / injury to his men. (viii The contractor shall maintain sufficient stock of spares / material required for repair / maint of street lights with the concerned JE E/M against the supply only items here-in-below.
Supply only following street light spares of branded make as mentioned in the list of make enclosed with Particular specifications for replacement:- (i) Electronic driver suitable for 90watts LED security light fittings Make should be as per the Existing manufacturer.
(ii) Electronic driver for 40/ 45 / 48 / 50/60 watts LED road way/Flood light/post top Make should be as per the Existing manufacturer complete all as specified and directed.
(iii) Electronic driver for 300 watts flood lights Make should be as per the Existing manufacturer complete all as specified and directed.
(iv) Electronic driver for 200 watts flood lights Make should be as per the Existing manufacturer complete all as specified and directed.
(v) Electronic driver for 150 watts flood lights Make should be as per the Existing manufacturer complete all as specified and directed.
(vi) Electronic driver for 100 watts flood lights Make should be as per the Existing manufacturer complete all as specified and directed.
(vii) Surge protection device(SPD) of capacity 10KA compatible with industrail & outdooor LED fixtures Make should be as per the Existing manufacturer complete all as specified and directed.
(viii) MCB SP 230 volts B curve 6 amps complete all as specified and directed.
(ix) MCB DP 230 volts C curve 6 amps complete all as specified and directed.
(x) MCB TPN 230 volts C curve 63 amps complete all as specified and directed.
(xi) MCB TPN 230 volts C curve 40 amps complete all as specified and directed.
(xii) Digital time switch, DIN type daily / weekly with 25 ON/OFF programmes , 16 amps 250 volts AC complete all as specified and directed.
(xiii) Power contactor 16/18 amps 3 pole complete all as specified and directed.
(xiv) Power contactor 40 amps 3 pole complete all as specified and directed.
(xv) PVC insulated Copper conductor FRLS grade two core cable 1.5 sqmm, ISI marked complete all as specified and directed.
(xvi) PVC insulated aluminium conductor two core round cable 1.5 sqmm, ISI marked complete all as specified and directed.
(xvii) MCCB 63 Amps 4 pole 415 V complete all as specified and directed.
(xviii) Relay of capacity 110V-240V AC Capacity complete all as specified and directed. Make : L&T catpart No: CS94039 or equivalent in makes as mentioned at makes list in PS
Restreaching tightening and fixing in position, the existing OH ACSR conductor LT Line 3 phase with neutral and earth wire 440 V 5/6 wire by loosing and taking down existing binding wire from the insulator of any size of ACSR conductor and bring it to required sag incl new binding wire and tightening of cross arm on each pole and required trimming of tree branches Note: 1.one Span length (any Nos of wire of conductor )shall be measured as running meter unit 2.Unit rate quoted by the contractor shall be deemed to incl for cutting and trimming branches of the trees coming in contact with ACSR conductor and separators complete all as specified and directed.
M&L for straight through joint (epoxy) for PVC insulated and sheathed aluminium conductor under ground cable incl freud , thimbles, nut & bolts, washers etc and testing after jointing complete all as specified and directed (a) 16 sqmm to 35 sqmm 3.5 core
Supply & Laying, jointing & testing of UG LT cables XLPE insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ ducts/ along poles/through pipe under road etc with new aluminium lugs of cable size complete all as specified and directed.
Ditto all as per item No 22 above but size 16 sqmm 4 core
Ditto all as per item No 22 above but size 10sqmm 4 core
Ditto all as per item No 22 above but size 6 sqmm 4 core
Ditto all as per item No 22 above but size 4 sqmm 3 core
Excavation in trenches in hard/dense soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed.
Returning, filiing in incl spreading, leveling watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested complete all as specified and directed.
Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and laying 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e coupler, Tee, elbow clamp for cable protection complete all as specified and directed.
Supply and fix in replacement of sintex box thermo plast (weather proof) IP 66, on street light poles made out of thermoplastic of size 300mm x 200 mm x 105 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB DP 06 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable complete all as specified and directed. Make Sintex Cat pat No GSJB-3020 or equivalent in makes as mentioned at makes list in PS
Supply and fix in replacement of sintex box thermo plast (weather proof) IP 66, on flood light poles made out of thermoplastic of size 140mm x 140 mm x 95 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB SP 6 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and wahers and suitable size of double compression cable glands for incomming, outgoing of cable complete all as specified and directed. Make Sintex Cat pat No GSJB-1414 or equivalent in makes as mentioned at makes list in PS
S&F distribution box 2 Module 230V, 5 HZ, IP-65 & IK-09 Class-II, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos, coppper fork type 100 A busbars as short link including end caps, qty-1 nos, MCB SPN 32 Amp 230V, 50 HZ, complete all as specified and directed. Make: Legrand Catpart No 601932 or equivalent in makes as mentioned at makes list in PS
S&F in replacement MCB DB 02 way SPN (single door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, surface mounting complete including MCB SPN 06 Amp 230V, 50 HZ, complete all as specified and directed.
S&F in repair of GI pipe bracket of 40 mm dia 1.2mtr long bend to shape for street light fitting made out of 40 mm dia GI light grade pipe fixed on pole using new FI clamp including necessary new nut, bolt and washer complete all as specified and directed.
Supply & fix GI tubing light grade 40 mm dia isi marked appx 1 mtr to 1.5 mtr long with Flat Iron Base for mounting of Flood light with all fittings incl nut,bolt,washers suitable size complete all as specified and directed.
S& F GI tubing light grade 50 mm dia ISI marked with all fittings laid in trenches and fixed pole by flat iron clamps, nut, bolt, washers suitable size complete all as specified and directed.
Labour for trimming / pruning tree branches overhanging or interfering or obstructing electrical pole or street lights complete all as directed in such a way that the clearance between Street light pole and tree branches should not be less than 1.5 mtrs around the Pole/Fitting complete all as specified and directed.
Material and labour for Tarmac bituminised road cutting by using suitable hydraulic road cutter for a width not exceeding 300 mm and depth 600 mm for laying of 80 MM medium grade GI pipe incl refilling and making good with Tarmac/ PCC duly matching with the existing surface complete all as specified and directed. Note:1. Quoted rate shall be incl of 80 MM Gi pipe medium grade 2. Quoted rate shall deemed to incl the cost of making good the disturbed surface.
Supply and fixing of 2 inch width retro reflective tape fixed to Street light Poles with red colour including removing existing damaged reflected strips from pole complete all as specified and directed.
Supply and fixing of 2 inch width retro reflective tape fixed to Street light Poles with yellow colour including removing existing damaged reflected strips from pole complete all as specified and directed.
Supply and fixing of 2 inch width retro reflective tape fixed to Street light Poles with white colour including removing existing damaged reflected strips from pole complete all as specified and directed.
Suply & fixing in replacement of 30 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 complete all as specified and directed. Make:LUKER-LFLSL30/BAJAJ-GLEAM F 33L WH SY PC SD V2/HAVELLS-JETAADORNFLS30WLED757SSYMTOTG equivalent in makes as mentioned at makes list in PS
Suply & fixing in replacement of 50 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 complete all as specified and directed. Make:LUKER-LFLSL50 or BAJAJ-GLEAM F 55L WH SY PC SD V2 or HAVELLS-JETAADORNFLS50WLED757SSYMTOTG or equivalent in makes as mentioned at makes list in PS
S & F in replacement of 100 watts flood light Warm white in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as required at the site complete all as specified and directed. Make:LUKER-LFLSL100 or HAVELLS-JETAADORNFLS100WLED757SSYMTOTG or BAJAJ-PRAZE F120L WH NB-A5 TG SD or equivalent in makes as mentioned at makes list in PS
S & F in replacement of 150 watts flood light Warm white /White in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as required at the site complete all as specified and directed. Make:LUKER-LFLSL150 or HAVELLS-JETAADORNFLS150WLED757SSYMTOTG or BAJAJ-PRAZE F180L WH NB-A5 TG SD or equivalent in makes as mentioned at makes list in PS
S & F in replacement of 200 watts flood light Warm white in colour, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as required at the site complete all as specified and directed. Make:LUKER-LFLSL200 or HAVELLS-JETAADORNFLS200WLED757SSYMTOTG or BAJAJ-PRAZE F240L WH NB-A5 TG SD or equivalent in makes as mentioned at makes list in PS
S&F LED 120 watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl complete fixing to pole/wall with necessary nut, bolts and washers complete all as specified and directed. Make:LUKER-LST-120/HAVELLS-ENDURASUNBEAMSL120WLED / BAJAJ-ZELA P 144L WH PO TG SD equivalent in makes as mentioned at makes list in PS
S&F LED 90watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl complete fixing to pole/wall with necessary nut, bolts and washers complete all as specified and directed. Make:LUKER-LST-90 or HAVELLS-ENDURASUNBEAMSL90WLED or BAJAJ-ZELA P 108L WH PO TG SD or equivalent in makes as mentioned at makes list in PS
S&F LED 45 to 60 watt street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl complete fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed. Make:LUKER-LST-48 or HAVELLS-ENDURASUNBEAMSL45WLED or BAJAJ-ENXT P 54L WH CR PC SD or equivalent in makes as mentioned at makes list in PS
Supply and Fixing in replacement 15 Watt weatherproof LED post top lantern with aluminium housing, clear acrylic diffuser, aluminium pole-cap complete with all accessories complete all as specified and directed. Make:HAVELLS-CORALMINIPT15WLED830PSYMTOPC or BAJAJ-BGCTNP 20W LED WH or equivalent in makes as mentioned at makes list in PS
Supply and Fix in replacement integral 25 Watt LED post top lantern black/ copper dust painted cast aluminium spigot, spun aluminium canopy with clear acrylic cover and accessorieson on existing GI Pipe of diameter complete all as specified and directed. Make Bajaj (ARIAN) Cat No BGCTN 25W LED WW or equivalent in makes as mentioned at makes list in PS
Supply & fix in replacement 40 watt LED post top made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 65 protection complete all as specified and directed. Make: Surya Cat No SLEPT 40W -ETPP or equivalent in makes as mentioned at makes list in PS
M&L for scrapping down and removing of old deteriorated paint from steel tubular poles LT (07 to 08 Mtr) height above ground level , preparing surface for painting , applying two coats of aluminium paint upto full height of pole including MS clamps, GI bracket, fitting ets all as directed at site including making black and white strips of 30 cms each upto 1.5 m above PCC muffs with black and white paint and marking of pole No 2 m above PCC muff, letter should not be longer than 6 cm height with 16 cm dia circle around the marked NO complete all as specified and directed.
M&L for scrapping down and removing of old deteriorated paint from Post top lantern poles (RCC/GI) /(2 to 3 mtr) height above ground level , preparing surface for painting , applying two coats of black paint upto full height of pole including MS clamps, GI bracket, fitting ets all as directed at site complete all as specified and directed..
Supply and Fixing 1x18 watt WW (3000K) LED bollard Integral decorative LED bollard with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and provide PCC(1:2:4) type B1 for new bollard as per site requirement and fixing arrangements complete all as specified and directed. Note: Quoted rate shall includes provision of PCC for new bollard Make Luker Catpart No: LOBRD60 or equivalent in makes as mentioned at makes list in PS
Supply and Fixing 1x12 watt WW (3000K) LED bollard Integral decorative LED bollard with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and provide PCC(1:2:4) type B1 for new bollard as per site requirement and fixing arrangements complete all as specified and directed. Note: Quoted rate shall includes provision of PCC for new bollard Make Luker Catpart No: LODBR12 or equivalent in makes as mentioned at makes list in PS
Supply and Fixing 1x10 watt WW (3000K) LED gate light with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and provide PCC(1:2:4) type B1 for new gate light as per site requirement and fixing arrangements complete all as specified and directed. Note: Quoted rate shall includes provision of PCC for new gate light Make Luker Catpart No: LGLSMD or equivalent in makes as mentioned at makes list in PS
Supply and Fixing 1x18 watt WW (3000K) LED outdoor gate light with polycarbonate diffuser and IP 65 protection incl demolition of existing PCC and provide PCC(1:2:4) type B1 for new gate light as per site requirement and fixing arrangements complete all as specified and directed. Note: Quoted rate shall includes provision of PCC for new gate light Make Luker Catpart No: LGLRBGE-27 or equivalent in makes as mentioned at makes list in PS
Supply and fix 5 W LED Solar garden light of lithium ferrous 3.7v 5200mAH battery, automatic on/off using LED sensor IP 65 Protection aluminium body complete all as specified and directed. Make : Luker Catpart No. LBRSOL600 or equivalent in makes as mentioned at makes list in PS
S&F in replacement of HOT dip galvanised Octagonal pole 9 mtr height having across faces bottom side 155 mm top side 70 mm made out of 3 mm thick HT sheet steel plate along with base plate of size 260x260x16 mm thick and required nut ,bolts, sutable PCC foundation if reqd as per manufacture instructions complete all as specified and directed.
Supply, transport, errecting and fixing steel tubular swaged welded pole of over all height 8.5 m long complete type 410-SP-22 conforming to IS-2713 (Part I to III 1998 with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc including removal of existing damaged pole complete all as specified and directed. Note: (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. The quoted rates shall includes the following :- (ii) Pole upto 1.5 m top of coping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer. (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer (iv) Pole below ground shall be tarred by one coat (v) Poles shall be numbered
M&L PCC 1:3:6 type C-2 (using 40 mm size graded stone aggregate) Cement concrete as in foundations, filling and mass concrete complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20 mm size graded stone aggregate) as in coping of pole sand including formed work and demolition of existing coping complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm size graded stone aggregate) Cement concrete in foundations, filling and mass concrete complete all as specified and directed.
S&F in replacement of digital timer switch distribution board, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps 3 Pole MCB, power contactor and 230V digital time switch for controlling LED/SV etc street lights , including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35x35x4mm thick angle iron supports of not less than each 0.6 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 type C1 at suitable depth as per site requirement complete all as specified and directed.
S&F in replacement for PVC insulated aluminium conductor two core cable 2.5 sqmm ISI marked including PVC conduit pipes of dia not less than 19 mm complete all as specified and directed.
S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, 300mm X 40mm X 5mm (thickness) electrolytic grade of adequate rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with 4. RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. including incoming and outgoing cable connection, glands, thimbles All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 25mmx25mmx3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted on wall (at Sudan Dome)and suitable fixing arranement as per site requirement. The overall size of the Busbar panel shall be 350mmx200mmx400mm (LxBxH).including PCC 1:3:6 type C1 complete all as specified and directed.
S&F plexo box & adopter with PVC membrane of 3 Module IP-55 including 01 no of 15 Amps socket and 15 amp switch complete all as specified and directed. Make: Legrand Catpart No 680613 or equvaleint in L&T/Schinder
M & L for making hole on a street light pole top and bottom for entry of service wire of 1.5 sqmm disconnecting the existing service connection from junction box and fitting and reconnecting the same to junction box and fitting including testing complete all as specified and directed.
RAJKUMAR KISHANCHAND JASWANI
KESARI AND SONS
J B ELECTRICALS
R K ENTERPRISES
SOURABH ENGINEERS
CHAITANYA WINDWELL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .