Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 2ND 6 KEDIA HOUSE MA ROAD BYELANE 1 REHABARI GUWAHATI ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Disqualified |
Tender Value
Refer Docs
EMD Value
₹86,900
Closing Date
5 Mar 2024, 11:00 amClosed
SO-1 (Wks), HQ DGAR
HQ DGAR, Engr Branch, laitkor, Shillong-10
Special Repair of internal wiring of Separate Family accommodation at Jorhat
2024_ARMHA_796988_1
VIII. 11014/8036/Engr-2023/Spl R/RB/25 Sect
Open Tender
Civil Works
Works
180 days
Jorhat
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
DGAR
₹86,900
Yes
22 Mar 2024
22 Feb 2024
6 Mar 2024
22 Feb 2024
5 Mar 2024
22 Feb 2024
22 Feb 2024 - 5 Mar 2024
Amount
SCHUDULE 'A' PART I (SPECIAL REPAIR OF INTERNAL WIRING OF SEPARATE FAMILY ACCOMMODATION TYPE-II & TYPE-III (BUILDING NO. 211 TO 223) ACCOMMODATION AT HQ 25 SECTOR ASSAM RIFLES AT JORHAT)
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required
Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing of 20 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 5/6 Amps Switch.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 2 way 5/6 Amps Switch.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 3 pin 5/6 Amp Socket outlet.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required Bell push
Supplying and fixing metal box of 75 mm X75 mm X 60 mm deep (nominal size) n surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
Supplying and fixing metal box of 200 mm X150 mm X 60 mm deep (nominal size) n surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
Supplying and fixing metal box of 200 mm X 250 mm X 60 mm deep mm deep (nominal size) n surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel etc. as required enclosure,surface or in recess, with chained metal cover for the socket out on let and complete with connections, testing and commissioning
Supplying and fixing 2 way stepped type electronic fan regulator 230 volt AC on the existing switch box including connections as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ PVC angle holder including connection etc. as required.
Supplying and fixing 4 way (4 + 12), Single door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of triple pole & neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 8 way , Double door, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of Single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
CHEDULED 'A' PART -II (SCHEDULED OF CREDIT)
Less Old Retrieved Wire [(-) Rs. 58000]
Less Old Retrieved Metal Box [(-) Rs. 7135]
RS constructions
ADITI CONSTRUCTION CO
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .