Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-2₹3.5 L+₹94,409.96 (37.1%)Accepted-AOC AT DAKRA P O DAKRA DISTT RANCHI JHARKHAND PIN 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | L-2 | Accepted-AOC As per Recommendation of TC and Approval of Competent Authority | |
| 2 | L-1₹2.5 LRejected-Finance AT BACHRA P O BACHRA P S PIPARWAR BACHRA 829201 | BACHRA | CHATRA | JHARKHAND | 829201 | L-1 | Rejected-Finance As per Recommendation of TC and Approval of Competent Authority | |
| 3 | L-3₹3.9 L+₹1.4 L (53.6%)Rejected-Finance AT SUBHASH NAGAR BESIDE QTR NO CHB 22 P O RAY JHARKHAND PIN 829209 | RAY | RANCHI | JHARKHAND | 829209 | L-3 | Rejected-Finance As per Recommendation of TC and Approval of Competent Authority |
Tender Value
₹3.2 L
EMD Value
₹4,100
Closing Date
31 Oct 2022, 5:00 pmClosed
Staff Officer (EnM), M-S Area
Office Of The General Manager M-S Area, Bachra. 829201
Work of Fresh electrical wiring with service connection for ACs./ Lighting circuit and Providing / fixing of recessed mounting LED luminaries fittings with Proper control circuit at canteen building of Pratiksha guest house, under GM unit M-S Area.
2022_CCL_259862_1
GM(M-S)/SO(EnM)/e-NIT/22-23/39
Open Tender
Electrical and Maintenance Works
Item Rate
5 days
Office Of The General Manager M-S Area, Bachra.
Please Refer NIT
4 documents required · 4 mandatory
₹4,100
10 Sept 2023
19 Oct 2022
1 Nov 2022
20 Oct 2022
31 Oct 2022
20 Oct 2022
20 Oct 2022 - 28 Oct 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Group A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire COST FOR 50 METERS
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Group A COST FOR 1 POINT
Wiring for light/power plug with 2x4sqmm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1No. 4 sqmmFR PVC insulated copper conductor single core for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire COST FOR 50 METERS
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire COST FOR 50 METERS
Supply of 2+2 way, SPN single door, MCB distribution box.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole Details of cost for one each
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.4 x 6 sq. mm COST FOR 50 METRES
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 125 mm X 60 mm deep COST FOR EACH
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral Details of cost for one each
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A 30 KA 4Pole Details of cost for one each
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc.as required.63 A Details of cost for one each
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required .8 way (4 + 24), Double door Details of cost for one each
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and saltas required. Details of cost for one Set
EProviding and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Details of cost for 10 Metres
Supply of exhaust fan 300 mm high speed
Decorative ultra ceiling LED tube light fitting 25 W LED
Wall fan Swing 400 mm BLDC fan
Recessed mounting LED down lihgt luminiaries fitting 18 W with highly efficient acylic diffuser
Supply of 16 sq. mm 4 core aluminium armoured cable 1.1 KV Grade ISI Marked
erection / fixing charge 15 % on items number 19, 20, 21,22 ,23
Total impact of GST for the purpose of CTC
M/S MEHTA ELECTRONICS
ODYSSEY INTERNATIONAL
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_268735.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .