Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.1 LAccepted-AOC | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹24.2 L+₹69,496 (2.96%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹26.5 L+₹3.1 L (13.0%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest | |
| 4 | L-4₹26.8 L+₹3.3 L (14.2%)Rejected-Finance | L-4 | Rejected-Finance Being other than lowest | |
| 5 | L-5₹27.0 L+₹3.5 L (14.8%)Rejected-Finance | L-5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹79,300
Closing Date
12 Oct 2021, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-180003
CERTAIN SPECIAL REPAIR, LBW AND MINOR WORK OF E/M NATURE AT SUNJUWAN, DAMANA AND MIRAN SAHIB UNDER GE JAMMU
2021_MES_473546_1
GEJC-33/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹79,300
Yes
9 Dec 2021
7 Sept 2021
14 Oct 2021
7 Sept 2021
12 Oct 2021
21 Sept 2021
Amount
Taking down old UNSV copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
M&L in replacement for Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
M&L for point wiring for one light / fan / 5 Amps independent socket point / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / steel conduit 1.8mm wall thickness ISI marked terminated into CI / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling, PVC conduit shall be provided on surface with proper fixing clips complete all as specified and as directed by Engr-in-Charge. (d) Wiring should be done from existing DB board separately.
Description same as per Ser Item No 3.00 here-in-before but for multi 5 pin 5 amp socket outlet on same board complete all as specified and as directed.
Description same as per Ser Item No 3.00 here-in-before but for multi 3 pin socket outlet 5 amp socket on independent board complete all as specified and as directed.
Description same as per Ser Item No 3.00 here-in-before but for one light point controlled by two 2 way switches, with cable 1.5 Sqmm complete all as specified and as directed.
Description same as per Ser Item No 3.00 here-in-before but for one bell / buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 Sqmm size complete all as specified and as directed.
Description same as per Ser Item No 3.00 here-in-before but for multi 3 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistranded cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20 / 25 mm dia and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green colour complete all as specified and as directed by Engr-in-Charge complete with new CI / pressed steel sunken black with hylum top sheet cover complete all as specified and as directed.
S&F in replacement for socket outlet 5 Pin, 5A, flush type complete all as specified and as directed.
S&F in replacement for switch piano, flush type single pole one way 5 Amp, 240 Volts complete all as specified and as directed.
S&F in replacement for modular switch two way 6 amps, 1 module complete all as specified and as directed.
S&F in repair for bell push, flush type single pole, 5 Amps, 240 Volts complete all as specified and as directed.
S&F in repair ceiling rose, 3 phase / PVC / polycarbonate isolated body complete all as specified and as directed.
S&F in repair switch piano, flush button, single pole one way 15 Amp complete all as specified and as directed.
S&F in repair socket outlet 3, 5 pin and 15 Amp multipurpose shuttered type complete all as specified and as directed.
S&F in replacement calling bell ding dong / buzzer AC 230 Volts, single pole complete all as specified and as directed.
S&F in repair fan regulator stepped electronic type suitable for AC, 240 Volts complete all as specified and as directed.
M&L in replacement for Lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
M&L in replacement Self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
S&F in replacement LED light fittings 1 X 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and powerfactor >0.95, 100 Lumen / Watt, 6500K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts, 50 Hz complete all as specified and as directed.
S&F in replacement LED light fitting 1 X 9W / 1 X 10W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Taking down existing UNSV ceiling fan, repair / maint including replacement UNSV spare parts i.e. bearing, bush, PVC connector, PVC clamp, canopy, capacitor, including painting, rewinding of any make / type and size (1200 / 1400mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specifications, including replacement of all insulation materials, varnishing, heating, drying, assembling of stator / rotor, connection and testing complete all as specified and as directed.
Taking down existing UNSV Exhaust fan, repair / maint including replacement UNSV spare parts i.e. bearing, bush, PVC connector, PVC clamp, canopy, capacitor, including painting, rewinding of any make / type and size with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stator / rotor, connection and testing complete all as specified and as directed.
S&F in replacement of vertical distribution board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing 12 No's MCB's and should be IP-43 protected with copper busbars, neutral links, earthing bar complete all as specified and as directed including taking down old UNSV DB / MCB any type. Note: - (i) Rates includes MCCB four pole 125 Amp, 16 KA, 415 Volts with adjustable thermal settings. (ii) Rate includes MCB SP 40 Amps 12 No's 10 KA. (iii) TPN DB, MCB and MCCB should be of same make.
M&L for replacement distribution board sheet steel powder coated for MCB with copper busbar and neutral link earthing stud SPN 8 way 240 Volts double door complete all as specified and as directed by Engr-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement SPN 40 to 63 Amp 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning all as specified and as directed.
S&F in replacement 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection, testing and commissioning all as specified and as directed.
Taking down existing serviceable / unsv electric meter alongwith existing angle iron steel box from the wall and refixing electric meter in position after repair, replacement of MCB TPN box including replacement of PVC flexible conduit for cable protection complete with making the existing wall neat and clean including patch work, plaster, brick work and white wash as per site requirement complete all as specified and as directed.
S&F in repair for Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and making good bottom surface for laying / removing of cable complete all as specified and as directed in hard soil.
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 V grade cross sectional area 25 Sqmm 4 core in and including taking out old one complete all as specified and as directed.
M&L sand filling in cushioning bed of cable and consolidation complete all as specified and as directed.
Supply and laying common burnt clay building sub class 'B' bricks, laid over sand cushioning laid at right angle along with cable including taking out old one complete all as specified and as directed.
Returning, filling in, excavated soil in trenches, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removal of excavated any type of soil to a distance not exceeding 50m complete all as specified and as directed.
Supply ,laying and replacement of GI light graded of size 40mm including all accessories for encasing cables for mechnaical protection, laid under plinth / floors / path culverts with complete accessories such as bends / sockets / reducers / saddles including necessary threading / drilling works complete all as specified and as directed . (M.S. work will be measured under separate item in schedule).
S&F ceiling rose, 3 terminal surface type complete all as specified and as directed.
S&F switch piano, flush type single pole one way 5 Amp, 240 Volts complete all as specified and as directed.
Supply and fixing exhaust fan steel body AC single phase, 230V of size 30mm sweep with blades, frame and louvers complete all as specified and as directed.
Making holes for 300mm dia exhaust fan of suitable shape and size into or through brick wall at ground floor / any floor (1 to 3) including plastering on both sides of wall (internal and external) for making good to the original surface of any description including painting / distemper to plastered wall matching with existing colour complete all as specified and as directed. Note: - Rates are deemed to be including charges of any type of T&P, insurance of staff deployed at site.
Supply and fixing Desert cooler (steel body) AC 1000 rpm, 230 Volts, 1/6 HP motor capacity complete all as specified and as directed. Note: - Above said rate is inclusive of iron cooler stand of appropriate size as per requirement at site.
Supply and fix metal body water heater storage type (Geyser) 25 Ltr capacity, confirming to ISI, single phase with working voltage 240 Volts, 50 Hz including safety valve complete all as specified and as directed. Note: - (a) The housing for heating element and thermostat are to be separate. (b) Rates are deemed to be inclusive of cost for fixing of 4 No's of rawl plug of suitable size (4" to 6") buts and bolts, grouting work in RCC / Brick wall.
M&L point wiring independent taking direct from existing main DB installed at entrance complete using with 4.0 Sqmm (nominal area), PVC insulated, multistranded, unsheathed, copper conductor cables drawn through and including concealed in PVC conduits with all accessories complete fixed to walls / ceiling etc with and including 4.0 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including 1.6mm thick mild steel sunken boxes of suitable size with 3mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light / fan / bell point controlled by one, one way switches complete all as specified and as directed.
S&F switch socket combination 2-in-1, 5/16 Amps, 5 in 1, flush type with fuse and neon indicator complete all as specified and as directed by Engineer-in-Charge.
M&L for cutting to existing pipe 15/20mm dia in position and insertion of T, additional alteration in position complete with GI fittings as required at site for connecting new GI pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Galvanised iron pipe medium grade of size 15mm complete with all fittings such as bend, tee, reducer, elbow and union of required size and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed. Note: - Rates are deemed to be included for fixing of MS clamps of suitable size to hold the GI pipe.
Supply and fix gun metal or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15mm dia complete all as specified and as directed.
M&L PVC connection pipe heavy duty ISI marked (Hot or Cold) of 15mm size with PTMT nuts of length 350-450mm from GI pipe to Geyser input and output complete all as specified and as directed.
Supply and fix Bib tap fancy type cast copper alloy with crutch or butterfly handle, screwed down for iron pipe 15mm dia complete all as specified and as directed.
S&F MCB single pole neutral 240 Volts, 40 Amps, 'B' series, 10 KA complete all as specified and as directed.
M/s Sahib Construction and engineers
M/S ASHOK KUMAR SURI
M/S STAR CONSTRUCTIONS
M/S LANGER CONSTRUCTION COMPANY
Pyramid constructions
Bidder Name
Sarbat Construction Co
M/s Sahib Construction and engineers
M/S STAR CONSTRUCTIONS
Pyramid constructions
M/S ASHOK KUMAR SURI
M/S LANGER CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .