Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC 79 B BLOCK SRI GANGANAGAR 335001 RAJASTHAN | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹23.7 L+₹65,219.30 (2.83%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹24.1 L+₹1.0 L (4.47%)Rejected-Finance 51 HANUMAN COLONY GALI NO 4 CHAK 5 E CHHOTI SRI GANGANAGAR RAJ | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹24.2 L+₹1.1 L (4.89%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹25.0 L+₹2.0 L (8.75%)Rejected-Finance | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Jul 2022, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIRS TO FALSE CEILING, PLASTERING AND ROOF TREATEMENT ETC OF TECHNICAL BUILDINGS AT LALGARH JATTAN MILT STN.
2022_MES_527668_1
8933-17/22-23
Open Tender
Coal Works
Item Rate
180 days
GE Lalgarh Jattan
Class E Cat a (i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹50,000
21 Sept 2022
1 Jun 2022
30 Jul 2022
1 Jun 2022
27 Jul 2022
17 Jun 2022
Amount
Dismantling asbestos cement (corrugated / semi corrugated) sheets including ridges as in roof covering all as specified & directed by Engineer-in-Charge.
S & F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Demilition of brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work in full brick thick wall using Fly Ash bricks (old size bricks) straight or curved on plan to any radius built in cement mortar (1:6) complete all as specified & directed by Engineer-in- charge.
M&L for raking out joints / pointing to brick work in roofs, incl cleaning the roof surface complete all as specified and directed by Engineer-in-charge.
M&L for flush pointing in cement mortar (1:3) mixed with 5% of crude oil by weight of cement to brick tiles on roof complete all as specified and directed by Engineer-in-charge.
S&F armstrong mineral fiber accoustical suspended ceiling system with ANF(Micro look) EGE tiles with arm strong silhouette exposed grid. The tiles should have humidity resistance (RH) of 90%. NRC 0.5%. Light reflectance shall be more than 85% thermal conductivity K=0.052-0.057 w/mk. colour shall be white, fire perfomance class 0/class 1 (BS 4760 in module size of 600mmx600mmx15mm with bioblock coating on the face of tiles. suitable for green building application with recycle content of 63% the tiles shall be laid on arm strong silhouette profile grid system with 15mm with flanges incorporating 6mm central revel in white/black colour and with a web height of 45mm and and load carrying capacity of minimum 15.68kg/sqm.silhouette , main runner and cross runner shall have mitred end and birdsmouth notches to provides mitred juction. the Tee section hace a galvanised of 125gms/sqm complate all as specified and directed bu Engineer-in-charge.
Taking down cement plaster from brick wall or concrete surfaces or ceiling including raking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed
M&L rendering 15mm thick cement plaster on brick walls or concrete, surface in cm 1:6 and surface to be finished even smooth without using extra cement complete all as specified & directed
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 and finished fair and even including mixing of WPC in mortar complete all as directed
M & L rendering 5 mm thick in cement mortar (1:3) on fair faces of concrete surfaces of ceiling finishedeven and smooth without using extra cement complete all as specified & directed by Engr-in-charge.
M&L preparing newly plastered or pointed surface of wall and applying 2 coats of oil bound distemper on walls over a coat of primer complete all as specified & directed
M&L preparing newly plastered or pointed surface of ceiling and applying three coats of white wash on ceiling complete all as specified & directed
M&L for preparation of new plastered or pointed surface of walls and applying two coats of cement base paint complete all as specified & directed
Dismantling of brick tiles in floor laid, bedded and pointed in any mortor complete all as specified and as directed by engineer-in-Charge.
Demolition mud in roofs, any thickness, including plastering and leeping complete all as specified and directed.
M&L for 50 mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in roof padding etc and slope 1:40 complete all as specified
M&L for Roof treatment to RCC roof as follows:- (a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge. Make : STP Dr Fixit/Pidilite, Texsa India Ltd/Tikitar Dansona/Bengal Bitumen Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk.
M & L for cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry, with grey cement and no pigment in floors/roof, and cut and polished complete all as specified and directed.
M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, and like rounded or chamfered on edges including necessary form work etc complete all as specified & directed by Engr-in-Charge.
Material and labour for repair to damage RCC coloumns/Beam/Slab/Chajja by using micro mortar and concrete in Following Stages :- (a) Removing the mortar and loose concrete from RCC elements. (b) Cleaning the rusted reinforcements and applying rust removal. (c) Inserting the addl reinforcements in cape the coves sectional area reduction in more than 20 percent welding the reinforcement with existing area and supporting adequate on walls if reqiurd with grout. (d) Providing micro morter and concrete over bond coat to cover the reinforcements and slet surface. (e) Providing adequate from wave and scaffolding if required. (f) Curing the surface. Note :- (i) Rust removal, bonding agent, grout, micro morter and concrete and related chemicals shall be of Dr Fixit/BASF and STP (ii) Work is to be got executed from authorised applicator of he manufacturer. (iii) Steel shall be measured and paid separately
M&L applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm as in roof including cleaning surfaces all as specified and directed
Supply only integrated water proofing compound complete all as directed by Engr-in-charge. Make:- Dr Fixit/Fosroc/BASF/STP.
Disconnecting existing tanks capacity exc 250 and n exc 500 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
Disconnecting existing tanks capacity exc 500 and n exc 1000 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
S & F in repairs ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms)
S & F in repairs connection Nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms)
Taking up or down steel tubing 20mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed
Taking up or down steel tubing 15mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed
Taking up or down steel tubing 25 mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed
S&F 25 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as directed.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as directed.
S&F 20mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as directed.
Dismantling of water tanks of capacity exc 250 and n.exc 500 ltrs and removing from site all as specified and directed.
S&F for Rotational moulded polythene water storage tank 500 ltr capacity vertical with closed top hoisted and fixed in position all as specified in SSR part-I. All as directed and including 20 mm bore PTMT float valve, connection nipple 2 Nos complete all as specified and directed..
Dismantling of water tanks of capacity exc 500 and n.exc 1000 ltrs and removing from site all as specified and directed.
S&F for Rotational moulded polythene water storage tank 1000 ltr capacity vertical with closed top hoisted and fixed in position all as specified in SSR part-I All as directed and including 20 mm bore PTMT float valve, connection nipple 2 Nos complete all as specified and directed..
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed in repair all as specified and as approved by GE/Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overalll as fixed along the cente line over fittings and accessories)
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls all as directed.
Supply & fixed Clamp for hanging/ fixed of 75mm/100mm hubless pipes complete all as specified and directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and conforming to Fe 410 -W (Gde- E- 250) quality- A.
M&L preparation of new steel surfaces over 10cm in width or girth & applying 2 coats of synthetic enamel paint over a coat of red oxide primer.
S & F in repairs Vitreous China urinals white, half stall complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing with brackets, grating and Union for discharge pipe complete all as specified and directed.
S&F in reapirs Wash basins, Vitreous China white, size 550x400 mm, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe all as specified and directed.
S & F in repairs PVC Flushing cistern 10 ltr capicity valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S & F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests complete including provision of cemeny concrete bedding complete all as specified and directed.
S&F in repair pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified and directed.
S&F in repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, hand operated, screwed for iron pipe or for brass ferrule all as specified.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm all as directed.
S&F in repair tubular towel rail, Brass chromium plated 20 mm dia, 'D' type, 60cm long between flanges complete all as specified and as directed by Engineer-in-Charge.
S&F in repair CP brass stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup fixed all as specified.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar complete all as specified and as directed.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in dado/skirting over and including 10 mm thick rendering on vertical surface in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and directed.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450 x 300 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as directed.
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as directed.
M&L for 100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.
M&L Machine pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with over Fazilka sand cushion and incl dismantling all as specified and directed. (Sand will be measured and paid seperatly)
Suply only fine aggregate (sand) for cushioning (Fazilka sand) all as specified and directed
S&F in repair, shower rose, 125 mm size, brass chromium plated with sweivel joint all as directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M/S BUDHRAM BISHNOI
SHIVA CONSTRUCTION COMPANY
Aggarwal brothers and company
GOYAL ENTERPRISES
Akarsha Enterprises
AJAY CONSTRUCTION COMPANY
Dashmesh Construction Company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .