| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹12.6 L+₹73,133 (6.15%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹13.4 L+₹1.5 L (12.5%)Rejected-Finance B 1 2 MAHESH NAGAR AMBALA CANTT 133001 HRY | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹13.6 L+₹1.7 L (14.3%)Rejected-Finance 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹14.4 L+₹2.5 L (21.4%)Rejected-Finance SR NO 165 OPPOSITE YASH HOSPITAL DP ROAD MALWADI PUNE MAHARASHTRA 411028 | PUNE | MAHARASHTRA | 411028 | L5 | Rejected-Finance High Rate |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
19 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Pune
Arjun Marg Pune
8296 ADDN ALTN TO BLDG NO P70 (OFFRS STUDENT LIVING ACCN) AT AIPT UNDER AGE BR II GE (CENTRAL) PUNE .
2022_MES_519385_1
8296 ADDN / ALTN TO BLDG NO P-70 (OFFRS STUDENT LI
Open Tender
Civil Works
Item Rate
150 days
GE (Central) Pune
As per NIT
8 documents required · 8 mandatory
₹500
GE (Central) Pune
₹29,000
Yes
9 Jul 2022
22 Apr 2022
21 May 2022
22 Apr 2022
19 May 2022
6 May 2022
60 days
Amount
Taking down chowkat exc 1.5 Sqm but n.exc 4 sqm each (without taking off shutters from the frame). complete all as specified and as directed
Taking down Chowkats or frames not exc 1.5 Sqm each (without taking off shutters from the frame). complete all as specified and as directed
Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each complete all as specified and as directed
S & F for 2nd Class hardwood in Plain , solid, straight chowkats and frames , wrought, framed open rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as directed.
S&F three track sliding window & ventiltors with two or more shutter with including using 5 mm thick tinted glass and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S&F aluminium powder coated frame for doors & windows,Shutters ventilators, with one or more rebates including joining cleat for fixing etc complete all as specified and directed
S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, one face is covered with decorative face veneer with lipping/frame to match complete as directed
Supply and fixing factory Made 2nd class hard wood 35 mm thick glazed and skelton shutters open rebated and prepared to receive gauge. (Without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a) complete all as specified.
S&F in repairs stainless steel Wire cloth 0.56mm nominal dia of Wire and average Width of aperture 1.18mm and fixed with stainless steel stapple/ wooden beads to steel or wooden windows/door/shutters/frames etc. complete all as specified and as directed
S & F 18/19 mm thick prelaminated PVC Mouleded cupboard shutter/frame/shelving / cabinate and showcase cupboard etc complete all as specified and as directed
S&F continuous (Piano) hinges, mild steel bright finished or electro galvanised width of flap 30mm
S&F aluminium anodised barrel tower bolts of extruded section 150 mm long
S&F aluminium anodised handles, fabricated type of size 150 mm
S&F Megnetic catcher for cabinets all as specified and directed
S&F hasp and staple safety type aluminium with steel hinge pin incl bolt to hinge plate and fixed witth screws of 125mm in size
S&F butt hinges 100mm size MS cold rolled medium weight all as specified.
S&F aluminium alloy sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section etc length of bolt 300 mm long.
S&F MS framed work such as grills , grating with ends of bar shoudered and/or riveted or forged into spikes , framed Guard bars, railing and likes etc conformed to Fe-290, Gde-E-165 of MS angle or other section complete as directed .
M/L for preparation of new steel iron surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide zinc primer all as directed
S&F for preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed
Preparing old painted wooden surfaces of any description, over 10 cm width or girth and applying one coats of synthetic enamel paint all as directed.
M&L preparation Old steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint all as specified and directed.
Demolition of brick work or stone/boulder masonary built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and precast PCC block including rubbish off premises complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc in cement mortor of any description complete all as directed.
M&L for precast cement concrete block masonry not exceeding 10cm in width with solid blocks of PCC (1:5:8) gde D-4 and setting in CM 1:4 all as directed.
M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) gde D-5 and setting in CM 1:6 all as directed..
M&L for rendering 15mm thick cement plaster 1:4 on fair faces of concrete surfaces of wall finished with sponge finish all as specified and directed.
M&L for 10mm thick plastering in CM 1:6 on concrete on fair faces of bricks or concrete surfaces of wall finished even smooth with layer wall care putty complete all as specified and directed.
M&L for 5mm thick plastering in CM 1:3 on concrete on fair faces concrete surfaces of ceiling finished even smooth with thin layer of sagol finish complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm all as specified and directed.
M&L for preparation of new plastered surface and applying two coats of oil bound distemper over a coat of primer on ceiling all as specified and directed.
Demolation of stone slab/tiles of any description or thickness laid, bedded and pointed in cement mortar/in floor, skirting, hard standingg, Apron etc
M&L for 20 to 25mm thick machine cut Kota stone (550 x 550 mm) in flooring laid and jointed with grey cement slurrry mixed with pigments to match the shade of the slab including rubbing and polishing upto entire satisfaction of Engineer-in-Charge complete all as specified over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed
M & L for machine grinding / polishing of existing kota stone flooring including riser of steps, skirting with Fine Grade (No. 120) , applying oxalic acid ,wax polish to obtain mirror polish finished all as specified and as directed
M/L for pre polished both side cuddappa stone slab 30 to 40 mm thick as in partition/ support for platform fixed in position.
M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms ,shelve and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and as directed
Supply and fixed kitchen or laboratory sinks with drainage board made of stainless steel 1mm thick with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified.and directed
S&F in repair, 15mm dia Angular stop cock with wall flange cast copper alloy chromium plated fancy type screwed down high pressure with crutch or buterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F Stainless steel Plate rack made of sheet grade SS-304, thickness not less 0.63mm of standard size (36” x 36” x 10”) & approved quality of finish, complete all as specified & directed.
Taking up or down steel water tubing and connection including cleaning for refixing or removal to store of 15mm bore all as specified.
Ditto as per item 41 above but of 20 bore all as specified.
S&F in medium grade galvanised GI pipe with all fittings and fixed complete to walls and ceilings or laid in floors of followig sizes :- .
(a) 15mm bore dia
(b) 20mm bore dia
Refixing old steel tubing and connections in new or old postion (wall/floor/ceilings etc) of following size :-
(a) 15mm bore dia
(b) 20mm bore dia
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
S&F aluminium powder coated fancy type curtain rod 20mm bore all as specitied & directed
S&F aluminium powder coated fancy type brackets complete all as specified and directed.
M & L Cutting holes in brick/stone walls in Cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as directed
S&F in repair CP Brass long body bib cock 15mm of make Perrywere or equivalent make given as in Appx A complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as directed
M&L for PCC (1:2:4) type B0 25 mm thick (12.5 mm graded aggregate) in floor to receive top layer like tiles etc complete all as specified.
M&L for Glazed Coloured ceramic tiles in verticle surfaces 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick plaster in C:M 1:4 as abacking coat with filleting trangular shape on top of tiles etc completed all as directed
M&L for coloured non-skid tiles 400x400x7 to 8mm thick (square/rectangular) in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in cement mortar 1:6 complete all specified.
M & L for surface excavation n. exc 30cm deep and averaging 15cm deep and getting out Soft/loose soil Complete all as specified
M&L for broken hard core gauge, n exc 63mm deposited spread and leveled in layers n.exc 15cm thick water and rolled/rammed true surfaces complete all as specified
Demolition of cement concrete in ground floor and paving not exc. 15 mm thick (below or above ground level) all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-2 (using 20mm graded aggregate) as in plinth protection/Hardstanding, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
Removing of existing old bitumenous tarfelt including cement screed bed and clean the surface with wire brush and washing with water to achieve the original surface of slab all as specified and directed.
Demolition of cement concrete of any description and in any position on roof slab as in padding/mud phuska etc complete all as specified and directed.
M&L PCC 1:2:4 type B-0 using 12.5 mm graded stone agg asin PCC padding in roof kerbs or mud stops, rounded and chamfered on edges and on chajjas laid over RCC surface fineshed enen and smooth without using extra cement including necessary water liqual proofing chemicals @ 200ml per by of annxure all as specified and directed by the Engr-in-charge. (Note: WPC shall be measured and paid separately)
Supply only liquid water proofing chemical
M & L water proofing treatment to RCC roof slab, walls, chajjas ets, shall be carried out as specified below :- . (a) M&L for 10mm thick plaster screed bed layer in CM 1:3 on concrete surfaces. (b) Preparing plastered surfaces of roof slab, walls, chajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bitumnous primer @ 0.20kg/Sqm of area complete all as specified. (c) Laying App polymer modified approved membrane, non woven, polyester, weighing not less than 3.6kg/Sqm and 3mm thick with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. (d) Carrying out test by flooding water for 24 hrs for leakagge & seepages and rectifying the same to the entire satisfaction of GE. (e) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 Ltr/Sqm on the top of membrane surfaces including taking down old waterproofing treatmentcomplete all as specifed & as directed by Engr in Charge.
Dismantling existing water storage tanks of any capacity not exc. 1000 ltrs and setting aside, . (Note :-Necessary arrangement for w/s to be done by the contractor till completion of roof work)
Disconnecting existing water tank exc of 2000 Ltr capacity , setting aside (or lowering if required) for repairs , cleaning etc and hoisting , refixing and reconnecting in position if required after completion of roof repairs complete all as specified and directed.
Supply and Fix rotational moulded polythylene water storage tanks, 2000 Ltrs capacity, (Cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old broken/damaged PVC water tank complete all as specified and directed.
M&L PVC (SWR) floor trap with steel grating 75mm dia including jointing to waste pipe traps complete.
M/L in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors as specified and directed
M/L in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors as specified and directed
S&F PVC (SWR) bends plain 75mm bore dia
S&F for 75mm dia SWR junction (single 'T') equal or unequal with door access.
S&F PVC (SWR) bends plain 110 mm bore dia
S/F PVC (SWR) Branch piece single (single Y) equal or unequl 110mm dia with door access
Complete removal of existing treatment, M&L for applying applying two coats of oil bound distemper on walls over a thin layer of wall care putty and all as specified and directed.
M&L for preparation of old plastered surfaces of wall and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position including rubbish off outside of MOD land complete all as specified and as directed.
M& L RCC Type B1 1:2:4 (20 mm graded stone aggregate ) Nominal mix for Chajja,suspened slab,landing complete all as specified and as directed.
M&L Mild steel TMT bars 10mm dia and over , cut to length, bent to shape required including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) 0.9mm dia or securing with clips etc complete all as specified
Cutting holes into or through Stone walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 with using liquid water proffing compound @ 200ml per bag of cement , superfacial area exc 150 sq. cm but n exc 400 sqcm all as specified and directed.
Taking down old u/s point wiring( light/fan/socket/power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, pendants, regulators, light fittings etc. removing materials for taking credit and making good the disturbed surfaces of walls/floors/ceiling etc.complete all as specified.
Taking down Main switches/DBs of any make and type including teak wood board, MCBs/MCCBs etc. complete and making good the disturbed surfaces including colour wash complete all as specified.
Taking down ceiling fan/ exhaust fan/Wall fan of any sweep, keeping with safe custody and refixing the same with replacement of 3 core PVC insulated PVC sheated multistranded copper conductor cable of size 23/0.193 from ceiling rose to fan terminal after over hauling the fan, Painting of ceiling fans with one coats of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc. complete all as specified.
M&L for point wiring of any length using approved colour coding as per IS with stranded copper conductor 1.5 Sq.mm (Nominal area) single core, PVC insulated and unsheathed stranded FRLS copper cable 1100 volts grade, IS - 694 marked in PVC casing & caping heavy duty ISI marked including all accessories with PVC modular surface boxes inluding modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for the following:-
a) One light/fan point controlled by one, One way switch all as specified
b) One three pin 5 Amps socket outlet point controlled by one No one way switch on same board all as specified
c) One three pin 5 Amps socket outlet point controlled by one No one way switch on independant board all as specified
d) One bell/buzer point controlled by one bell push complete all as specified.
e) One light point controlled by two 2-way switches complete all as specified.
All as per item no. 86 above but with 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, IS - 694 marked, including PVC insulated stranded copper conductor 2.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 amps socket outlet point on independent board.
S & F modular switch 6A SP one way 230V, white / ivory finish complete all as specified
S & F modular switch 16A SP one way 230V, white / ivory finish complete all as specified
S & F modular socket outlet 2/3 pin 6 Amps, multipurpose 2 module 230 Volts, single pole, one way suitable for plug tops, complete all as specified.
S & F modular socket outlet 2/3 pin 16 Amps, multipurpose 2 module 230 Volts, single pole, one way suitable for plug tops, complete all as specified.
S & F modular switch 6A SP two way, 230V white / ivory finish complete all as specified
S&F ceiling rose surface type three terminals complete all as specified and directed.
S & F Modular type stepped electronic fan regulator, 1 to 5 steps all as specified & directed
S&F lamp holder (angle) insulated body, with back plate including LED bulb of cap 12 Watt 2 pin type complete for 230 V 50Hz AC supply all as specified.
Supply and fix LED Tube light fittings Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver 10 W LED complete including all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector. Conforming to Cat Part No.ENDURALINEARNEOBS10WLED865SPCWH Make :- Havells or Equivalant as given in Appx 'A'
Supply and fix LED Tube light fittings Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver 20 W LED complete including all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector. Conforming to Cat Part No.ENDURALINEARNEOBS20WLED865SPCWH Make :- Havells or Equivalant as given in Appx 'A' .
M & L for Sub main wiring with 2 runs of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through non-metallic 20 mm PVC rigid, ISI marked and its accessories duly in PVC Casing & Caping on wall/ roof including one run of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor complete including taking down old submain wiring all as specified. Note:- Two run of 4 sqmm conductor & one run of 4 sqmm conductor will be measured as on RM
M & L servicing of geyser of 1.5/2 KW capacity, including cleaning, overhauling, spray painting with one coat of synthetic enamel paint including writing MES no and refixing the geyser toits original position all as specified.
S&F MCB TPN DB 4 way double door with 200 Amps rated busbar 415 V, all as specified.
S&F MCB SPN DB 8 way, double door, with 200 Amp rated busbar 240 V, all as specified.
S & F for MCB Single pole rated capacity 6 to 32 Amps, 240 V breaking capacity , 10 KA , C- curve complete all as specified.
S & F for MCB double pole of rated capacity 32 Amps, 240 volts breaking capacity 10 KA, C-curve complete all as specified.
S & F for MCB four pole of rated capacity 63 Amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified.
M & L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part - I including RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete (Note:-GI earth wire and protection pipe beyond 7.5m will be measured and paid separately)
Agarwal Agencies
ANIL CONSTRUCTION CO.
SBS Enterprises
M/S P D TUPE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .