| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER. | |
| 2 | L2₹25.8 L+₹3.9 L (17.6%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 3 | L3₹33.3 L+₹11.3 L (51.5%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L3 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 4 | L4₹37.4 L+₹15.5 L (70.6%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER. |
| Sl No | Description | Qty | Unit | PURVA ELECTRICALS AND ENGINEERS L4 | M/S JEELANI ELECTRICALS L2 | Adinath Technical Services L3 | AMAN ENGINEERING AND ELECTIRICALS WORKS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install testing and commissioning in repair factory made out door type LT panel board of size not less than 1.5 mtrX1.2mtrX1 mtr, 440 volts , 3 phase , 4 wire system with powder coating provided to make it dust /vermin proo,f manufactured from CPRI approved manufacturer, The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 1.6 mm thick CRCA sheet,double door with front openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell be compartmentalized, front openable single door system lockable. Inner shell completely vermin proof and to accommodate incoming/outgoing ACB's, MCCBs, MCBs, and TPN aluminium bus and extension links. Aluminium bus bar of capacity 1200 Amps- 4Nos, including neutral duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/rating of epoxy resin insulator all housed in suitable bus bar chamber. All control wires shall be as per the OEM recommendations and shall be properly bunched,tied, ferrulled for proper indentification and crimped with adequate size of lugs and provision and fixing of Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable size of cable glands etc. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The panel shall consists of following accessories:-
Location :- Near 400KVA Transformer Aundh Camp. | 1 | Each Job | 5,40,000 ₹5,40,000 | 3,75,000 ₹3,75,000 | 6,42,279 ₹6,42,279 | 2,50,000 ₹2,50,000 Lowest |
| 1.01Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 65mm x 65mm x 6mm with bottam of panel having minimum 60cm height from existing ground/floor level. (vii) The operation of all MCCBs should be of Rotary handle type, the cost of rotory handles is deemed to be included in the quoted cost. | |||||||
| 1.02Aluminium bus bar strips with proper colour code -04 No, 1200 A cap, insulator, nuts bolts etc complete. | |||||||
| 1.03Indicator Lamp-01 Set (Set of three) | |||||||
| 1.04Incommer ACB 800 Amps Manual draw out type , 50 KA 4 pole 415 volts - 01 Nos Make :- Legrand cat no -DMXS108N3MD4N or Havells cat no- IHAFE21060080 | |||||||
| 1.05Outgoing, MCCB 4P 400 amp with thermal magnetic release , 415V, 36 KA - 01 No (for APFC panel) Make Legrand cat no-4220 07 or Havells cat no- IHLLSEE40400 | |||||||
| 1.06Outgoing, MCCB 4P 250 amp with thermal magnetic release , 415V, 36 KA - 04 No (for Feeder panel) Make Legrand cat no-4220 49 or Havells cat no- IHLLSEE40250 | |||||||
| 1.07Outgoing, MCCB 4P 125 amp with thermal magnetic release , 415V, 25 KA - 02 No (for Feeder panels of Md accn) Make Legrand cat no-4200 56 or Havells cat no- IHTT1DBF0125 | |||||||
| 1.08Outgoing, MCCB 4P 100 amp with thermal magnetic release , 415V, 25 KA - 01 No (for mobile towers panel) Make Legrand cat no-4200 55 or Havells cat no- IHTT1DBF0100 | |||||||
| 1.09Outgoing, MCCB 4P 63 amp with thermal magnetic release , 415V, 25 KA - 01 No (for Street light panel) Make Legrand cat no-4200 53 or Havells cat no- IHTTHDB40063 | |||||||
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
21 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPLACEMENT OF OLD LT DISTRIBUTION PANELS AND CERTAIN REPAIRS TO E/M INSTALLATIONS OF AUNDH MILITARY CAMP UNDER GE MH RH KHADKI
2025_MES_733578_1
8780/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹70,000
Yes
20 Dec 2025
1 Oct 2025
23 Oct 2025
1 Oct 2025
21 Oct 2025
14 Oct 2025
1 Oct 2025 - 21 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
TENDER8780.pdf
Tender Documents • 0.79 MB
BOQ_821376.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .