Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.2 L+₹49,734.40 (1.19%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹42.8 L+₹1.1 L (2.72%)Rejected-Finance | L3 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | chowdeshwariconstructionco L1 | VARGHESECHACKO AND CO L3 | M/S AMRITHESH ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out hard soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. | 100 | Each | 200 ₹20,000 Lowest | 385 ₹38,500 | 200 ₹20,000 Lowest |
| 2.00 | Excavation in trenches exceeding 1.5 m deep and not exceeding 3m depth for pole and getting out in hard soil, all as specified and directed. | 6 | CUM | 600 ₹3,600 | 500 ₹3,000 Lowest | 650 ₹3,900 |
| 3.00 | Returning and filling in soil including spreading leveling watering and well ramming in layers not exceeding 25cm, complete all as specified and directed. | 0.96 | CUM | 110 ₹105.6 Lowest | 900 ₹864 | 350 ₹336 |
| 4.00 | Removing surplus excavated material to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 M above the starting point, complete all as specified and directed. | 5.04 | CUM | 150 ₹756 Lowest | 900 ₹4,536 | 1,500 ₹7,560 |
| 5.00 | Material & Labour for Sand as sand cushioning for laying of interlocking tiles complete all as specified and directed. | 5.25 | Cum | 1,800 ₹9,450 Lowest | 1,800 ₹9,450 Lowest | 2,300 ₹12,075 |
| 6.00 | Material & Labour for hand packing broken stone or boulders (any thickness) at back of walls over arches and raising (or lowering) to the required level, complete all as specified | 27 | Cum | 1,800 ₹48,600 Lowest | 2,500 ₹67,500 | 2,000 ₹54,000 |
| 7.00 | Material & Labour for hard core of broken bricks gauge not exceeding 63 mm, deposited spreaded and leveled in layer not exceeding 15 cm thick, watered and rammed to atrue surface, broken stone or boulder, complete all as specified and directed. | 19 | Cum | 850 ₹16,150 Lowest | 4,000 ₹76,000 | 2,300 ₹43,700 |
| 8.00 | Material & Labour for graded crushed stone ggregates for loose filling, of gauge 40 to 80mm graded, all as specified and directed. | 10 | Cum | 1,800 ₹18,000 Lowest | 4,500 ₹45,000 | 2,200 ₹22,000 |
| 9.00 | Material & Labour for Plain Cement Concrete 1:4:8 type D-2 (using 40mm stone aggregate) in foundation and filling in mass concrete, complete all as specified and directed. | 19.16 | Cum | 4,800 ₹91,968 | 5,000 ₹95,800 | 2,800 ₹53,648 Lowest |
| 10.00 | Material & Labour for Plain Cement Concrete (1:2:4) Type B-1 (using 20 mm graded aggregate) for coping of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site. | 0.5 | CUM | 7,000 ₹3,500 | 6,000 ₹3,000 Lowest | 6,500 ₹3,250 |
Tender Value
₹43.2 L
EMD Value
₹86,500
Closing Date
6 Aug 2025, 6:00 pmClosed
Ranjeet Kumar, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPECIAL REPAIR TO MES INFRASTRUCTURE AT AFS CHIMNEY HILL
2025_MES_719293_1
82179/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) (AF) Chimney Hills
As per Tender Document
7 documents required · 7 mandatory
₹500
Yes
AGE (I) AF Chimney Hills
₹86,500
Yes
1 Sept 2025
9 Jul 2025
13 Aug 2025
9 Jul 2025
6 Aug 2025
23 Jul 2025
9 Jul 2025 - 14 Jul 2025
Amount
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out hard soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
Excavation in trenches exceeding 1.5 m deep and not exceeding 3m depth for pole and getting out in hard soil, all as specified and directed.
Returning and filling in soil including spreading leveling watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 M above the starting point, complete all as specified and directed.
Material & Labour for Sand as sand cushioning for laying of interlocking tiles complete all as specified and directed.
Material & Labour for hand packing broken stone or boulders (any thickness) at back of walls over arches and raising (or lowering) to the required level, complete all as specified
Material & Labour for hard core of broken bricks gauge not exceeding 63 mm, deposited spreaded and leveled in layer not exceeding 15 cm thick, watered and rammed to atrue surface, broken stone or boulder, complete all as specified and directed.
Material & Labour for graded crushed stone ggregates for loose filling, of gauge 40 to 80mm graded, all as specified and directed.
Material & Labour for Plain Cement Concrete 1:4:8 type D-2 (using 40mm stone aggregate) in foundation and filling in mass concrete, complete all as specified and directed.
Material & Labour for Plain Cement Concrete (1:2:4) Type B-1 (using 20 mm graded aggregate) for coping of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
Material & Labour for Plain cement concrete 1:3:6 type C-1(using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete, all as specified and directed.
Material & Labour for pre cast cement concrete solid block masonry 1:3:6 type C-1(using 20mm aggregate) with solid block exceeding 10cm in width setting in cement mortar 1:4 complete all as specified and directed.
Supply only Integral waterproofing compound, complete all as specified and directed.
Material & Labour for walling of random rubble masonry uncoursed, well bonded and solidly hearted built in cement mortar 1:4 complete all as specified and directed.
Walling of random rubble masonry un coursed well bonded and solidly hearted built in cement mortar 1:4 except stone, complete all as specified and directed.
Taking down chowkats or frames with shutters ( without taking of shutter from the frame) not exceeding 1.5 Sqm each, complete all as specified and directed.
Taking down chowkats or frames with shutters ( without taking of shutter from the frame) exceeding 1.5 Sqm but not exceeding 4.00 sqm each, complete all as specified and directed.
Material & Labour for Rubber gasket EPDM / Neoprene for fixing glass pane in aluminium frame work / door / window complete all as specified and directed.
Material & Labour for 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats all as specified and directed.
Material & Labour for 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. ( without sash bars) sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), fitted to chowkats, all as specified and directed.
Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: (i) For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. (ii) Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelaminated colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete (Pattern, shape & colour approved by AGE(I)) all as specified and directed.
Supply and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded prelaminated colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelaminated PVC colour sheet , stile and rails feathered edges for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of prelaminated PVC colour sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame, complete all as specified and directed. Note - Pattern, shape & colour shall be as approved by AGE(I)
Supply and fixing Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 140mm long, complete all as specified and directed.
Supply and fixing Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and directed.
Supply and fixing 100mm MS butt hinges cold rolled mild steel, complete all as specified and directed.
Supply and fixing Aluminium anodised, barrel tower bolts 150mm of extruded section, complete all as specified and directed.
Supply and fixing Aluminium anodised, handles 150mm of extruded section, complete all as specified and directed.
Supply and fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
Supply and fixing in repair for Drapary rod 20mm dia, mild steel, chromium plated with fixing brackets, stops etc all as specified and directed.
Supply and fixing in repair Brackets suitable for drapary rod, mild steel, chromium plated etc all as specified and directed.
Supply and fixing in repair for 15mm CP towel rail of 20mm dia with hook 600mm long complete all as specified and directed.
Material & Labour for Steel work in tublular truesses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240 complete all as specified and directed.
Material & Labour for Pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed
Material & Labour for Pressed steel frames 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, complete, as specified, supplied and fixed
Material & Labour for Powder coated aluminium frames and shutters/grills for door and window, ventilator or framing/partition with one or more rebates joining cleat for fixing etc of any thpe, side hung shutter, sliding shutters etc complete all as specified and directed.
Material & Labour for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified and directed.
Supply only Chain link MS galvanisd fencing, any size or type, complete all as specified and directed.
Material & Labour for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
Supply and fixing in repair Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, complete all as specified and directed. (Note - each line wire to be measured).
Supply and fixing Prepainted Galvalume sheet aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of a colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Supply and fixing Prepainted Galvalume sheet aluminium zinc coating GI based plain steel sheet 0.50 mm thick of a colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Material & Labour for Applying Oil bound Bitumen primer @ 0.20 Kg/Sqm all as specified and directed.
Material & Labour fo APP minimum 4mm thick polymeric membrane minimum weighing not less than 4kg/sqm and reinforced with polyster nonwoven fabric matt(wt. not less than 150 gms/sqm) & applying a coat of blown hot Bitumen over the membrane @ 12.00 kg/sqm complete all as specified and directed.
Material & Labour for 25mm thick Plain Cement Concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in padding course, finished surfces even and rough for roof treatment, complete all as specified and directed.
Material & Labour for provinding 75mm thick cement concrete in 1:3:6 type C1, (using 20mm graded stone aggregate) finishing cement concrete surface even and fair without using extra cement as in plinth protection complete all as directed.
Material & Labour for 75mm thick Plain Cement Concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring complete all as specified and directed.
Material & Labour for Prepolished Chequered cement concrete tiles of size 30cm X 30cm X 25mm thick, set and jointed and pointed in neat cement slurry in floors with grey cement and pigments laid over 15 mm thich screed bed in cement mortar 1:6 complete all as specified and directed.
Material & Labour for provinding 100mm thick cement concrete in 1:2:4 type B1, (using 20mm graded stone aggregate) finishing cement concrete surface even and fair without using extra cement as in plinth, Path / hard standing, complete all as directed.
Material & Labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment, complete all as specified and directed.
Material & Labour for Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 complete all as specified and directed.
Material & Labour for Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 10mm thick rendering as in backing coat of cement mortar 1:4 complete all as specified and directed.
Material & Labour for Glazed ceramic coloured tiles of size 300 x 450 x 7mm / 350 x 450 x 7mm thick over and including 10mm thick rendering in cement mortar 1:4 as in backing coat for tiles in vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
Taking down cement plaster on brick work or stone walls etc incl raking out joints hacking for key scrubbng down with water, complete all as specified and directed.
Material & Labour for cement mortar1:3 raised pointing to randam or polygonal rubble uncoursed or brought upto courses, complete all as specified and directed.
Material & Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth without using extra cement in internal surfaces, complete all as specified and directed.
Material & Labour for rendering 10 mm thick on ceiling as in chajja in CM 1:3 even and smooth without using extra cement complete all as specified and directed.
Material & Labour for 10mm thick plastering in cement mortar 1:3 on concrete surfaces finished even and smooth, complete all as specified and as directed.
Material & Labour for preparing new plaster surface apply two coat of oil bound distemper over a coat of wall care putty to obtained smoothness of wall surfaces over one coat of primer, complete all as specified and directed.
Material & Labour for complete remocal of plastered surface and apply two coat of oil bound distemper over one coat of primer over a coat of 3 mm thick wall care putty to obtain smoothness of wall surfaces, complete all as specified and directed.
Material & Labour for preparing new plaster surface and applying three coats of white wash ceiling surfaces, complete all as specified and directed.
Material & Labour for preparation and washing, rubbing down and stopping of distempered and painted surfaces of wall including cornices and applying two coats of acrylic distemper (ready mixed) having VOC content less than 50 gms / litre, of required shade and colour complete as per manufacturer's specification complete all as directed.
Material & Labour for preparation of old decorated surfaces of wall, pillasters, cornices etc and applying one coat cement base paint, complete all as specified and directed.
Supply and fixing Sheet glass 4mm thick, ordinary quality and glazing with oil putty or rubber gasket in square of any size in each pane, complete all as specified and directed.
Material & Labour for preparation wood surfaces over 10 cm width or girth and applying with two coats of Synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
Material & Labour for preparation steel surfaces over 10 cm width or girth with two coats of Synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
Dismantling of water tank and removing from site exceeding 500 ltrs but not exceeding 1000 ltrs, complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection including cleaning for re-fixing or removal from site, complete all as specified and directed.
Supplying and laying in repair of 25mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors, complete all as specified and directed.
Supply and fixing Rotational moulded polyethylene wate storage tanks of 1000 ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position including 20mm dia HD polythene float valve and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule, complete all as specified and directed.
Supply and fixing in repair for 75mm bore PVC (SWR) pipes single socketed any length with rubber ring joints laid in trenches / wall including taking down, complete all as specified and directed.
Supply and fixing for 75mm bore PVC (SWR) bends any radius including taking down, complete all as specified and directed.
Supply and fixing for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed.
Supply and fixing in repair for Vitreous china wash hand basin (550 x 400mm) white, flat back excluding taps, waster chain and plug and porcelain stopper but including brackets complete all as specified and directed.
Supply and fixing in repair for 32 mm bore waste fittings brass chromium plated for glazed ware sinks basins etc with long screwed shanks and fly nuts, flange and bedded in red lead cement, complete all as specified and directed.
Supply and fixing in repair for 15mm bore fancy type pillar taps cast copper alloy with capston head chromium plated screwed down high pressure with or without littred hot or cold with long screwed shanks and flynuts screwed for iron pipe, complete all as specified and directed.
Supply and fixing in repair for 10 ltrs capacity PVC valve less syphonic action type flushing cistern low level white inlet ball valve, float, flush pipe and handle incl brackets, complete all as specified and directed.
Supply and fixing in repair for PVC connection 15mm dia and 600mm long, complete all as specified and directed.
Supply and fixing in repair for PVC waste pipe 32 mm dia, complete all as specified and directed.
Supply and fixing in repair Stainless steel soap dish, fixed to plugs with chromium plated brass screws as specified and directed.
Supply and fixing in repair for Vitreous china squattng pan Orissa pattern size 580 x 440mm with white integral foot rest (excluding flushing cistern and flush pipe but including making good) complete all as specified and directed.
Supply and fixing in repair for Chromium Plated grating of size 100mm dia, complete all as specified and directed.
Supply and fixing 110 mm dia PVC (SWR) pipes single socketed fixed in walls / floors or in weep holes of retaining wall, complete all as specified and directed.
Supply and fixing in repair for 15mm bib tap Chromium Plated fancy type with crutch or butterfly handle screwed for iron pipe or for brass ferrules, complete all as specified and directed.
Supply and fixing in repair for 15 mm Chromium Plated, fancy type angle cock screwed for iron pipe or for brass ferrules, complete all as specified and directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, complete all as specified and directed.
Material & Labour for Point wiring for One light point controlled by one, one way switch with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn in and incl with multi stranded copper conductor drawn through and including suitable size Non metalic regid PVC conduit and all conduit accessories (concealed) and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor fabricated branded PVC Surface Box /Metal Concealed box of size 1.2 mm thickness concealed in walls with suitable Plastic/Sunmika outer cover with suitable screws for housing switches socket outlets fan regulators etc. all as specified and as directed.
Material & Labour for Point wiring for One Fan point controlled by one, one way switch with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn in and incl with multi stranded copper conductor drawn through and including suitable size Non metalic regid PVC conduit and all conduit accessories (concealed) and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor fabricated branded PVC Surface Box /Metal Concealed box of size 1.2 mm thickness concealed in walls with suitable Plastic/Sunmika outer cover with suitable screws for housing switches socket outlets fan regulators etc. all as specified and as directed.
Material & Labour for Point wiring for One Exhaust fan point controlled by one, one way switch with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn in and incl with multi stranded copper conductor drawn through and including suitable size Non metalic regid PVC conduit and all conduit accessories (concealed) and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor fabricated branded PVC Surface Box /Metal Concealed box of size 1.2 mm thickness concealed in walls with suitable Plastic/Sunmika outer cover with suitable screws for housing switches socket outlets fan regulators etc. all as specified and as directed.
Material & Labour for Point wiring for One wall fan point controlled by one, one way switch with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn in and incl with multi stranded copper conductor drawn through and including suitable size Non metalic regid PVC conduit and all conduit accessories (concealed) and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor fabricated branded PVC Surface Box /Metal Concealed box of size 1.2 mm thickness concealed in walls with suitable Plastic/Sunmika outer cover with suitable screws for housing switches socket outlets fan regulators etc. all as specified and as directed.
Material & Labour for Point wiring for One three pin socket outlet 5 Amp controlled by one, one way switch on independent board with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn in and incl with multi stranded copper conductor drawn through and including suitable size Non metalic regid PVC conduit and all conduit accessories (concealed) and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor fabricated branded PVC Surface Box /Metal Concealed box of size 1.2 mm thickness concealed in walls with suitable Plastic/Sunmika outer cover with suitable screws for housing switches socket outlets fan regulators etc. all as specified and as directed.
Material & Labour for Point wiring for One three pin socket outlet 5 Amp controlled by one, one way switch on same board with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn in and incl with multi stranded copper conductor drawn through and including suitable size Non metalic regid PVC conduit and all conduit accessories (concealed) and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor fabricated branded PVC Surface Box /Metal Concealed box of size 1.2 mm thickness concealed in walls with suitable Plastic/Sunmika outer cover with suitable screws for housing switches socket outlets fan regulators etc. all as specified and as directed.
Material & Labour for Point wiring for socket outlet 3 pin 15 Amps on independent board with 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn in and incl with multi stranded copper conductor drawn through and including suitable size Non metalic regid PVC conduit and all conduit accessories (concealed) and including provision of 2.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor fabricated branded PVC Surface Box /Metal Concealed box of size 1.2 mm thickness concealed in walls with suitable Plastic/Sunmika outer cover with suitable screws for housing switches socket outlets fan regulators etc. all as specified and as directed.
Supply and fixing in repair switch piano 6 Amps one way flush type, all as specified and directed .
Supply and fixing in repair switch piano 16 Amps one way flush type, all as specified and directed .
Supply and fixing in repair socket, 2 in 1, 3 pin 5 Amps flush type, all as specified and directed .
Supply and fixing in repair socket 2 in l, 3 pin 6 Amps and 3 pin 16 Amps flush type, all as specified and directed ..
Supply and fix in repair fan regulator AC 230 V electronic socket type, all as specified and directed .
Supply and fixing in repair ceiling rose 3 terminals, ISI Marked, all as specified and directed .
Supply and fixing LED lights fitting 1x 20 W of lumens 110 /Watt ,4 feet,220V, 6500 K,AC decorative box type with driver, holder including Retrofit LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
Supply and fixing LED light fitting integrated type with high out put diffuser 2 feet, 10 watt of lumens 100 /Watts,220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and directed .
Supply and fixing MCB SP 6 to 32 Amps10 KA 240V 50HZ, ISI Marked, all as specified and directed . .
Supply and fixing MCB SPN 6 to 32 Amps10 KA 240V 50HZ, ISI Marked, all as specified and directed . .
Supply and fixing RCCB, DP, 40 Amps AC type in accordance with IS:12640-1 and IEC-6100-1, suitable for 240 Volts, 50 Hz with 10 KA short circuit withstand capacity, all as specified and directed.
Material & Labour for Taking down existing Ceiling fan 1200/1400 mm sweep from its location Serviceing and Rewinding of ceiling fan/motor with super enameled copper winding wire of similar gauge and weight of the original winding insulating with class B, varnishing, drying,and relacing of capacitor,GM bushes,ball bearing,shakle etc complete, including refixing the same after carrying out the repair all as specified and directed.
Material & Labour for Taking down existing Wall fan any sweep from its location Serviceing and Rewinding of ceiling fan/motor with super enameled copper winding wire of similar gauge and weight of the original winding insulating with class B, varnishing, drying,and relacing of capacitor,GM bushes,ball bearing,shakle etc complete, including refixing the same after carrying out the repair all as specified and directed.
Supply and fix Exhaust fan,metal body ,AC single Phase. 230V of size 250mm sweep with 810CMH Air delivery ,37 W Consumption ,frame and louvers all as specified and directed.
Material & Labour for Making Hole in Stone wall for fixing of Exhaust Fan of 250 mm and Making Good disturbed surface by plastering and painting complete all as per directed.
Supply and fixing in repair MCB distribution board SPN 8 way single door 240V powder coated with 200 Amps rated bus bar neutral link etc, all as specified and directed .
Material & Labour for replacement of submain wiring /Circuit wiring with PVC insulated, single core, multi stranded, 1100 volts grade unsheathed copper conductor cable in and including PVC Conduit/Casing capping with accessories fixed on wall /ceiling with GI screws complete with 2x4 Sqmm +1x 4 Sqmm for earth continuity conductor, all as specified and directed . Note - 2 run of 4 Sqmm + 1 run of 4 Sqmm including PVC Conduit/Casing capping shall be measured as one unit
Material & Labour for replacement of submain wiring /Circuit wiring with PVC insulated, single core, multi stranded, 1100 volts grade unsheathed copper conductor cable in and including PVC Conduit/Casing capping with accessories fixed on wall /ceiling with GI screws complete with 4x4 Sqmm +1x 4 Sqmm for earth continuity conductor, all as specified and directed . Note - 4 run of 4 Sqmm + 1 run of 4 Sqmm including PVC Conduit/Casing capping shall be measured as one unit
Supply and fixing sheet metal enclosures with socket, plug top including MCB SP capacity 20 Amps all as specified and directed. .
Supply and fixing of 35 watts LED street light/ Security light fitting with pressure die cast IP 65 protection, luminous efficiency of 100 lm/watt, PF > 0.95, CRI > 80, colour temprature 5700 K suitable for primary roads with all connected accessories complete all as specified and directed.
Supply and fixing GI bracket in repairs made out of light grade pipe of size 40 mm dia 1.2 mtr long bent to shape including MS clamp of suitable size nut bolt washer for fixed along the wall/PCC polewith MS Clamp etc complete all as specified and directed.
Supply and fixing LED Solar street light fitting 20 Watt including galvanized steel pole in built,lithium ion battery, solar panel, charge controller with dusk down sensor, all as specified and directed. (Note - Excavation & earth work shall be measured separately)
Material & Labour for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 cm thick buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top level of earth plate at depth not less than 1.5 m below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 25x4mm GI strip by means of bolts, nuts, check nuts and washers of galvanized iron upto test point and protected by GI pipe light grade 40 mm bore up to 7.5 Mtr connected to a main switch board or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, 80 mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/Sqm in lieu of CI cover, PCC 1:3:6 type C2 pit / chamber including all necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in Electrical Plate No3 of MES Schedule Part – I of 2009.
Supply and fixing in replacement die cast aluminium IP66 LED Flood Light luminaire, 100 Watt capacity,efficacy 100 lumen/watt, Total Lumen 10000 Watt all as specified and directed.
Demolition of PCC block walling / brickwork masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of stone boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floor and paving not exceeding 15cm thick (below or above ground level) etc complete all as specified and directed.
Dismantling wrougt iron or mild steel work of any description not other wise privided for (steel gate & Y angles etc) including stainless steel letters in the board all as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, incl Nainital or similar pattern roof covering all as directed.
Dismantling old fencing , any type complete all as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section embedded in concrete brick work, masonry etc, including taking out embedded portion and making good disturbed ground.
M/S AMRITHESH ENTERPRISES (BID ID -3384937)
VARGHESECHACKO AND CO (BID ID -3377753)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .