Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹8,440
Closing Date
23 Nov 2020, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2020_PWDJK_109211_1
e-NIT No.EDJ/107 of 2020-21 Dated 13-11-2020
Open Tender
Electrical Works
Item Rate
35 days
Part B Govt Dental Hospital Jammu
please refer to NIT
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer PWD RandB Electric Div Jammu
₹8,440
Yes
26 Nov 2020
13 Nov 2020
24 Nov 2020
14 Nov 2020
23 Nov 2020
14 Nov 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.(in the existing pvc conduit and recssed metal boxes).
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire
2 x 6 Sq.mm + 1 x 6 Sq.mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in th existing surface/ recess PVC conduit as required.
1 x 1.5 Sq.mm
2 x 1.5 sq. mm
3 x 1.5 sq. mm
2 x 2.5 sq. mm
3 x 2.5 sq. mm
2 x 4 sq. mm
3 x 4 sq.mm
Supplying and fixing following rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 5/10/16 Amp
Single pole and neutral 32 Amp
SPN 40 Amp.
Triple pole and neutral 63 Amp
Supplying and fixing following modular type switch/socket on the existing switch box cover including connections etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box on surface in recess alongwith modular base & cover plate for modular switches in recess etc as required.
2 module
4 module
8 Module
12 Module
Supplying & fixing of 20/22 watt LED 4 feet tube light fitting/fixture CRCA housing with 2000 Lumens and min lumens efficiency 100 Lumens/watt P.F 70.95 THD < 16% & voltage input range 140-270 V with Shot circuit & overloading protection circuit off
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.
Ceiling fan 1200 mm sweep alongwith 1"-6" long fan rod.
Supplying and fixing of sheet steel panel indoor type wall mounted and having provision for 1 No. incomer MCCB and change over switch FP including proviidng and fixing of 300 Amp. aluminium bus bar 2 set and MCB strip for housing MCB's etc. as required.(3'-0x4'-0x1'-0)
Supplying and fixing MCCB in cubical panel board. Providing and fixing following rating and breaking capacity MCCB FP in existing cubical panel board including drilling of holes in cubical panel and making connections etc. as required (Make as per annexure enclosed).
MCCB FP 200 Amp. 36 KA Adjustable type
100 A, 30kA, FP MCCB Adjustable type
change over switch 100 amp Adjustable type
Supplying and fixing of fixtures/fittings.
Two way Gang Box
Bell Anchor Ding Dong
Ceiling Rose
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.
Exhaust fan 300 mm size
Wall fan 400 mm size
Supplying and fixing of 600 mm x 600 mm size recessed mounted LED Luminaries 36 watt. having minimum 3600 Lumens with minimum lumens efficiency 115 Lumens/watt.
Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts,on surface/recess complete with tinned copper busbar, neutral bus bar, earth bar,din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolater)
6 way ( 4+18), (Double door)
M/s Mahakaal Associates
SV ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .