Loading…
Loading…
Tender Value
₹36.1 L
EMD Value
₹72,300
Closing Date
31 Aug 2026, 5:00 pm
Harvinder Kumar
Electrical Gurugram
A/Mtc. of street light points installed 9/10/11/12 Mtr. long GI Octagonal Pole on dividing road of Sector-58-67, 69-70, SPR-I and SPR-II HSVP Gurugram.
2026_HBC_542280_1
20262347F609 ECB0 474F 86D8 1868CA8FF01F244HSV
Open Tender
Electrical Works
Works
365 days
Gurugram
2 documents required · 2 mandatory
₹1,000
₹72,300
Yes
20 Aug 2026
20 Aug 2026
1 Sept 2026
20 Aug 2026
31 Aug 2026
20 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | [24.5.2.3]MISCELLANEOUS ITEMS. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.
DWC/HDPE pipe 63/50 mm outer dia/inner dia | 370 | Mtr | 124 | ₹45,880 |
| 2 | [23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA | 30 | Nos | 4,635 | ₹1,39,050 |
| 3 | [23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA | 25 | Nos | 8,577 | ₹2,14,425 |
| 4 | [24.13.13]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK. 10 Sq mm 2 core (UnArm.) | 1,050 | Mtr | 89 | ₹93,450 |
| 5 | [24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK. 25 Sq mm 4 core (Arm.) | 1,700 | Mtr | 217 | ₹3,68,900 |
| 6 | [24.13.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK. 50 Sq mm 4 core (Arm.) | 335 | Mtr | 371 | ₹1,24,285 |
| 7 | NS) Maintenance/ repair charges of existing 11 KV HT line H-pole and 63 KVA alumn. wound transformers including all material and accessories required for repair of above mentioned 11 KV H-pole, T/F and all other equipment, and complete liaison with DHBVN complete in all respect upto the entire satisfaction of engineer in charge of work. | 144 | Nos | 735 | ₹1,05,840 |
| 8 | NS) Pdg. and laying HDPE pipe (ISI) marked of reputed make having 63mm nominal dia pipe of type PN-6-PE-63 confirming to IS:4984 standard including push fitting specials/rubber ring / couplers jointing / associated material with trenchless technology including trenching and route marker as per design the satisfaction of the engineer in charge | 150 | Mtr | 305 | ₹45,750 |
| 9 | NS) Maintenance/ repair charges of existing 11 KV HT line with , HT XLPE cable, including all material and accessories required for repair of above mentioned 11 Kv HT line all other equipment, and complete liaison with DHBVN complete in all respect upto the entire satisfaction of engineer in charge of work. Total length of HT line = (1.2 Km approx | 12 | Nos | 8,800 | ₹1,05,600 |
| 10 | NS) Mtc. / repair charges of existing 11 KV HT line with 50sqmm ACSR conductor , 50sqmm x 3 core / 95/185sqmm x 3 core HT underground cable, metering panel, 63 KVA alum. Wound T/F including GI switch and RD fuse all material accessories required for repair of above mentioned 11 KV HT line all other equipment, and complete liaison with DHBVN complete in all respect upto the entire satisfaction of engineer in charge of work Total length of HT line = 4.2 KM appx.. No. of T/F = 10 Nos | 12 | Nos | 18,250 | ₹2,19,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
BOQ_621745.xls
BOQ • 0.34 MB
OT0170804.pdf
Other Document • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].