Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 Cr+₹5.0 L (3.43%)Rejected-Finance | ₹1.5 Cr+₹5.0 L (3.43%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹1.5 Cr+₹8.2 L (5.69%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹1.5 Cr+₹8.2 L (5.69%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹1.6 Cr+₹12.1 L (8.36%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹1.6 Cr+₹12.1 L (8.36%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹1.6 Cr+₹14.0 L (9.68%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹1.6 Cr+₹14.0 L (9.68%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
6 May 2021, 5:00 pmClosed
CWE NO 2 DELHI CANTT
CWE NO 2 DELHI CANTT-10
ADL/ ALT TO POINT WIRING AND CONNECTED WKS, PREFAB SHLTRS INCLUDING MISC WORKS AT BLDG NO T-76 T-77T-14 T-86 P-113 T-16 SURGICAL I TO III MEDICAL I TO IV FOR COVID-19 WARDS UNDER PROVN OF PARA 35 AND 38 OF DWP 2020 AT BASE HOSPITAL DELHI CANTT
2021_MES_439324_1
CWE/BH-03/2021-22
Limited
Electrical and Maintenance Works
Item Rate
45 days
BASE HOSPITAL
As per Tender documents
8 documents required · 8 mandatory
₹1,000
GE E/M BASE HOSPITAL DELHI CANTT
₹2.4 L
Yes
11 May 2021
30 Apr 2021
7 May 2021
30 Apr 2021
6 May 2021
1 May 2021
Amount
S&F 5.00m X 4.00 m Pre-fabricated Portacabin cement fibre board of 50 mm thick shall be screwed on both side with attached toilet 1.20m X 1.50 m with 2.1 m wall tile of size 450X300mm complete fitting and fixture complete all as specified and directed.
1. Walls: - Wall shall be 50 mm Thick Panels fabricated with Cement Fiber Board of 6mm shall be pasted on either side of thermocole. These panels shall be joined together with GI H section to complete wall.
2. Roof: - Pre-Painted GI Sheet of 0.50 mm thickness fixed with self-tapping screws of 75mm over mild steel Hollow Pipes (25x50X4, 50x50X4)mm Section Grid. Grid size shall be 2Ft.x4Ft. covered by 6mm thick Cement Fibar board underneath. Trusses & purloins and vertical post shall be welded or fixed together with the help clamps washers as required complete. Roof is to be laid to a minimum slope of 1:20. Trusses purloins and vertical post shall be fixed together with the help of clamps washers as required complete. Ridges shall be made of 0.50mm thickness plain pre painted GI Sheet fixed with self tapping screws of 75mm. Height from floor level to bottom of truss shall be 2.40 mt and ridge to be placed according to maintain required slope. Roof shall have projection of 300 mm
3. External/Internal Painting: - External surface of walls with 3 coats of weather proof apex altima and Internal surface shall be provided with 2 coats of oil bond distemper (OBD) of Asian/ Berger.
4. Door/Window:- Door shall be provided in shed of 35 mm thick water proof flush door shutter of size 0.90mmx2.10mm with 1No. MS Sliding door bolt 250mm, 2Nos tower bolt 200mm, 2nos MS handles 150 mm long fixed with MS angle 50mmx50mmx 6mm including 3Nos. MS medium weight butt hinges 100mm welded to frame to fix flush shutter with existing structure, Aluminium Powder Coated Sliding Window in Aluminium Frame size 2.5”x1.5” slider section size 1”x.5” with plain glass of 5 mm.
5. Modular Floor: - The framework of platform shall be made of Rectangular Hollow Section of MS Steel (50x25X4mm) Confirming to grid of 600x600mm. The floor platform shall be made mainly 16mm Cement Fiber Board as per. The entire structure shall be raised above ground by 8” using steel support (Iron Joists). Superior Quality Vinyl shall be pasted on top.
6. Toilet Fixtures: - Supply and fixing of WHB size 550X400mm complete fitting, Stainless Steel IWC with cistern with connection, Looking Mirror 450X600 mm, CP Bib Tap 15 mm 3 Nos complete. Internal plumbing shall be done with CPVC Pipes. all be of Jaguar make. All plumbing and senitary fitting shall be of white vitreous china best quality.
S & F powder coated aluminium anodised section 40 x 44mm x14 gauge for aluminium partition wall in wall in panel 1m x1m covered with 5mm thick plain/frosted tinted glass on top half portion and 12mm thick pre-laminated sheet fixed in half bottom portion complete all as specfied and directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame)
S&F aluminium powder coated door frame with partially glazed shutters single/ double leaf divided into two glazed panels including aluminium anodised snap beading and rubber gasket/lining for fixing of glass as directed. The frame shall be fixed with aluminium anodised bolt by drilling in the existing wall and with thrust bolt of suitable size all as directed. The frame and shutter will be made out of the following section and fitting a) Aluminium anodised door frame 101.60 mm x 44.75 mmx2mm fixed with aluminium thrust bolt in walls by drilling as directed. b) Aluminium anodised sides rail of shutter section 83.5mmx 44.5mm x 2mm c) Aluminium anodised bottom rail of shutter section 150mm x 44.5 mm x2mm. d) Aluminium anodised top and middle rail of shutter section 100mm x 44.5 mm x 2mm. e) Aluminium anodised tower bolt 200 mm long - 02 Nos in each leaf of Make Classic/Argent as approved. f) Aluminium anodised handle 250 mm long of approved Make Classic/Argent 02. No’s in each leaf. h) Glass Pane shall be 5.5 mm thick tinted glass. j) 12mm thick prelaminated particle board laminated both side exterior grade and lock including complete all as specified and directed.
S&F 10 to 12 mm thick glass selves required size area not exc 0.5 sqm each fixed with standard bracket fittings as in wall surface complete all as specified and directed
Taking down cement plaster/grit on brick or stone wall etc including racking out joint, hacking for key, scrubbing down with water etc.complete all as specified and directed
M&L for 15mm thick rendering in cement mortar 1:4 and finished the surface even and fair w/o using extra cement complete all as specified and directed
M & L for preparing the new plaster surface of wall and applying with roller two coat of plastic emulsion interior grade paint over 3 mm thick wall care putty on walls surface complete all as specified and directed.
M&L for 75 mm PCC 1:3:6 type C-2 (40mm graded agg) as in plinth protection/hard standing and finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 7mm to 8mm thick ceramic joint free non skid tiles coloured of area exc 0.11 Sqm but nexc 0.18 Sqm (400x400mm) in flooring set and jointed in neat cement slurry and pointed in coloured cement to match with tiles laid over and including 15mm thick cement screed in cement mortar 1:4 over 25 mm thick PCC in 1:2:4 as levelling course complete all as specified and as directed.
Demolition/dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
S&F GI powder coated snap grid frame work for false ceiling (Size of grid 605X605 mm) complete all as specified and directed.
S&F 4 mm thick Eco building board fixed or laid/inserted to GI/ Aluminium framework with screws complete all as specified and directed.
S&F in repair false ceiling of PVC profile 10 mm thick of 1 mm sheet thickness, screwed over grid of panel size not exc 1200 mmX600 mm using mild steel RBS of size 50 mm X 25 mm X1.6 mm, suspended with 3 mm GI wire at a distence Not exceeding 1.20 mtr, in both direction, on dash fastener, embedded in soffit of roof complete all as specified and directed.
S&F Solid PVC Wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame acomplete all as specified and directed.
S&F of 2 Bay scrub sink made out of 16 guage thick 304 graded brushed finished stainless steel, 1.6mm thick, 1500mm length, width 565mm, height 1365mm with photoelectric sensors-2Nos, thermo static mixture valves-1 No, Solenoid valves- 2Nos with foot operated switch-2Nos spouts-2Nos for foam supply all as specified and directed.
S&F Aluminium powder coated curtain tracker with complete fitting arrangement fixing with wal, rolling wheel, hanging complete all as specified.
Supply, laying, testing and comissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty with standard aluminimum conductor 1100 Volt grade of size 3.5 Core , 185 Sqmm
Supply, laying, testing and comissioning ofcable XLPE insulated screende, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty with standard aluminimum conductor 1100 Volt grade of size 3.5 Core , 120 Sqmm
Supply, laying, testing and comissioning of cable XLPE insulated screende, PVC bedded galvanised steel strip or wire moured, electric power cable heavy duty with standard aluminimum conductor 1100 Volt grade of size 3.5 Core , 50 Sqmm
Supply, laying, testing and comissioning ofcable XLPE insulated screende, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty with standard aluminimum conductor 1100 Volt grade of size 3.5 Core , 35 Sqmm
Supply, laying, testing and comissioning of cable XLPE insulated screende, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty with standard aluminimum conductor 1100 Volt grade of size 4.0 Core , 25 Sqmm
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr deep in soft integrated rock for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance not exceeding 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
M&L point wiring suitable for modular switches with 1.5 Sqmm, single core, multi stranded copper conductor, PVC insulated and unsheathed cable (FRLS), 1100 Volts grade, drawn through and including Surface, rigid, non-metallic, 25mm dia PVC Conduit, as required at site as per IS, including terminal box, including 1.5 Sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light point controlled by one switch 5 Amps one way single pole complete all as specified and directed.
All as per item No. 30.00 above but one fan point controlled by one switch 5 Amps one way single pole.
All as per item No 30.00 here in before but for One 5 Amp socket point controlled by one switch, one way on same board complete all as specified and directed.
All as per item No 30.00 here in before but with 2.5 Sqmm copper conductor and 2.5 Sqmm Earth wire for One 20 Amp socket point controlled by one switch, one way on same board complete all as specified and directed.
S & F modular switch 1 way, 6 Amp 1 Module, single pole complete all as specified and directed.
S & F modular switch 1 way, 16 Amp 1 Module, single pole complete all as specified and directed.
S & F Modular Socket 6A - 2/3 pin 2 module, complete all as specified and directed.
S & F Modular Socket 6/16A multipurpose - 2/3 pin 2 module, complete all as specified and directed.
S & F modular cover plate with frame, 16 module complete all as specified and directed. Note- Modular switches, sockets & Cover plates with frame shall be of same make & model.
S&F rectangular surface mounted PVC Sunken block suitable for mounting, Modular switches & sockets, 16 Module complete all as specified and directed. Make : Anchor/ Precision/Prince/AKG
S & F Ceiling rose, PVC/ polycarbonate, isolated body type, three terminal, 240 Volt complete all as specified and directed.
S&F 300 mm sweep PVC exhaust fan, AC, single phase, 230/240 V, with louver, fixed as per manufacturer instruction, connecting with and including three core, 1.5 Sq mm copper conductor, PVC insulated and PVC sheathed including making suitable size hole (if required) in brick/PCC block/ Stone masonry wall built in cement mortar and making good disturbed surface complete as specified and directed.
M&L sub main wiring with 2 runs of 2.5 Sqmm single core, PVC insulated & unsheathed (FRLS) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 20 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 2.5 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 2.5 Sqmm cable and one run of 2.5 Sqmm earth conductor along with 20 mm PVC conduit with accessories shall be measured as one length)
M&L sub main wiring with 2 runs of 4.0 Sqmm single core, PVC insulated & unsheathed (FRLS) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 4.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
M&L sub main wiring with 2 runs of 6.0 Sqmm single core, PVC insulated & unsheathed (FRLS) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 6.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
M&L sub main wiring with 2 runs of 10.0 Sqmm single core, PVC insulated & unsheathed (FRLS) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 32 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 10.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 10.0 Sqmm cable and one run of 10.0 Sqmm earth conductor along with 32 mm PVC conduit with accessories shall be measured as one length)
M&L sub main wiring with four runs of 10.0 Sqmm single core, PVC insulated & unsheathed (FRLS) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 40 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 10.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Four run of 10.0 Sqmm cable and one run of 10.0 Sqmm earth conductor along with 40 mm PVC conduit with accessories shall be measured as one length)
S & F distribution board (DB), double door (CRCA sheet), dust and vermin proof SPN, 4 way, with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed.
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 8 way, with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed.
S &F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 12 way, with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed.
S & F distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN, 4 way, with 200 Amps rated copper bus bar, 415 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed.
S & F for load line distribution board double door type, TPN, vertical, 8 way, complete suitable for accomodating upto 125 Amps MCCB with incomming frame three pole , including bus bar, neutral link, blanking plates etc complete all as specified and directed.
S & F MCCB FP, 125 Amps capacity, 25 KA, DPX3 thermal magnetic, 420 Volts, complete all as specified and directed.
S & F MCB TP, 240 Volts, 63 Amps, C curve, complete all as specified and directed.
S & F MCB SPN, 240 Volts, 63 Amps, C curve, complete all as specified and directed.
S & F MCB SPN, 240 Volts, 40 Amps, C curve, complete all as specified and directed.
S & F MCB SP, 240 Volts, 10 Amps, C curve complete all as specified and directed.
S & F MCB SP, 240 Volts, 16 Amps, C curve complete all as specified and directed.
S & F MCB SP, 240 Volts, 25 Amps, C curve complete all as specified and directed.
S & F MCB SP, 240 Volts, 32 Amps, C curve complete all as specified and directed.
S & F MCB SP, 240 Volts, 40 Amps, C curve complete all as specified and directed.
S & F MCB SP, 240 Volts, 63 Amps, C curve complete all as specified and directed.
S & F MCB TPN, 415 Volts, 63 Amps, C curve complete all as specified and directed.
S&F LED Street Light fitting 45 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete.
S & F Earthing complete with galvanised GI earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below GL) with top edge of the plate not less than 1.5mtr below normal. GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I (2009) complete all as specified and directed.
S & F inverter LED batten fitting 18/20 W, 4 ft long backup time min 3 hours complete all as specified and directed.
S & F inverter LED batten fitting 9/10 W, 2 ft long backup time min 3 hours complete all as specified and directed.
Material & labour for GI steel tubing light grade for protection of cable/ earth continuty conductor fixed to poles/ walls/ roof or laid in floors, road, crossing or ducts fixed with clamps , bolts nuts and wahser etc complete all as specified and directed of pipes of size 80mm dia.
Material & labour for GI steel tubing light grade for protection of cable/ earth continuty conductor fixed to poles/ walls/ roof or laid in floors, road, crossing or ducts fixed with clamps , bolts nuts and wahser etc complete all as specified and directed of pipes of size 40mm dia.
Supply & fixing Patient Electro Medical Monitor Wall Stand for Critical care units of steel/ aluminium fabricated, movable and adjustable with optimum quality, durability for reliable operation, including fasteners, washers etc complete all as specified and directed.
Boring of hole by manual means under road/pavement/hard standing for laying of Cable/earth strip/wire etc,making good of disturbed surfaces all as specified and directed by Engr-In-Charge.
Cutting of road/hard standing for laying of LT cable/earth strip/earth wire etc, making good disturbed surfaces after laying of cable all as specified and directed by Engr-in-charge,
mahinder pal and co
The new hut furnitures
imran construction company
M/S Chhavi Constructions Co
Khairati Lal
V r traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .