Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹55.5 L
EMD Value
₹1.1 L
Closing Date
5 Feb 2020, 2:00 pmClosed
Executive Engineer Electric Division poonch
Executive Engineer Electric Division Poonch
Invitation of bids from registered A Class Electrical Contractors for Creation of1x250 KVA,7 x 100 kVA 1X63 KVA S/Stn along with HT Network forPHE WSS fall under the Jurisdiction of Sub-div Mendhar under Languishing Project of District Poonch.
2020_PDD_90733_1
e-NIT No. EDP/08 of 2019-20 Dated 20-01-2020
Open Tender
Electrical and Maintenance Works
Turn-key
90 days
Poonch
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
Executive Engineer Electric Division Poonch
₹1.1 L
Yes
17 Jul 2020
20 Jan 2020
7 Feb 2020
21 Jan 2020
5 Feb 2020
21 Jan 2020
Amount
Supply of Materials and Erection for 11 KV Lines for creation of PHE S/Stns.
Supply ,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (410, SP-33) with pit excavation, refilling the pit with soil, boulders .
Supply,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size 30 mm2 ACSR ( Weasel).
Supplying and erection of Channel “V’ cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure.
Supplying and erection of channel (75x40x6 mm) cross arms for H-frames, GI Angle( 50x50x6 mm) cross braces for H-frames, 50X50X6 mm angle support for guard netting including clamps as per REC standard.
Supply and erection of Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nutbolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard.
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1700mm for 9 mtrs Long ST Poles (410, SP-33) (the leftover pit after concreting to be filled with soil and boulders)
Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN)
Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size.
Supply ,Erection/Fixing and Testing of 11 KV Link set with GI X-arms and pin insulators.
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose.
Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection.
Supply of Material and Erection for 11/0.4 KV 1x250KVA,7X100 KVA &1X63 KVA S/stns WSS PHE Sub-Div.Mendhar.
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 250 KVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. .
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 100 KVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. .
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 63 KVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. .
Supply,Erection ,Testing and Commissioning of ST poles 9 mtr long with base plate as per IS specifications amended upto date(410 MPa-SP-33) with pit excavation.
Supply ,Installation and Testing of 11 KV G.O set
Supply ,Installation and Testing of 11 KV LA Set (Station Type)
Supply ,Installation and Testing of 11 KV HG Fuse set
Supply ,Erection/Fixing of Channel Cross arms 2.8 mtr long
Supply ,Erection/Fixing of Channel Cross arms 0.5 mtr long
Supply ,Erection/Fixing of Angle braces
Supply ,Erection/Fixing of X-arm/ Brace clamps
Supplying and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 no for neutral earthing and 25X3 mm 1 nos (for 1 transformer body earth, two no. pole earth, 1 no. LA Earth and 1 no. GO handle earth). Note: For LA Earth 1 pipe shall be kept separate
Supply and erection Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nutbolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per REC standard.
Supply ,Erection/Fixing of Aluminum Thimbles 300mm2
Supply ,Erection/Fixing of Aluminum Thimbles 185mm2
Supply ,Erection/Fixing of Aluminum Thimbles 120mm2
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole including muffing 20 cm above ground level plaster and curing of concrete in size of 600x600x1700mm for refilling the pit (the leftover pit after concreting to be filled with soil and boulders)
Supply Erection/Fixing of Angle iron for belts
Supply and painting 1 coat red oxide paint and 2 coats of al (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Supply ,Erection/Fixing of LT PVC Cable 11 KV Grade 300 mm2.
Supply ,Erection/Fixing of LT PVC Cable 11 KV Grade 185 mm2. .
Supply ,Erection/Fixing of LT PVC Cable 11 KV Grade 120 mm2 .
Supply ,Erection/Fixing of 11 kv disc insulators with fittings(45 KN).
Supply ,Erection/Fixing of pin insulators with fittings pins
Supply of Material and Erection of LT line Three Phase 4 wire on ACSR Weasel Conductor for 11 Nos S/stns WSS PHE Sub-Div.Mendhar.
Supply,Erection ,Testing and Commissioning of ST poles 8 mtr long with base plate as per IS specifications amended upto date(410 MPa-SP-15) with pit excavation.
Supply,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size 30 mm2 ACSR ( Weasel).
Supply ,Erection/Fixing of LT Mucky Clamps with GI Back Clamps without Drilling/Punching of ST Poles.
Supply ,Erection/Fixing of LT Shackle Insulators Polymer(16KN).
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole including muffing 20 cm above ground level plaster and curing of concrete in size of 600x600x1700mm for refilling the pit (the leftover pit after concreting to be filled with soil and boulders)
Supply and painting 1 coat red oxide paint and 2 coats of al (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Supply ,Erection/Fixing of LT Spacer(3phase 4wire)
Supply and fixing of Nuts and bolts of sizes for above complete works.
ms zaffar mahmood
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .