Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC 16 1 SANJAY COMPLEX PHASE NO II NEAR HAJELA HOSPITAL BHOPAL DISTT BHOPAL M P | BHOPAL | BHOPAL | MADHYA PRADESH | L1 | Accepted-AOC Work is completed release the EMD amount | |
| 2 | L2₹2.5 L+₹3,272 (1.31%)Rejected-Finance A 18 BANK NAGAR ASHOK VIHAR ASHOKA GARDEN BHOPAL 462023 | BHOPAL | BHOPAL | MADHYA PRADESH | 462023 | L2 | Rejected-Finance EMD Refund | |
| 3 | L3₹2.8 L+₹32,494 (13.0%)Rejected-Finance | L3 | Rejected-Finance EMD Refund | |
| 4 | L4₹3.0 L+₹46,390 (18.5%)Rejected-Finance G 11 PLOT NO 48 A GURUKRIPA COMPLEX ZONE II M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | L4 | Rejected-Finance EMD Refund | |
| 5 | L5₹3.0 L+₹53,289 (21.3%)Rejected-Finance 40 3 ITWARA ROAD BHOPAL | BHOPAL | BHOPAL | MADHYA PRADESH | L5 | Rejected-Finance EMD Refund |
Tender Value
Refer Docs
EMD Value
₹7,900
Closing Date
18 Mar 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Y k shrivastava
Near Mehta Parisar Nehru Nagar Bhopal Electric Section
Lighting arrangement near Kwality restaurant at New Market Bhopal
2021_UAD_133049_1
2020201641
Open Tender
Electrical Works
Percentage
15 days
Near Mehta Parisar Nehru Nagar Bhopal
as per as tender document
7 documents required · 7 mandatory
₹2,000
₹7,900
7 Dec 2023
5 Mar 2021
19 Mar 2021
5 Mar 2021
18 Mar 2021
5 Mar 2021
180 days
Amount
3000000376-Galvanized octagonal poles Providing and erecting 12.5 mt high mast lighthing system with integral power tool, weight 340 kg having two section ho hot dip galvanizied material as per BSEN ISO 1461 thick of 3 mm dia 100 top and 360 bottom respectively. the mast shall be stress fitted at site with 250 mm over dynamic loading to without maximum wind pressure as per IS 875 part III and parmeters of structures and foundation desingn should be taken form wind tunnel test. the mast shall have lighting protection of GI single spike of designated length at top. the base inside compartment with double internal locak with adequate size of MCB mounted on PVC board complete with base palte of 25 mm thick 520 mm diameter and foundation bots having 4 nos bots of 24 mm daimeter (TS 600) anchor plate 445 PCD including accessories Viz (1) Lantern carriage of 50 OD ERW calss B pipe covered with PVC sleevs suitable to carry 250 KG load and upto 6 fitting symmmetricaly (2) Traliling copper cable of 5x2.5 samm PVC insulated PVC shetehed (3) Double drum winch having gear ration 5:3:1 oil bath (SAE/90/140) arrangement to be Type tested from NIT or IIT for (4) 2 nos stainless wire ropes 6 mm diameter(7/19) oreaing load capacity 1450 kg x2 (5) integral power tool 3 phase 0.75 HP to 1 HP 2 m/min single speed (6) Feeder pillar out of 14 SWG CRCA sheet and comparaise of incoming 32 A TPN MCB single dial timer, sutiable size of contractotrs for lighting
3000004354-LED flood Lights Supply and installation of high efficiency LED street light / flood light luminaries with high pressure die cast aluminum body (make embossing on body) with toughened glass/ polycarbonate cover. The fitting should be IP66, IK-10, with power factor >0.9. The color temp of the LED should be 5000 K - 5700 K with color rendering index >70. THD less than 20%. The total system output should be not less than 110 lumens/ watt & total wattage should not be more than 300W ± 5W. The LED fitting should have L70 life of more than 50000 burning hours at 35 degree ambient temp. Surge protection should be more than 4 KV internal and 10KVexternal. The LED should have individual optic lenses and bat wing photometry suitable for street light. The LED fitting should be provided with 2 years guarantee for free repairing/maintenance or replacement of LED light fitting, LED, driver, surge protector, toughened glass / polycarbonate cover etc. on stamp paper with service center details.LM79-80 report with batch no. of supply must be supply at the time of delivery, BIS certificate is must be submitted with catalogue/model no. Spare part list of driver, cover and LED must be submitted before supply. item and Philips, Crompton, Bajaj, Havells, Wipro,C&S, Keselec Schreder, Panasonic make
Bidder Name
Amount
M T M ELECTRICALS(GSTN-23AJJPM8995L1ZC)
HEERA LAL GOUR(GSTN-23ARFPG1306F1ZK)
MAA SHARDA ELECTRICALS(GSTN-23BHVPG8485Q2Z6)
Vipin Kumar Singh Infratech Pvt. Ltd.(GSTN-23AADCV3185B1ZO)
SIDDHI VINAYAK ELECTRICAL(GSTN-23AQSPP6378G1Z8)
GOPAL DAS MISHRA - sHREE JI ELECTRICALS(GSTN-23AGGPM5882L1ZY)
JAGDAMBA FOUNDATION(GSTN-23ALQPR4323N1ZM)
JAGDAMBA FOUNDATION
MAA SHARDA ELECTRICALS
Vipin Kumar Singh Infratech Pvt. Ltd.
HEERA LAL GOUR
GOPAL DAS MISHRA - sHREE JI ELECTRICALS
M T M ELECTRICALS
M T M ELECTRICALS
MAA SHARDA ELECTRICALS
Vipin Kumar Singh Infratech Pvt. Ltd.
HEERA LAL GOUR
JAGDAMBA FOUNDATION
SIDDHI VINAYAK ELECTRICAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .