Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC | L1 | Accepted-AOC L1 Awarded | |
| 2 | L2₹14.2 L+₹1.5 L (12.0%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹15.3 L+₹2.7 L (21.1%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical CHANDIGARH CHANDIGARH CHHATTISGARH 160019 INDIA | CHANDIGARH | CHANDIGARH | 160019 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹16.6 L
EMD Value
₹33,300
Closing Date
30 Sept 2020, 3:00 pmClosed
EE PHED-2 Sirsa
EE PHED-2 Sirsa
Supplying of Bench Top-pH, Meter Make Eutech/Hech/Others, E.coli, TDS meter- Bench Top-pH meter make Eutech/ Hech/ Others, Dissolved Oxygen Meter with Optical Probe Make Hach, Digital Augo Burette at Distt. Level Lab. Sirsa
2020_HRY_145026_1
Head Office No.77894-PHE/R dated 08.09.2020
Open Tender
Chemicals/Minerals
Works
90 days
Sirsa
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
EE PHED-2 Sirsa
₹33,300
Yes
4 Dec 2020
22 Sept 2020
30 Sept 2020
22 Sept 2020
30 Sept 2020
22 Sept 2020
Amount
Non Schedule Items
pH/Conductivity/TDS Multi Parameter Meter- Make Lovibond, Hach, Thermo. • Display: Large LCD display with contrast adjustment. • Ph Range : 0-14 • Electrode Type: Plastic/gel filled electrode. • Resolution: 0.01 pH • Accuracy: ±0.02 pH • Calibration Points: 11 to 3-point calibration using pH 7 / pH 4 / pH 10 buffer solutions. Three point calibration ensures best linearity and Accuracy. • Buffer Solution: 4,7,10 Buffers solution NIST Traceable. • mV: -1999 mV to 1999 mV • Temperature Compensation for pH measurement: Automatic 0 to 65°C (32 to 149°F) with temperature probe. Manual 0 to 100°C (32 to 212°F). • Input impedance: 10 raise to power 12 ohm's. • Conductivity Range: 200 µS, 2 mS, 20 mS, 200 mS. • Measurement: 0 -200,0 µS / cm, 0.2 - 2,000 mS / cm, 2 - 20,00 mS / cm, 20 - 200,0 mS / cm. • Resolution: 0,1 µS / cm, 0,001 mS / cm, 0,01 mS / cm, 0,1 mS / cm. • Accuracy: ± (2 % F.S. + 1 digit) • TDS Range: 200 ppm, 2.000 ppm, 20.000 ppm, 200.000 ppm. • Measurement: 0 -132 ppm, 132 -1.320 ppm, 1.320 - 13.200 ppm, 13.200 - 132.000 ppm. • Accuracy: ± (2 % F.S. + 1 digit). • Resolution: 0. 1 ppm, 1 ppm, 10 ppm and100 ppm. • Temperature: 0 °C to 60 °C • Resolution: 0,1 °C • Accuracy: ± 0,8 °C • Memory functions: i) Auto shut off saves battery life; manual shut off possible by pressing "Power" button for 2 seconds. ii) Default changeable: auto power off/ manual Power off. iii) With default set at auto power off. power will off automatically after 10 minutes if no Button is pressed. • Operating Temperature: 0 to 50 °C (32 to 122°F) for the instrument (not including probes) • Operating Humidity: Less than 80% rel. humidity. • Power Supply: i) DC 1.5 V with 4 batteries (mignon size; Type AA). ii) DC 9 V by adapter input • Protection Class: IP 51 and Instrument should have Shock —absorbing protective armouring. • Internal Storage: Auto or manual data memory, 16000 data sets. • interface: USB. • Certification: Company should have ISO certification for manufacturing water testing instruments and reagents.
Mono Quartz Double Distillation Unit, 2.5 liter/hour, Make: Borosil/Duran/Infusil 230-250 V, Producing Pyrogen Free Distilled water with pH 6-7, Conductivity < 3x106 S/cm and with Auto Cut-off
D.O Meter (Dissolved Oxygen Meter) Make-Lovibond/ HACH/Thermo) • Probe: Optical DO • Protection class: IP 67 (sensor)• Display: Large LCD display. • Data Memory: Micro SD-card. • Data Logger: Software for monitoring and Strage of Data. • Software: Included in instrument. • Inerface: Micro USB.• Power off: After 10 minutes or manual off. • Power Supply: Micro USB or 4 X AA Batteries. • Salinity: 0... 50 ppt, auto compensation (with manual input salinity). • Response time: 40 sec. to 90 % of final reading. • Storage Temperature: -5 °C to 50 °C • Working Temperature: -5 °C to 50 °C • Dimensions: 162 x 98 x 54 mm (L x W x H) instrument only. • Weight: approx. 314 g (unit incl. batteries) • Languages German, English, Italian, French, Spanish, Portuguese, Dutch, Chinese (simplified). • CE-Conformity. • Measuring ranges i) Oxygen: 0 - 50 mg/I ii) Saturation: 0 - 500 % iii) Temperature: -5 to 50 °C iv) Barometer: 51 to 112 kPa • Resolution i) Oxygen: 0.01 mg/l ii) Saturation: 0.10% iii) Temperature: 0.1 °C iv) Barometer: 0.1 kPa • Accuracy i) Oxygen: 0 to 200 % or 0 - 20 mg/I: ± 1.0% of the reading or ± 0.1 mg/I whichever is greater > 200 % or > 20 mg/I: ± 10 % of reading ii) Temperature: ± 0.2 °C iii) Barometer: ± 0.2 °C • Certification: Company should have ISO certification for manufacturing water testing instruments and reagents.
Digital Auto Burette (Bottle top Burette) Make: Tarson/Axiva/Brand Cap: 10m1 Self Zero • Precision titrations within the error limits of Class A. • Large easy-grip hand wheels for sensitive, drop-wise Titration. • Titrating tube can be adjusted horizontally and vertically-providing flexibility when positioning the instrument. • No switching needed when changing between filling and titration. • Calibration scheduler saves a date for the next calibration, Auto-power-off, change decimal place setting. • Easy cleaning, maintenance and part replacement Calibration. • Calibration certificate from any NABL certified Laboratory required with validity of at least 1 year.
Hot Air Oven Make ISO Certified Company Specifications).Make : Popular/NSW/Perfit • Inner Chamber Size: (18"’x18"x18" inch (LxWxD) • inner Chamber including door made of SS304. • The Double walled chamber is filled with high grade insulation to prevent heat loss • Outer Chamber made of Stainless Steel 304 • No of shelves -2 nos. • With Digital temperature controller & air circulating fan. Elements are of the sheathed black heat type are put inside beads & placed at the bottom & in both the side ribs are placed for uniform temperature. The door closes on to an. Asbestos-gasket the shelves slide neatly into the fixed runners. • The oven is mounted on four rubber feet to prevent slipping & this protects the bench surface. The control panel houses a main On/Off switch indicator lamp & temperature controller. • Electric Supply: 220/230V AC50/60 Hz 1500watt • Temperature range adjustable from room temperature to 250 degree C
Weight Box Make : Popular/NSW/Perfit Weight Box with calibration Certificte form NABL Authorized Lab. Reading individual weight 1mg to 200gm
Bacteriological Incubator Make Popular/NSW/ Perfit Specification Capacity 220 liters • Size: - 24’’X 24" X 24"inch • Inner chamber made of steel with grade SS 304.The Double walled chamber is filled with high grade insulation to prevent heat loss. Elements are of the sheathed black heat type are put inside beads & placed at the bottom & in both the side ribs are placed for uniform temperature. The door closes on to an asbestos gasket & filled with a glass window with digital temperature controller cum indicator in lieu of thermostat & fitted fan to achieve same temperature, in each & every corner of the chamber. • Outer chamber made of mild steel. often with strong seamless welding & covered with a thick layer of stoved epoxy polyester paint, which provide a strong, highly screech & heat resistant surface for a long lasting attractive finish. • Electric Supply: 220/230V AC 50/60 Hz, 500watt Calibration Certificate from NABL Certified Lab Required. • Temperature range adjustable from room temperature to 80 degree C • Digital microprocessor based PID temperature controller with LED display
Pipette Make Eppendorf/Axiva/Tarson/Raviera Micro Pipettes : Variable volume with tip ejector and click stop 5 to 50 µL and 20 to 100 µL Calibration certificate from any NABL Certified Laboratory required
UV-Visible Spectrophotometer Pre-programmed Water analyser complete in all respect. Make-Lovibond/HACH/Thermo • Wavelength range: 190 — 1100 nm (scan range). • Optics: Mono-chromator with grating and step motor / reference beam. • Lamp: Xenon Flash Lamp (500 million flashes possible) Display: Backlit 7" color display for extensive graphical evaluation.• Operation: Membrane Keyboard (Alpha Numeric Membrane Keypad). • Stray Light: < 0.05 % Transmission at 340 and 408 nm.• Bandwidth: 4nm • Measurement: concentration, single and multi-wavelength measurement of absorbance and % transmission, kinetics, spectra. • Turbidity correction: The instrument should have automatic turbidity correction in Concentration Mode. • Scan speed: 700-2000 nm/min, Scans in 1, 2, 5, 10 nm steps of wavelength range. • Wavelength accuracy/Reproducibility: ± 1 nm / < 0.5 nm. • Photometric accuracy/Reproducibility: —0 003 E for E < 0.600: 0.5 % of values for 0.600 < E < 2.000. • Cuvette: 16 mm round, 10 mm, 20 mm, 50 mm rectangular with automatic detection w/o adapter additional 13mm and 24 mm cells could be used.• Bar code: Automatic method recognition including measurement range for all cuvettes, external bar code reader could be added. • Data storage: 5000 measurement values, spectra and kinetics approx. 40 MB => 500 spectra (300-900 nm) and 400 kinetics with 150 measurement values.• Methods and profiles: > 150 pre-programmed methods, 100 user-defined methods, comprehensive programming options, Instrument should be preprogrammed for Iron analysis at 510 nm with 1.10 Phenanthroline method as per APHA, Instrument should be preprogrammed for DO at least up to at least up to 10ppb-800ppb. Sulphate up to 1000 ppm, Manganese, Chlorine, .COD from 0 - 15000 ppm and other water analysis parameters. • Interface/update: 1 USB-A, 1 USB-B, 1 Ethernet (LIMS Connectivity ASCII, .CSV-files), External Barcode Reader and Scanner/ Update via Internet and USB stick.• IP Class: IP 30 including drainage in optical compartment. • Temperature Range: Operation: +10 °C to +35 °C, Storage: —25 °C to +65 °C. • Device Check (Validation facility of Instrument and method): Instrument should have internal Analytical quality assurance system with additional options for customising the Analytical quality assurance tools, AQA with conjunction of method and AQA for photometric determination other ingredients in sample.• Certification: Instrument must have ISO certification for production for water testing kits and instruments from manufacturer. • CE: CE Conformation as per EU guidelines. • Wavelength: Wavelength (NM) should be displayed while measurement of sample in concentration mode.• Stray light correction: at 340nm GG375 filter tolerance of T should be 0.04-0.026%. • Neutral density filter: Neutral glass F2 at 546nm should be less than ± 0.24 ABS to ± 0.003 ABS. • Built-in Security Level: Device supports the assignment of passwords and assignment of up to 3 different user levels (Guest, User, Admin). • Manual: Soft Copy of Manual Pre-programmed methods test procedure with working principle of Instrument. Do's and Don'ts during the analysis interference study and bar-coding of all the test procedures with pictorial diagram should be in the manual. • Certification: Company should have ISO certification for manufacturing water testing instruments and reagents. The supplier has to supply following ready-to-use reagents 1: - Iron 250 Tests 2: - Sulphate 250 Tests 3: - Fluoride 250 Tests 4:- Nitrates 250 Tests Cost of the above to be included in the main supply Cost will include comprehensive maintenance for 5 years from the date of commissioning.
R-INITIATIVE ENTERPRISES
RAJ KUMAR CONT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .