Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
3 Dec 2026, 2:00 pm7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer, PWD,WD-I(B),DNH,Silvassa
PWD Campus Block No.I(Bldg), DNH, Silvassa
Minor Civil and Electric Works and Supply and Installation of G.I Tower for wireless set and Installation of Parking shed at SP office complex, Sayli, Dadra Nagar Haveli.
2026_UTDNH_8349_1
E-TENDER NOTICE NO.50 OF 2026-27 (BLDG)
Open Tender
Civil Works - Buildings
Item Rate
90 days
UT OF DNH
As per NIT refer
3 documents required · 3 mandatory
₹2,000
Executive Engineer, PWD,WD-I(B),DNH,Silvassa
₹3.3 L
25 Nov 2026
25 Nov 2026
3 Dec 2026
25 Nov 2026
3 Dec 2026
25 Nov 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing & fixing LIGHT WEIGHT MASONRY BLOCKS of- Sand Based Autoclaved Aerated Concrete blocks (AAC Blocks) of any thickness using Epoxy based jointing adhesive of approved make, upto all floor level/all heights, masonry walls in jointing mortar, complete as per Technical specification, density of blocks shall not exceed 700 kg/cum, using bonding material supplied by the manufacturer as per their instructions, including necessary scaffolding for fixing, in line & level. Volumne of blocks erected to be measured for payment. R.C.C. coping of size-wall thickness x 100mm ht. at 0.91m intervals shall be provided including reinforced with 2 Numbers 6mm diameter horizontal bars and 8mm diameter at 200 c/c ties. R.C work not to be measured separately but included in rate. other specifications as directions of Engineer in Charge Complete. Procurement and installation of equipment/materials, including sourcing, supply, delivery, installation, testing and commissioning, complete in all respects | 15.62 | CUM | - | - |
| 2 | Providing and laying 10mm thick in single coat CEMENT PLASTER in (i)Cement mortar 1:3 (1-cement:3-sand) at all height/all floors to internal surfaces of all elements, walls, R.C.C. work, Ceiling,[backing coat at places where glazed or ceramic tiles are to be fixed etc]. including hacking of concrete surfaces, racking of joints, scaffolding, curing, providing chicken mesh at all necessary joints, etc. complete. Final finished surface shall be little rough , so it has proper bonding to paint putty.The surfaces to be plastered to be hacked immediately on de-shuttering. The Brick/ RCC surface to be plastered to be cured sufficiently before start of plaster. Initial bare surface area to be Plastered shall be measured for payment unless noted otherwise, etc as directions of Engineer in charge Complete. | 100.57 | SQM | - | - |
| 3 | Providing and fixing mild steel (MS) grills for doors and windows, fabricated from MS flats, square/rectangular hollow sections and/or round bars of approved size and design, including cutting, drilling, welding, grinding, fabrication, making frames, fixing lugs/holdfasts, hinges and other necessary fittings wherever required. The complete grill shall be properly cleaned, surface prepared and finished with approved quality powder coating of required colour and shade, including all necessary surface treatment, transportation, handling, installation, fixing accessories, labour, tools and tackles, complete in all respects as per approved drawings/design and as directed by the Engineer-in-Charge. | 626.4 | KG | - | - |
| 4 | Providing material & labour for Granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade. FOR URINAL PARTITIONS | 7.8 | SQM | - | - |
| 5 | Providing and Fixing Anti Skid Vitrified Floor Tiles (600×600mm, 10mm Thick) with work includes providing and fixing vitrified tiles of size 600×600 mm (2’×2’) and 10 mm thickness, of approved make, shade, pattern and finish, conforming to IS:15622 (Vitrified Ceramic Tiles). The tiles shall be non-slip/anti-skid type with textured or matt finish suitable for wet areas, utility spaces, ramps, balconies, terraces, toilets, corridors or areas exposed to spillage. The coefficient of friction shall meet slip-resistance requirements for floor use in wet areas as per standard practice. Tiles shall have water absorption less than 0.08%, uniform in colour, thickness and tone, and shall be free from cracks, bends, edge chips or surface defects. The type of finish such as double charge, nano polished, matt or anti-skid shall be as directed by the Engineer-in-Charge.
Before fixing, the existing floor or base surface shall be cleaned properly and made free from dust, grease or loose material. Any unevenness on the surface shall be corrected by applying cement mortar in proportion 1:4 (1 cement: 4 coarse sand). In case the tiles are laid over cement concrete flooring, the surface shall be well roughened and washed before laying. Tiles fixed using 20 mm average thick cement mortar 1:4 or using approved polymer-modified tile adhesive. When laying over mortar, cement slurry shall be applied on the back of the tile at the rate of 3.3 kg per sqm to ensure proper bonding. If adhesive is used, tiles shall be fixed strictly as per manufacturer’s instructions to ensure full bedding support without voids.
Tiles shall be laid in proper line and level, with joints kept uniform. After laying, tile joints shall be neatly grouted using white or coloured cement mixed with matching pigments. The surface shall be cleaned immediately after fixing to remove mortar stains, adhesive marks or grout residues. Upon completion of work, the entire flooring shall be cleaned with a soft detergent and maintained until curing is completed. Care shall be taken to avoid damage, cracking or chipping of tiles during execution.
The contractor shall provide tile samples before procurement and only the approved sample shade and batch shall be used at site. The quantity shall be measured in square metre of finished work, and the rate quoted shall include the cost of tiles, adhesive or mortar, grouting material, cutting, wastage, labour charges, curing, cleaning, loading, unloading, transportation and all other incidental works required to complete the job in all respects.
Make: Nitco, Simpolo, Kajaria, johnson, Rak or as approved by engineer-in-charge complete. | 97.9 | SQM | - | - |
| 6 | Providing and fixing vitrified tiles of size 600×600/1200x600 mm and 10 mm thick in dado, on walls, pillars or vertical surfaces, of approved make, shade, colour, pattern and finish, conforming to IS: 15622 (Vitrified Ceramic Tiles). The tiles shall be of first quality, free from cracks, edge chipping, warpage, stains, manufacturing defects and shall have water absorption less than 0.08%. Finish may be glossy, matt, nano-polished, stone finish or as directed by the Engineer-in-Charge.
The wall surface shall be cleaned thoroughly and made free from dust, efflorescence, oil or loose particles. The surface shall be prepared by applying a slurry coat of cement mixed with bonding latex or approved tile adhesive primer to ensure proper bond. Tiles shall be fixed on an even surface using polymer-modified tile adhesive of approved quality, applied as per manufacturer’s instructions to achieve full bedding without voids. The use of cement mortar for vertical tile fixing shall be avoided unless specifically permitted.Tiles shall be pressed firmly so as to achieve proper bond. Plastic spacers shall be used where recommended. After setting, tile joints shall be grouted with white or coloured cement matching tile shade. Grouting must be completed after the adhesive has fully set. Care shall be taken to avoid staining or scratching the surface. Excess grout or adhesive shall be removed using a wet sponge immediately after application. Final cleaning shall be done using mild detergent without damaging the tile surface.
The contractor shall submit samples of the tile for approval prior to purchase. Only one approved shade and batch shall be used throughout the work. Tiles shall be cut precisely using a tile cutter to fit around switches, fixtures or obstructions, ensuring clean edges. Vertical alignment, level and pattern continuity with adjacent floors or dado must be maintained.
Measurement shall be in square metre of finished work. The quoted rate shall include cost of tiles, adhesive, primer, spacers, grouting materials, cutting, labour charges, scaffolding, curing where required, cleaning, transportation, loading, unloading and all accessories necessary to complete the work.
Make: Nitco, Simpolo, Kajaria or equivelant as approved by Chief-engineer | 311.95 | SQM | - | - |
| 7 | Providing material & labour for laying Vitrified tiles 8 to 10 mm thick , in required size for Skirting upto 100mm on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry including finised with flush pointing & cleaning the surface etc. complete. For Skirting
Make: Nitco, Simpolo, Kajaria,johnson, Rak oras approved by engineer-in-charge complete. Procurement and installation of equipment/materials, including sourcing, supply, delivery, installation, testing and commissioning, complete in all respects | 13.12 | SQM | - | - |
| 8 | Providing and Fixing Granite for Platforms, Counters, Frames, Staircase and Similar Locations with work consists of providing and fixing granite in flooring, kitchen platforms, service platforms, wash basin/vanity counters, window and door frames, sills, jambs, staircase treads, risers, soffits, fascias and all similar horizontal or vertical faces. The granite shall be of approved colour, texture and thickness 18–20 mm, machine-cut, hard, sound, dense, uniform in grain and free from cracks, cavities, soft patches, veining defects, edge chipping or discoloration. The granite shall be of first quality, sourced from approved quarries and shall have straight machine-cut edges and even thickness. Polished granite shall have mirror finish, scratch-resistant surface and shall maintain uniform colour and finish across the surface. In areas where edge profiles are visible, the granite shall be homogeneous through depth, suitable for chamfering, grinding and profiling.
Granite shall be fixed with cement mortar 1:4 (1 cement : 4 coarse sand). For counters, frames and staircase work, adhesive fixing shall be preferred for full bonding. The surface to receive granite shall be cleaned, roughened where required, wetted and prepared to achieve complete adhesion. The underside of granite shall be applied with neat cement slurry or adhesive back-buttering to ensure full contact, eliminating hollows. Proper supports, clamps or props shall be provided for vertical members until the bond is set.
Joints shall be kept as thin as possible and filled with matching coloured epoxy grout or white cement mixed with approved pigment. At kitchen platforms, wet areas and wash counters, only epoxy grout shall be used. Exposed edges of granite shall be polished and finished with chamfer, half-round, full bullnose, pencil edge or profile as directed. Water drip grooves shall be provided at window sills, platform edges and external projections. All holes, openings, cut-outs, edge milling, rounding, polishing, cut-outs for sinks, wash basins, plumbing fixtures and corner shaping shall be included in the work.
The contractor shall submit samples for shade and finish approval. Only one approved shade and batch shall be used in the work. Any cracked, discoloured or damaged stone before or after fixing shall be replaced at contractor’s cost. All polishing shall be done to a mirror finish using machine polishing and oxide/approved polishing materials, ensuring a scratch-free uniform sheen.
The rate shall include cost of granite, adhesive or mortar, cement slurry, epoxy/coloured grout, polishing, cutting, edge finishing, shaping, moulding, grooving, holes and cut-outs, clamps or supports, scaffolding, cleaning, curing, transportation, loading, unloading and all incidental works. Typee:- Black, Cherry Red, Elite Brown, Cat Eye or equivalent. | 38.5 | SQM | - | - |
| 9 | Providing material and labour for making Black Granite stone Counter Wash Basin of 0.60mt wide with vertical & Horizontal Support of granite stone and having bottom slab of 25mm to 30mm thick kadappa stone fixing with cement motar 1:4 (1 Cement :4fine sand) and neat cement slurry as per requirement including cutting the granite stone & providing 7 fixing oval shape wash basin of 22''x16" size white colour in line & level. All exposed Edges of granite should be moulded including all accessories like pillar cock (Swan neck type), fexible inlet pipe 15mm dia, C.P. brass waste coupling 32mm, PVC Waste pipe 32mm etc. as directed by Enginner on Charge. | 8 | SQM | - | - |
| 10 | Providing and applying Premium exterior textured plaster finish over prepared plastered surfaces, using ready-mixed acrylic/cement-based texture coating of approved make and shade. The work shall include surface preparation, cleaning, crack filling, application of primer, textured finish (as per approved pattern such as sand, roller, stucco, or spray texture), and protective weather-resistant top coat wherever specified. The finished surface shall be uniform in texture, free from cracks, undulations, peeling, and discoloration, complete in all respects as per the architect's instructions. | 22.68 | SQM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.json
RAW_JSON
Tendernotice_1.pdf
NIT • 3.10 MB
BOQ_8541.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .