Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance NEAR MANN SINGH GURUDWARA RAJPUT PATTI BUDHLADA DISTT MANSA PB 151502 | BUDHLADA | MANSA | PUNJAB | 151502 | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 CrAdmitted-Finance PLOT NO D 25 INDUSTRIAL GROWTH CENTRE MANSA ROAD BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.2 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L3 | Admitted-Finance |
| 4 | L4₹1.3 CrAdmitted-Finance | ₹1.3 Cr | L4 | Admitted-Finance |
| 5 | L5₹1.3 CrAdmitted-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.3 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s MITTAL CONSTRUCTIONS L5 | A.V BUILDERS L4 | M/s Luxmi Constructions L6 | M/s R. Krishan and Co. L1 | M/s Azure Infrastructure Construction Co. L7 | KALRA ENTERPRISES L3 | M/S VERMA BUILDERS & DEVELOPERS L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface dressing not exceeding 15 cm deep and getting out in soft / loose soil complete all as specified and as directed by Engineer-in-Charge. | 1,240 | Sqm | 20 ₹24,800 | 26 ₹32,240 | 36 ₹44,640 | 20 ₹24,800 | 30 ₹37,200 | 15 ₹18,600 | 15 ₹18,600 |
| 2.00 | Removing excavated material (soil ) exc. 1.50 km but not exceeding 5 km and depositing where directed complete all as specified and as directed by Engineer -in-charge. | 24 | Cum | 150 ₹3,600 | 550 ₹13,200 | 720 ₹17,280 | 100 ₹2,400 | 900 ₹21,600 | 300 ₹7,200 | 650 ₹15,600 |
| 3.00 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for foundation etc or for shafts , wells, cesspits, manholes , septic tank, for laying of cables , laying of pipes not exceeding 10 Sqm on plan and not exc 1.5 meter depth and getting out in soft/loose soil etc complete all as specified and as directed by Engineer-in- charge. | 579.8 | Cum | 150 ₹86,970 | 120 ₹69,576 | 144 ₹83,491.20 | 70 ₹40,586 | 100 ₹57,980 | 120 ₹69,576 | 100 ₹57,980 |
| 4.00 | Material and labour for Cement Concrete 1:4:8 , Type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge. | 78.4 | Cum | 3,800 ₹3.0 L | 3,100 ₹2.4 L | 3,600 ₹2.8 L | 2,000 ₹1.6 L | 2,000 ₹1.6 L | 2,600 ₹2.0 L | 3,100 ₹2.4 L |
| 5.00 | Material and labour for RCC M-25 (Design mix) using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. | 56 | Cum | 7,500 ₹4.2 L | 5,300 ₹3.0 L | 6,660 ₹3.7 L | 6,500 ₹3.6 L | 4,000 ₹2.2 L | 5,500 ₹3.1 L | 5,600 ₹3.1 L |
| 6.00 | Material and labour for RCC M-25 (Design mix) using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. | 44 | Cum | 7,500 ₹3.3 L | 5,600 ₹2.5 L | 7,200 ₹3.2 L | 6,500 ₹2.9 L | 8,000 ₹3.5 L | 6,700 ₹2.9 L | 6,200 ₹2.7 L |
| 7.00 | Material and labour for RCC M-25 (Design mix) using 20 mm graded stone aggregates as in beams, cantilevers, bressummers, lintels over 1.5 m span and the like etc complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. | 27.6 | Cum | 7,500 ₹2.1 L | 6,100 ₹1.7 L | 7,380 ₹2.0 L | 6,500 ₹1.8 L | 8,000 ₹2.2 L | 6,700 ₹1.8 L | 6,200 ₹1.7 L |
| 8.00 | Material and labour for RCC M-25 (Design mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-charge.
NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. | 75.7 | Cum | 7,500 ₹5.7 L | 6,500 ₹4.9 L | 7,380 ₹5.6 L | 6,500 ₹4.9 L | 8,000 ₹6.1 L | 6,700 ₹5.1 L | 6,200 ₹4.7 L |
| 9.00 | Material and labour for RCC M-25 (Design mix) using 20mm graded stone aggregate as in Chajjas complete all as specified and as directed by Engineer-in-charge.
NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. | 16.24 | Cum | 7,500 ₹1.2 L | 6,500 ₹1.1 L | 7,380 ₹1.2 L | 6,500 ₹1.1 L | 8,000 ₹1.3 L | 6,700 ₹1.1 L | 6,200 ₹1.0 L |
| 10.00 | Material and Labour for Formwork of sides of concrete foundations, Footings, Bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge. | 294 | Sqm | 550 ₹1.6 L | 230 ₹67,620 | 297 ₹87,318 | 250 ₹73,500 | 300 ₹88,200 | 225 ₹66,150 | 350 ₹1.0 L |
Updated dates
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
21 Feb 2026, 6:00 pmClosed
CWE Bathinda
HQ CWE Bathinda Bathinda Mil Stn
PROVN OF CONSTRUCTION OF FOUR GUARD ROOMS ALONG WITH TOILETS CUM BATHROOMS , REPAIR BAY, 2 X INSPECTION PITS, TOOLS AND MT STORES, PAINT STORE AND FOL STORE COVERED UNDER VARIOUS LBW WORKS UNDER GE ( NORTH) BATHINDA AT BATHINDA MIL. STN.
2025_MES_726658_2
CWE BTD/TOKEN-19/2025-26
Open Tender
Civil Works
300 days
Bathinda Mil Stn
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (N) Bathinda
₹1.9 L
HQ CWE Bathinda
2 Apr 2026
27 Jan 2026
23 Feb 2026
27 Jan 2026
21 Feb 2026
14 Feb 2026
6 Feb 2026
Surface dressing not exceeding 15 cm deep and getting out in soft / loose soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material (soil ) exc. 1.50 km but not exceeding 5 km and depositing where directed complete all as specified and as directed by Engineer -in-charge.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for foundation etc or for shafts , wells, cesspits, manholes , septic tank, for laying of cables , laying of pipes not exceeding 10 Sqm on plan and not exc 1.5 meter depth and getting out in soft/loose soil etc complete all as specified and as directed by Engineer-in- charge.
Material and labour for Cement Concrete 1:4:8 , Type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for RCC M-25 (Design mix) using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for RCC M-25 (Design mix) using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for RCC M-25 (Design mix) using 20 mm graded stone aggregates as in beams, cantilevers, bressummers, lintels over 1.5 m span and the like etc complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for RCC M-25 (Design mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for RCC M-25 (Design mix) using 20mm graded stone aggregate as in Chajjas complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and Labour for Formwork of sides of concrete foundations, Footings, Bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
Material and Labour for Formwork in square,reactangular or polygonal on rough finished surface of concrete to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed by Engineer-in-charge.
Material and labour for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. on rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for Formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) on rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
Material and Labour for Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete rail ings, openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20cm wide on rough finished surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia including making of rungs, handles etc complete all as specified and as directed by Engineer-in-charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 6mm to 8mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia including making of rungs, handles etc complete all as specified and as directed by Engineer-in-charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips directed by Engineer-in-charge.(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for Brick work with fly ash old size bricks straight or curved on plan exceeding 6.0m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in-charge.
Material and labour for Brick work with fly ash old size bricks, straight or curved on plan to any radius in half brick walls built in Cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge.
Removing excavated material as in all kind of Soils not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by Engineer-in- charge.
Returning filling in any type of soil, including spreading, levelling,watering and well ramming in layer not exceeding 25 cm in each layer, complete all as specified and as directed by Engineer-in- charge.
Material and Labour for Sand filling under floor or in foundation including spreading levelling, watering and well ramming in layers not exc 25 cmetc complete all as specified and as directed by Engineer-in- charge. Note: Sand shall be approved by GE.
Material and Labour for Hard core using broken stone aggregate of gauge not exc. 63mm, deposited spread and leveled in layers not exc. 150 mm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in- charge.
Material and labour for 100 mm thick cement concrete 1:4:8 , type D-2 using 40 mm graded stone aggregate as in sub base of floor. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and labour for 75 mm thick cement concrete 1:4:8 , type D-2 using 40 mm graded stone aggregate as in sub base of floor. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and Labour for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces of walls and finishing the surface even & fair faces without using extra cement complete all as specified and as directed by Engineer-in- charge.
Material and labour for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and labour for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finishing fair & even mixed with Liquid water proofing compound as per manufacturer's instructions but without using extra cement complete all as specified and as directed by Engineer-in-charge. Note :- Liquid water proofing compound shall be measured and paid separately.
Supply only Liquid water proofing compound complete all as specified & as directed by Engineer-in-Charge.
Material and labour for rendering 5 mm thick in cement mortar in 1:3 on ceiling/ Chajja and finishing the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and Labour for applying acrylic wall care putty on internal surfaces and external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and leveling of surfaces in two or more layers) by using ready made acrylic wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed by Engineer-in- Charge. Make of acrylic wall care Putty : AS descriped in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. (ii)The make of acrylic wall care putty shall be as per the recommendation of manufacturer of paint.
Material and Labour for Preparation of surfaces and applying 02 coats of Interior Acrylic Emulsion Paint (light shade as approved by GE ) @ 10.00 Sq.m/ litre / 2.00 coats by using roller/brush to wall surfaces over with and including one coat of Interior Acrylic Emulsion Primer @ 10.00 Sq.m / litre / 1.00 coat as recommended for under coat by manufacturer of Interior Acrylic Emulsion by using the brands of Interior Acrylic Emulsion Paint and Interior Acrylic Emulsion Primer as descriped in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after complete all as specified and directed by Engineer-in- Charge.
Material and Labour for Preparation of surfaces and applying 02 coats of Exterior Acrylic Emulsion Paint ( shade as approved by GE) with highlighter of any approved shade, @ 5.00 Sq.m / litre / 2.00 coats by using roller to External walls / RCC surfaces / Soffits of Chajjas / Roof projections / Cantilevers / Balcony etc. surfaces over with and including one coat of Exterior Acrylic Emulsion Primer @ 11.00 Sq.m / litre / 1.00 coat as recommended for under coat by manufacturer of Exterior Acrylic Emulsion by using the brands of Exterior Acrylic Emulsion Paint and Exterior Acrylic Emulsion Primer as descriped in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after complete all as specified and directed by Engineer-in- Charge.
Material and Labour for for preparing new plastered surfaces of ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and directed by Engineer-in- Charge.
Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat of Size 45mm x 70 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply and Fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges complete all as specified and as directed by Engineer-in- charge.
Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat with double rebate of Size 65mm x 125 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply and Fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges complete all as specified and as directed by Engineer-in- charge.
Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) SS 150mm long Tower Bolt, Supply & Fixing of 02 Nos (per door) SS 300mm long Sliding Bolt with and including Supply & Fixing of 02 Nos (per Leaf) Stainless Steel 150mm long handle complete all specified and directed by Engineer -in-charge.
Supply & Fixing Factory Made 30mm thick Solid WPC ( Wood polymer Composite ) Wiremesh Door Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension rade ), calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cum , having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter for fixing Mosquito mesh and XTN aluminium mesh together on panel area of door except stiles and rails to be panelled with and including mesh with self tapping round headed scresws at required distance, screws and edges covered with feathered pvc edge beading all around of mesh and fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws with and including 03 Nos door Stainless steel butt hings 100mm long with Stainlessd steel screws for each , 02 Nos stainless steel barrel tower bolts of extrude section, 150mm long (ISI marked), 2 Nos stainles steel handles, 125 mm long, (ISI marked) , 01 No. of helical door spring of 300 mm length complete all as specified and as directed by Engineer-in-charge. Note: 1. Material test certificate of all the items and authentication should be compulsory provided by the manufacturing company 2. The rate of 03 Nos door Stainless steel butt hings 100mm long with Stainlessd steel screws for each , 02 Nos stainless steel barrel tower bolts of extrude section, 150mm long (ISI marked), 2 Nos stainles steel handles, 125 mm long, (ISI marked) , 01no. of helical door spring of 300 mm length is inclusive in this item and nothing shall be paid extra on this item..3. The rate of Mosquito mesh and XTN aluminium mesh is included in this item and nothing shall be paid extra on this account.
Supply and fixing of factory made uPVC white colour Three track Slider Window including glass & mesh of area exceeding 1.00 Sqm and not exceeding 2.00 sqm each window made of extruded profiles of high impact modified grade manufactured from Tropicalized Blend with TiO2 and required additives, colorfast & being able to withsatand a weather resistance test of 16000 hrs on weathering apparatus, resistant to chemicals, and be fungal and vermin proof. The uPVC profile should be classed as self extinguishing to prevent support or enchancement of accidental fires. Extruded profile duly reiniforced with minimum 120 gsm zinc coated GI of 1.5mm to 2.5mm thickness to meet the wind load requirement on sash/mulilion and fitted in continuous length in closed chamber of required length (shape and size according to uPVC profile design). The internal drainage shall be isolated from chambers into which reinforcement can be placed or through which frame fixing passes. Drainage shall be either through the base or alternatively to the face, concealed by face drainage caps. uPVC systems must be fabricated with fusion welded corners and uPVC extruded glazing beads of appropriate dimensions with EPDM/TPE Gaskets. All hardware fitted must be of stainless steel, multipoint espag, plastic packers, plastic caps & necessary stainless steel screws, except handles to be of Zinc/Al alloy casted with powder coated, GI fasteners 100mm x 8mm size for fixing frame to wall. Outer frame of windows 118mm x 50mm , sash 45mm x 60mm consisting of multi chambered frame, sash 7 mullion/transom (wherever required), The sizes of the sections indicated are minimum and no additional cost shall be claimed for use of higher sections due to design considerations. The wall thickness of the profile shall be minimum 2.0 ± 0.2mm. The sheet glass shall be toughened of thickness 5mm. The wire mesh shall be of stainless steel stainless 0.36mm nominal dia of wire and average width of aperature 1.40 mm. After fixing the frame the gap between the frame and adjacent finished wall shall apply Silicon sealant to make joint, water proof of approved quality. There would be a conditional warranty of minimum 10 years on profile & 02 years on hardware from the date of completion. The uPVC system must be installed by profile manufacturer or their authorised agents only complete all as specified and as directed by Engineer-in- charge. (Note :- The rate of 5mm thick toughened glass for glazing and stainless steel wire mesh cloth 0.36mm nominal dia of wire and average width of aperature 1.40 mm is included in this item and nothing shall be paid extra on this account. Net opening will be measured for payment purpose.)
Supply and fixing of factory made uPVC white colour Louvered Casement Window of area not exceeding 1.00 Sqm each window made of extruded profiles of high impact modified grade manufactured from Tropicalized Blend with TiO2 and required additives, colorfast & being able to withsatand a weather resistance test of 16000 hrs on weathering apparatus, resistant to chemicals, and be fungal and vermin proof. The uPVC profile should be classed as self extinguishing to prevent support or enchancement of accidental fires. Extruded profile duly reiniforced with minimum 120 gsm zinc coated GI of 1.5m to 2.5mm thickness to meet the wind load requirement on sash/mulilion and fitted in continuous length in closed chamber of required length (shape and size according to uPVC profile design). The internal drainage shall be isolated from chambers into which reinforcement can be placed or through which frame fixing passes. Drainage shall be either through the base or alternatively to the face, concealed by face drainage caps. uPVC systems must be fabricated with fusion welded corners and uPVC extruded glazing beads of appropriate dimensions with EPDM/TPE Gaskets. All hardware fitted must be of stainless steel, multipoint espag, plastic packers, plastic caps & necessary stainless steel screws, except handles to be of Zinc/Al alloy casted with powder coated, GI fasteners 100mm x 8mm size for fixing frame to wall. Outer frame of windows 45mm x 50mm , with fixed frosted glass in the lower half, 4mm thk glass pinhead louvers in the upper half and Mesh consisting of multi chambered frame, sash & mullion/transom (wherever required), The sizes of the sections indicated are minimum and no additional cost shall be claimed for use of higher sections due to design considerations. The profile of the frame shall be suitable to install and fix mild steel guard bars. The wall thickness of theprofile shall be minimum 1.8 to 2.3 ± 0.2mm. The sheet glass shall be toughened of thickness 5mm. The wire mesh shall be of stainless steel stainless 0.36mm nominal dia of wire and average width of aperature 1.40 mm. After fixing the frame the gap between the frame and adjacent finished wall shall apply Silicon sealant to make joint, water proof of approved quality. There would be a conditional warranty of minimum 10 years on profile & 02 years on hardware from the date of completion. The uPVC system must be installed by profile manufacturer or their authorised agents only complete all as specified and as directed by Engineer-in- charge. (Note :- The rate of 5mm thick toughened glass for glazing, 4mm thick pinhead glass and stainless steel wire mesh cloth 0.36mm nominal dia of wire and average width of aperature 1.40 mm is included in this item and nothing shall be paid extra on this account. Net opening will be measured for payment purpose.)
Material and Labour for 75 mm thick PCC 1:3:6 , Type C-1 using 20 mm graded stone aggregate as in plinth protection, finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in- charge.
Supply only chain link mild steel galvanised fencing (mesh size 100 mm x 100 mm of 10 gauge wire) complete all as specified and as directed by Engineer-in-charge. .Note : The weight of chain link fencing shall be ascertained by BOO as ordered by GE and payment shall be made accordingly. BOO duly counter signed by GE shall be enclosed with final bill.
Supply & Fixing sheet glass 5.00 mm thick tinted quality and glazing complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Mild steel Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4mm and fixed with tinned tacks to stainless steel wire staple complete all as specified and as directed by Engineer-in-charge.
Material and Labour for anti-skid premium (1st) quality coloured ceramic tiles 400 X 400 mm and 7-8 mm thick,, in floors etc with and including 10 mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured epoxy grout to match the shade of tile including necessary cutting as per site requirement complete all as specified and as directed by Engineer-in-charge.
Material and Labour for providing and laying Premium (1st quality) straight edge,Stain free, glooss finish, Square marbonite Double charged vitrified tiles size in 600mm x 600mm x 9mm to 10mm thick as in floors etc. shade as approved by GE , set and jointed with using spacer and approved High polymer modified, grey cement-based tile adhesive suitable for fixing medium format tile/stone in walls/floor conforms to IS 15477 : 2019 type 2T “Adhesives for use with Ceramic, Mosaic and stone Tiles” Conforms to EN 12004: 2017 and is a normal cementitious adhesives (C1) with slip resistance (T) of class C1 and necessary grouting as per manufacturer’s instruction, completed all as specified and directed by engineer-in-charge.
Material and Labour for providing and laying Premium (1st quality) straight edge,Stain free, glooss finish, Square Double charge vitrified tiles size in 600mm x 600mm x 9mm to 10mm thick as in skirting surfaces shade as approved by GE , set and jointed with using spacer and approved High polymer modified, grey cement-based tile adhesive suitable for fixing medium format tile/stone in walls/floor conforms to IS 15477 : 2019 type 2T “Adhesives for use with Ceramic, Mosaic and stone Tiles” Conforms to EN 12004: 2017 and is a normal cementitious adhesives (C1) with slip resistance (T) of class C1 and necessary grouting as per manufacturer’s instruction, completed all as specified and directed by engineer-in-charge.
Material and Labour for glazed ceramic coloured tiles 7.5 mm to 8.5mm thick 450mm x 300mm size in verticle surface with and including 10mm thick backing coat using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement etc complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing 16 mm bore CPVC pipe SDR 11 with and including CPVC SDR 11 fittings and fixed to walls & ceilings or laid in floors, complete complete all as specified and as directed by Engineer-in-charge
Supply and Fixing 20 mm bore CPVC pipe SDR 11 with and including CPVC SDR 11 fittings and fixed to walls & ceilings or laid in floors, complete complete all as specified and as directed by Engineer-in-charge
Material and labour for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 etc complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing 15mm bore, brass Chromium Plated single liver central hole basin mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Brass Chromium Plated wall mixer for mixing hot & cold water screwed down, screwed for 15mm bore pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 15mm bore bib tap, long body, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 15mm bore Stop valves, fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
Supply and fixing Angular Stop Cock with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete all as specified & directed by Engineer-in-charge.
Supply and fixing 32/40mm size waste fittings, brass, CP, for glazed ware sinks, basins etc. with long flange end embedded in red lead cement and other end fixedcomplete all as specified & directed by Engineer-in-charge.
Material and Labour for Oval type vitreous china Wash Hand Basin, white, Size of 550mm x 460mm ,with and including 32mm chromium plated waste coupling and PVC bottle trap and fixing in marble slab complete all as specified and approved by GE / directed by Engr-in-Charge. Note: marble slab shall be measured and paid separately.
Material and Labour for vitreous china wash down water closet pan wall hanging single piece (with and including flushing cistern EWC) 'P' trap, with and including white coloured closed pattern plastic seat cover, hand faucet , with and including mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer-in- charge.
Material and Labour for Concealed in wall PVC flushing cistern of 10 Litre capacity with dual flushing system, valveless syphonic action type, with and including inlet/outlet, ball valve, float and with and including brackets and connection to pipe etc., with and including all necessary accessories,installation kit and 'S' type drain pipe connetion set for wall hung WC etc. as recommended by manufacturer for fixing, packing , with and including actuator knobs,flush plates complete all as per manufacturer's instructions in all respect complete all as specified and as directed by Engineer-in-charge.
Supply & fixing chromium plated square shower rose 200mm x 200mm size, with or without swivel joints, any size, including fixing to steel pipe or union for 15mm bore of pipe complete all as specified and as directed by Engineer-in-charge.
Supply & fixing PVC connections 15mm size with brass nuts of length 450mm complete all as specified and as directed by Engineer-in-charge.
Supply & fixing PVC waste pipe with socket suitable for connection to Waste fittings of 32/40mm dia, and of length minimum 75 cm complete all as specified and as directed by Engineer-in-charge.
Supply & fixing Rotational Moulded Polyethylene water storage tank ISI Marked of capacity 1000 litres (cylindrical vertical, with closed top), hoisted and fixed in position including making inlet and out let connection complete all as specified and as directed by Engineer-in-charge. (Note :- Ball valve and gate valve shall be measured & paid separately under appropriate items of Schedule 'A' BoQ.)
Supply and Fixing Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge.
Supply & fixing stainless steel AISI-304 cock roach trap gratings of size 150mm x 150mm square in shape with 5mm border complete in all respect all as specified.
Supply and fixing sheet glass shelf assembly consisting of 5.5 to 6mm thick glass shelf 12 cm wide and 450mm long with bevelled edges/hatching of edges fixed with stainless steel 'D' bracket fixed and railing complete all as specified.
Supply and fixing sheet glass shelf assembly of 300mm x 300mm for corners consisting of 5.5 to 6mm thick glass shelf and with bevelled edges/hatching of edges fixed with stainless steel 'D' bracket fixed and railing complete all as specified.
Supply and fixing peg set / coat hooks (set of six hooks) made of stainless steel complete all as specified and as directed by Engineer-in- charge. .
Supply and fixing chromium plated brass towel rail, 20mm dia, D type, 60cm long fixed to wall complete all as specified and as directed by Engineer-in- charge.
Material and Labour for Vitreous China Urinal, Half stall type, white, including connections to flushing pipe and outgoing pipes , including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating, with and including CP urinal spreader , with and including 32mm bore PVC waste pipe complete all as specified and directed by Engineer-in- charge.
Material and labour for Green Marble as approved by GE , 20mm thick machine cut, (table rubbed and polished) for counter sunk wash basin, plateform /cooking plateform , steps, jambs,pillars, window cills, , shelves, urinal partition and like , with and including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of marble slabd complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing 110 mm bore of pipe PVC (SWR) type B ring fit pipes single socket in any length fixed with clamps as shown in BTD Drg No. 916 sheet 1/4 to 4/4 and BTD-917 sheet sheet 1/1 of stays to wall at a distance of 100-120mm away from walls complete all as specified and as directed by Engineer-in- charge
Supply & fixing 75 mm bore of pipe PVC (SWR) type B ring fit pipes single socket in any length fixed with clamps as shown in BTD Drg No. 916 sheet 1/4 to 4/4 and BTD-917 sheet sheet 1/1 of stays to wall at a distance of 100-120mm away from walls complete all as specified and as directed by Engineer-in- charge
Material & Labour for 75 mm dia PVC (SWR) floor trap type B , plain with grating including jointing with solvent complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Water proofing tratment to roof / terrace (material of water proof treatment as approved by GE) Single component, acrylic based, flexible, micro fibre reinforced waterproofing and heat reflective coating system. the treatment shall be carried out as per the manufacturers instructions and shall include the followings: (a) Preparation of substrate and cleaning it off all loose and triable by mechanical means (b) Open the cracks lines to form , V grooves with cutter/hammer/chisel up to 5-10mm and filling with crack filler and PU sealant. (c) application of primer coat @ 0.2 to 0.3 kg/ sqm followed by the first coat @ 0.75kg/ Sqm. (d) The second coat shall be applied @ 0.75 kg / Sqm and reinforced with fabric re-inforcement between the first and second coat. (e) The top coat of primer shall be applied after the second coat dries off @ 0.05-0.08 Kg per Sqm. (f) The material shall adhere to following specification. TECHNICAL SPECIFICATION OF MATERIAL Tensile Strength 1.5 MPa ASTM D412 Elongation at Break > 200% ASTM D412 Adhesion in Peel > 1.5 MPa (on concrete substrate) EN 1542 Crack Bridging Ability Passes upto 3.2mm Width ASTM C1305 Permeability to Water Vapour Passes IS 2645 Water Vapour Transimission ~ 23 g/m²/24hr ASTM E96 Water Absorption < 10% ( by Mass) ASTM D570 Microbiological Resistance No Algae & Fungal Growth ASTM D5590 Solar Reflectance Index 102 ASTM E1980. Note : Complete material shall be approved by GE and procured in bulk and kept in lock and key. Note : The installation company should be trained and authorized by Manufacturer & installation to be carried out as per manufacturers approved method statement. All auxiliary & accessories involved during application should be supplied by single manufacturer as a part of system. Any component used which is not manufactured by the particular manufacturer can only be used with official approval from manufacturer in consultation with GE.
Material and Labour for 40mm average thick PCC padding in 1:2:4 Type B-1 (using 20mm graded stone aggregates) as in roof slab finishing the surface even and fair using Liquid water proofing compound complete all as specified and directed. Liquid Water proofing compound shall be measured and paid separetly as supply only under appropriate item of Schedule 'A' BoQ.
Material and labour for cement slurry @ 1.2 kg /sqm spreading with bristle brush with and including rendering 15 mm (average thickness) in cement mortar 1:3 finished even and fair mixing with Liquid water proof compound 200ml per 50 kg cement bag on roof surface complete all as specified and as directed by Engineer-in-Charge. Note:- Liquid water proofing comound shall be measured and paid seperately as supply only in appropriate item of schedule 'A' BoQ.
Material and Labour for Making benching with PCC 1:2:4 type- B0, using 12.5mm graded stone aggregates using with Liquid Water Proof compound as per manufacturer's instruction along side wall adjoining to roof in concave shape complete all as specified and directed. Note : Liquid Water proofing compound shall be measured and paid separetly as supply only under appropriate item of Schedule 'A' BoQ.
Material and labour for 10 users 2000 ltrs capacity PVC moulded Anaerobic Septic Tank for an anaerobic design in which bacteria treats waste under most favourable conditions, process effectively prevents rapid accumulation of sludge and suspended solids from passing through the system untreated with innovative engineering design of the inlet- outlet short circuit of waste water which is prevented to ensure long and enough retention time for effective treatment, thus the effluent dose not contain any solid or scum that could clog up the pipe line.The septic tank is buried underground, solid and liquid waste flow into it. Heavy solid waste settle to the bottom of the septic tank (known as sludge). The liquid wastes are also held in the septic tank while bacteria break down solids into liquids in an anaerobic environment, process is known as primary treatment certain bacterias and viruses are adsorbed into solid particles and held in the sludge or scum layers, allowing for limited removal of disease causing organisms at the stage. All that has to be done for fitting the tank is to fill the tank with water, connect the drain line to the inlet and outlet to the soak pit. Cover the manholes with the lids provided and tank is ready to use including 150mm thick PCC 1:4:8 Type B-1, using 20mm graded stone aggregates below foundation and vent shaft connection, including excavation, returning and filling, removal of excess soil, connection to existing sewage line including site clearance etc.complete all as specified and directed by Engineer-in- charge.
Supply , fixing and Testing PVC Manhole of Polyethylene Material (PE) , Manhole Base of size 800 mm dia with and including 3 Nos. inlet and 3 Nos. outlet of required size complete all as per manufacturer's instructions and complete all as specified and directed by Engineer-in-charge.
Excavation over areas , not exceeding 1.5 mtr deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in charge.
Exacavation of areas, exceeding 1.5 mtr and not exceeding 3.0 mtr deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in charge.
Exacavation of areas ,exceeding 3.0 mtr and not exceeding 4.5 mtr deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in charge.
Material and Labour for Hard core using broken bricks of gauge not exc. 63mm, deposited spread and leveled in layers not exc. 150 mm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in- charge.
Material and Labour for loose filling with broken bricks of gauge 80 to 150mm in sokage pits, sokage wells complete all as specified and directed by Engineer-in charge.
Supply & Fixing Mild Steel Rungs of 20mm dia bar all as specified and directed by Engineer-in-charge
Supply and Fixing and testing 100mm bore Sand Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors Complete all as specified and as directed by Engr-In-Charge.Note: Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.
Supply and Fixing and testing 100mm bore Sand Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls Complete all as specified and as directed by Engr-In-Charge.
Material and labour for PCC (1:3:6) type C-2 using 40 mm graded stone aggregates as in concrete bed for DWCPE pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested including form work complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm.(iii) Excavation , earth work , returning filling shall be measured and paid seperately under appropriate items of schedule 'A' BoQ.
Supply , Fixing and testing for providing ,lowering , laying DWCPE (SN 8) pipe of 150mm internal bore as per IS-16098 of 2013, laid in trench and jointed with and including elastomeric sealing 'O' ring and fittings complete all as per manufacturer's instructions , complete all as speified and as directed by Engineer-in-charge. Note:- Excavation , earth work, returning filling , removal ,bedding and pedestal / anchorage if required shall be measured and paid separately under appropriate item of BOQ/ Sch 'A'
Material and labour for Damp proof course 40 mm thick cement concrete (1:1.5:3) type B-0, using graded stone aggregate mixed with water proofing compound as per manufacturer’s instructions , over with and including applying one coat of cold applied bituminous primer @ 0.70 litre per sq. m, over with and including blown bitumen grade 85/25 @ 1.20 kg/Sq. m surfaces including necessary formwork complete all as specified and as directed by Engineer-in-charge. Note : Ther rate of blown bitumen grade 85/25 @ 1.20 kg/Sq. m ,bituminous primer @ 0.70 litre per sq. m is included in this item and nothing shall be paid extra on this account.
Material and labour for RCC M-25 (Design mix) using 20 mm graded stone aggregates as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttressese measured and paid for separately under appropriate item of this schedule.
Material and labour for Formwork to faces of walls, retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter on rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for 15mm thick rendering in CM (1:6) (internal surface) on other than fair faces of brick work or concrete surfaces and finishing even & smooth but without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and Labour rendering 10 mm thick on concrete surface in concrete surfaces in cement mortar 1:3 complete all as specified and directed by Engineer-in-Charge.
Material and Labour for 15 mm thick rendering in CM 1:3 mixing with WPC @ 200 ml per bag of cement on fair faces of concrete surfaces on roof slab after wire brushing and cleaning top surface complete all as specified and as directed.(WPC shall be measured separately)
Material and Labour for morrum/red bajri filling in floors or pavings, laid in layers not .exceeding 15cm thick, spread,levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
Material and labour for cement concrete flooring 25 mm thick levelling course PCC 1:2:4 type B-1 using 20mm graded aggregate finished even and rough to receive tiles complete all as specified and directed by Engineer-in-Charge.
Material and labour for machine cut kota stone slab 20-25mm thick as in flooring, laid over with and including 15mm thick cement screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
Material and labour for machine cut kota stone slab 20-25 mm thick as in vertical surfaces such as skirting/ Dado etc. laid over with and including 10mm thick cement rendering in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
Material and Labour for factory made,machine pressed precast interlocking paver block 60 mm thick with grey cement and no pigment, any shape and size, conforming to IS 15658-2006, made out of M-35 grade concrete laid over and including 25 mm thick layer of sand cushioning complete all as specified and as directed by Engineer-in- charge. Note: The rate of 25mm thick layer of sand cushioning is included in this item and nothing shall be paid extra on this account.
Material and Labour for factory made,machine pressed precast interlocking paver block 60 mm thick with grey cement and pigment, any shape and size, conforming to IS 15658-2006, made out of M-35 grade concrete cushioning complete all as specified and as directed by Engineer-in- charge.
Material and Labour for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engineer-in- charge.
Material and Labour for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed by Engineer-in- charge.
Material and Labour for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Pressed steel frames for doors with one or more rebates with and including lock strike plate, fixing lugs, etc., size of frame 105mm x 60mm,with and including one shop coat of zinc chromate primer complete all as specified and as directed by Engineer-in-charge. (thickness of steel sheet shall be 1.25mm) Note:- 1.. The rate of one shop coat of zinc chromate primer is included in this item and nothing shall be paid extra on this account.
Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard wood with lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply and Fixing 35mm thick, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), using 2nd class hard wood (Bonsum/ Hollock) edges of frming plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc , sizes of members of shutters as specified in SSR Part-I, Section8, Clause 8.24 (a), supplied and fitted to chowkhats complete all as specified and as directed by Engineer-in-Charge. Note:- Wire gauze/ glass shall be measured and paid separately.Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply and fixing 100mm long powder coated mild steel butt hinges medium weight cold rolled complete all as specified & directed by Engineer-in-charge.
Supply and fixing anodised aluminium handle cast type 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing aluminium anodised sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge.
Supply & Fixing for steel window box type double shutter ( glazed with wire gauge)with side hung shutters including hinges with steel handle and steel peg stay complete with glazing bar dovetailed or welded and including window guard bar, tower bolt,flat iron for fixing wire netting with and including one shop coat of zinc chromate primer paint and making good to distrubed portion match with existing surfaces complete all as specified and directed by Engr-in-Charge.
Material and labour for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or lesscomplete all as specified and direcgted by Engr -in-Charge
Material & Labour for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft / Loose soil complete all as specified and directed by Engineer-in- Charge. complete all as specified and directed by Engr-in-Charge.
Material & Labour for cement concrete type C-1 (1:3:6) (using 20mm graded aggregate) as in post holes, foundations, filling and mass concrete, side kerb, haunching , coping , and like, in filling back of Pressed steel chowkats/frame and in bed blocks to hold fast complete all as specified and directed by Engr-in-Charge.
Supply & Fixing mild steel work as in tubular (round/square/ rectangular shape of pipes as approved by Engr-In-Charge) trusses, purlins, rafter, MS plates,connecting plates, up to height 7mtr including post special shaped washers etc complete incl necessary nut bolts, wind ties and gusset plates etc using ERW or induction butt welded tubes conformining to IS 1161-1979 grade St-240 complete all as specified and directed by Engr-in-Charge.
Supply & Fixing Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including cutting to shape as directed, drilling holes, for nut & bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410 -W (Gde E- 250) quality A complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing 5-10 mm dia , exceeding 5cm and not exceeding 10cm long MS screw bolt machine made with hexagonal or square head at one end and screwed the other,or screwed both ends,each screwed end fixed with washer complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for Pre -Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm Thickness of any colour having aTensile strength of 550 MPA as in roof covering fixed with 'L' type or 'J' type or cranked hook bolts all as specified and directed by Engineer-in-Charge.
Supply and fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
Material and Labour for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over with and including one coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-charge.
Material and Labour for precast cement concrete 1:1/2:3 type A1 (Using 20mm graded stone aggregate) as in cover slabs set in cement mortar (1:4) complete as specified and directed by Engineer-in charge.
Material and Labour for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete as specified and directed by Engineer-in charge.
Material and Labour for Concealed point wiring for modular type fittings using approved colour coding as per IS (Red, Black and Green for single phase circuits), with two single core 2.5 Sqmm PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked, drawn through with and including new PVC rigid conduit 20mm dia ( heavy duty ) ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all new fittings and all accessories i.e pipe bend pipe hook, elbow,junction box,with and including one single core 2.5 Sqmm PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade (ISI Marked) (as in green colour) as continuous earth continuity conductor including modular metal flush box concealed with front & modular cover plate with frame suitable matching colour of required module for mounting or housing modular switches 5Amp /6 Amp ,modular socket outlets 5Amp /6 Amp,modular fan regulators, modular two way switches 5Amp /6 Amp and modular bell push 5Amp /6 Amp for bell/ buzzer with and including blanking plates & all other fixing accessories for one light/ fan point controlled by one way 5/6 Amps modular switch complete all as specified and as directed by Engineer-in- charge Notes for serial item nos.129.00, 130.00 & 131.00 : (i)The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates and flush fixed with cement mortar 1:4 etc.However modular switches 5Amp /6 Amp, modular socket out let5Amp /6 Amp , modular fan regulators modular two way switches 5Amp /6 Amp and modular bell push 5Amp /6 Amp for bell/ buzzer shall be measured and paid seperately under respective items of Schedule'A' BoQ. (ii) The rate of cutting chases (as required) is included in this item and nothing shall be paid extra on this account. (iii) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clips as directed by Engineer-in- Charge.The rate of this element is included in this item and nothing shall be paid extra on this account
All as per serial item No 129.00 of BoQ here-in-before but for modular socket outlet 5 pin 5/6 Amp on same board, complete all as specified and directed by Engineer-in-charge.
All as per serial item No 129.00 of BoQ here-in-before but for modular socket outlet 5 pin 5/6 Amp on independent board but not below the switch board, complete all as specified and directed by Engineer-in-charge.
Material and Labour for Concealed point wiring for modular type fittings using approved colour coding as per IS (Red, Black and Green for single phase circuits), with 4.0 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked, drawn through with and including new PVC rigid conduit 25mm dia ( heavy duty ) ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all new fittings and all accessories i.e pipe bend pipe hook, elbow,junction box,with and including one single core 4.0 Sqmm PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade (ISI Marked) (as in green colour) as continuous earth continuity conductor (green in colour) including modular metal flush box concealed with front & modular cover plate with frame suitable matching colour of required module for mounting or housing modular switches 15Amp/ 16 Amp and modular socket outlets 15Amp/16Amp, for modular socket out let point 15Amp/16Amp controlled by one way 15Amp/16 Amp modular switch with and including blanking plates & all other fixing accessories and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge Notes for serial item no.132.00 : (i)The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates and flush fixed with cement mortar 1:4 etc.However modular switches 15Amp/16Amp and modular sockets 15Amp/16Amp shall be measured and paid seperately under respective items of Schedule'A' BoQ. (ii) The rate of cutting chases (as required) is included in this item and nothing shall be paid extra on this account. (iii) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clips as directed by Engineer-in- Charge.The rate of this element is included in this item and nothing shall be paid extra on this account
Supply and fixing sheet metal enclousers made out of CRCA mild steel sheet , IP-54 protection, flush mounted with metal door, powder coated DB SPN 12 way 230 V AC with 200 Amp rated copper bus bar, Double Door,08 modules, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items. (ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account.
Supply and fixing sheet metal enclousers made out of CRCA mild steel sheet , IP-54 protection, flush mounted with metal door, powder coated DB SPN 8 way 230 V AC with 200 Amp rated copper bus bar, Double Door,08 modules, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items. (ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account.
Supply and fixing MCB SP 6 to 32 Amps, 230 volts , AC supply , rupturing capacity not less than 10KA,' C' Curve ,ISI Marked, complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB 32 Amp SPN ,240Volt , rupturing capacity 10 KA , CURVE ‘C’ ISI Marked, complete all as specified and directed by Engineer-in-charge.
Supply and fixing Modular Switch one way , 6Amp ,1 module, 250 volts ,AC supply, ISI marked , complete all as specified and directed by Engineer-in-charge
Supply and fixing Modular Socket outlet , 6 Amp-2/3 pin combined 2 module , 250 volts ,AC supply, ISI marked complete all as specified and directed by Engineer-in-charge.
Supply and fixing Modular Switch one way 16 Amp,1 module 250 volts , AC supply , ISI marked complete all as specified and directed by Engineer-in-charge.
Supply and fixing Modular Socket outlet 6Amp/16Amp-2/3 pin combined,2 module ,250 volts ,AC supply, ISI marked complete all as specified and directed by Engineer-in-charge.
Supply and fixing ceiling rose 3 terminal flush type 6 Amp 250V ,ISI marked ,AC supply, topline series with polycarbonate 20mm x 50 mm two to three terminal, complete all as specified and directed by Engineer-in-charge.
Supply and fixing Lamp holder ,ISI marked of PVC/Polycarbonate type with back plate suitable for batten fitting with and including 9Watt LED retrofit Lamp (base B-22) complete all as specified and directed by Engineer-in-charge.
Supply and fixing New generaton energy saving, wall mounted LED Tube light batten fittings, extruded aluminium heat sink provided for efficient heat dissipation and intergrated electronic drive 20 Watt LED duly fitted on PVC Square block ,6500K, 4.00 feet long with and incuding LED Rod 20 Wat ,230 volt,50Hzs complete all as per manufacturer's instructions including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector complete all as specified and as directed by Engineer-in-Charge. Notes: (a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including lamps from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include to fix LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. (d) The rate of electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector is included in this item and nothing shall be paid extra on this account.
Supply & Fixing Building Security LED Light of 25 watt , IP 66 , luminaire with high power with toughened glass complete as per manufacturer's instructions with and including bracket made out with 40mm bore Galvanised Iron Light grade pipe 1.20 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt ,nuts and washers complete and fixing to wall / column with and including electrical connection with 1.5 mtr long twin core round copper conductor cable of suitable size and testing complete all as specified and directed by Engineer-in-charge. Notes: (a) The rate of bracket made out with 40mm bore Galvanised Iron Light grade pipe 1.20 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts and electrical connection with 1.5 mtr long twin core round copper conductor cable of suitable size is included in this item and nothing shall be paid extra on this account. (b) Contractor has to furnish a replacement warranty of 02 years for Security LED Light fittings complete including lamps from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All Security LED Light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include to fix Security LED Light fittings walls/building which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account.
Supply and fixing Energy saving IP-66 Flood Light luminaire with high power COB LED flood light fitting sqaure shape 70 Watt , 5000K,230V ,AC supply, with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp, bracket with impact and corrossion resistant complete with suitable bolt and nuts complete all as per manufacturer's instructions including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector complete all as specified and as directed by Engineer-in-Charge. Notes: (a) Contractor has to furnish a replacement warranty of 02 years for LED flood Light fittings complete including lamps from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED flood light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include to fix LED flood Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. (d) The rate of electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector is included in this item and nothing shall be paid extra on this account.
Supply and Fixing Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, IP-54 protection, flush mounted for metal door, powder coated DB VTPN 4 way, 415 V AC with 200 Amps rated copper bus bar, Double door, dust and vermin proof suitable for incorporation of Incoming MCCB and outgoing MCBs / MCCBs/ Isolators and earth & neutral bus bar and using copper lugs pin/ Ring type for cable connection conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and as directed by Engineer-in- charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items. (ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account.
Supply and fixing MCCB 63 Amp, 4 Pole, 415 volt, ISI Marked,short circuit breaking capacity not less than 25KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc .complete all as specified and directed by Engineer-in-charge.
Material and Labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 3.5 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 4 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 2 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 10 Sqmm 2 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Material and Labour for Making holes for 300 mm dia exhaust fan of suitable shape & size into or through brick walls complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Exhaust fan 300mm sweep (Heavy duty) steel body, BEE, 5 star rated ,AC Supply, single phase ,230 volts, 50HZ,900RPM with and including frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc. mounted in suitable opening arrangmement in wall and electric connection with and including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC Conduit and hanging on wall with 04 Nos. steel fastners 10mm dia 100mm long with and including serial number of fan as issued by Engineer-in-charge and GE office name with red colour permaent marker complete all as specified and directed by Engineer-in-charge.
Supply & Fixing Ceiling fan of 1200mm sweep complete with blades, down rods, with and including remote control, single phase, 50 Hz, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current (BLDC) motor connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of suitable size from ceiling rose / connector, including extra GI / MS pipe down rod, as per site requirement , with and including serial number of fan as issued by Engineer-in-charge and GE office name with red colour permaent marker complete all as specified and directed by Engineer-in-Charge.
Supply, install, testing and commissioning of water cooler fully stainless steel body, 5 star rating, electric driven single phase having storage capacity 40 ltrs and nominal cooling capacity 40 ltrs per hour complete as per manufacturer's instructions and as directed by Engineer - in - charge.
Supply , install , testing and commissioining Evaporative air cooler in steel body(Desert cooler) with propeller cooler fan made out of hot deep galavinized steel thickness 1 mm body and 2 mm removable sides and back panels single phase 230 volts of fan size 450 mm sweep with submersible pump of suitable size (maximum power consumption 250 watts) ISI marked 5 star rating , BEE approved having normal air flow capacity 6000 cum per hr , with and including 15mm bore Ball brass valves,high pressure, with polythene float and fly nut, with and including 15mm bore Stop valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends ,nuts,washers, with and including PVC connections of 15mm bore , leakage proof joints and all the necessary arrangmemnts to take water from GI Pipe medium grade 15mm bore to air cooler. Note:- (i) Sufficient length as required at site of 3 core PVC sheathed round cooper cable of size 23/076mm to enable fixing into plug point shall be provided by the contractor at his own cost . The rate of this aspect is included in this item and nothing shall extra be paid on this account.(ii) The rates of 15mm bore Ball brass valves,high pressure, with polythene float and fly nut, 15mm bore Stop valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends, nuts,washers, PVC connection of 15mm bore, leakage proof jonts etc and making connection from GI Pipe medium grade 15mm bore to air cooler are included in this item and nothing shall extra be paid on this account. (iii) The rate of arrangement for power connection and water connection to the desert cooler is included in this item and nothing shall extra be paid on this account.
Supply and Fixing water heater (Geyser) Auto restrat and safety measures type electrical operated 230/240 Volts 25 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, plug top, etc. required for proper functionality & including electric/earth connections and carrying out grounting & complete installations with mounting bolts,nuts including testing after installation complete complete all as specified & directed by Engineer-in- Charge.
Material and Labour for 4 Nos. rawl plug of suitable size (4"-6") with nuts & bolts and grouting in RCC / Brick wall, cutting of exisiting GI pipe line of size 15 mm dia in position for insertion of tee , elbow, niple, union, reducer, branch connection ,etc. with necessary GI fittngs i.e. Tee, elbow, niple, union ,reducer, branch connection etc. and plumbing work and connection jointing and making good as per existing surfaces complete all as specified and directed by Engineer-in-Charge .Note : The rate of 4 Nos. rawl plug of suitable size (4"-6") with nuts & bolts ,Tee, elbow, niple,union, reducer, branch connection etc. of galvanised iron is included in this item and nothing shall be paid extra on this account.
Supply and fixing Single Pole and Neutral enclosure with a two pin and earth plug and socket complete with and including one MCB single pole of capacity 25 Amps,'C' curve,10KA , 240 volts complete all as specified and directed by Engineer-in-Charge.Note: The rate of one MCB single pole of capacity 25 Amps,'C' curve, 10KA, 240 volts is included in this item and nothing shall be paid extra on this account.
Supply & fixing Steel water tubing 15 mm bore medium grade, galvanised, ISI Marked including all tube fittings with screwed and socketed joints fixed to walls, ceiling or under floors etc complete complete all as specified & directed by Engineer-in- Charge.
Supply and Fixing Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed for iron pipe of bore 15 mm ISI Marked complete all as specified and directed,all as specified & as directed by Engineer-in-charge.
Supply & fixing PVC connection 15mm size with PTMT nuts 450 mm long ,(Hot series braded, threaded and cold series)complete all as specified & directed by Engineer-in-charge.
Supply and fixing 15mm bore Bib tap , cast copper alloy, , with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
Material and Labour for Cutting of exisiting GI pipe line of size 20 mm / 25mm dia in position for insertion of tee , elbow, niple, union, reducer, branch connection ,etc. with necessary GI fittngs i.e. Tee, elbow, niple, union ,reducer, branch connection etc. and plumbing work complete all as specified and directed by Engineer-in-Charge .Note : The rate of Tee, elbow, niple,union, reducer, branch connection etc. of galvanised iron is included in this item and nothing shall be paid extra on this account.
Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose)
Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing GI tubing, light grade 40 mm bore complete with all fittings for cable protection, fixed along poles or laid under floor , under road and hardstanding etc. complete with flat iron clamps of size 25mm x 4 mm , nuts, bolts and washers complete and making good after laying of cable complete all as specified and as directed by Engr - in- Charge.
Material and Labour for Making the hole under road and hard standing suitable for laying and inserting pipe up to 100mm dia pipe of any length by mechanical drill system or Auger system and making the surface good as per existing surface complete all as specified and all as directed by Engineer-in-charge. Note : The rate of pipe is not included in this item and Pipe of suitable size shall be measured and paid seprately under relevant item of Schedule 'A' BoQ.
Supplying and laying un-reinforced precast concrete cable cover, class LV ,type 1 , flat, size 250 mm x 150mm x 40mm complete all as specified and directed by Engineer-in-charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
technical_840009.pdf
techsummary_840009.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 4.35 MB
8119Tender.pdf
Tender Documents • 2.24 MB
BOQ_840009.xls
BOQ • 0.45 MB
8119TenderDrgs.pdf
Additional Documents • 19.10 MB
8119NIT.pdf
Additional Documents • 4.33 MB
Download all tender documents and submit your bid