Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC 223 3 SWAMI VIVEKANANDA ROAD RAMKRISHANA PALLY TAKI ROAD BARASAT KOL 700124 | BARASAT | NORTH 24 PARGANAS | WEST BENGAL | 700124 | L1 | Accepted-AOC L 1 | |
| 2 | L2₹5.4 L+₹13,480 (2.54%)Rejected-Finance | L2 | Rejected-Finance L 2 | |
| 3 | L 3₹6.0 L+₹70,589.62 (13.3%)Rejected-Finance 1 TARPAN GHAT ROAD KOLKATA KOLKATA WEST BENGAL 700053 | KOLKATA | WEST BENGAL | 700053 | L 3 | Rejected-Finance L 3 | |
| 4 | L 4₹9.2 L+₹3.9 L (72.8%)Rejected-Finance | L 4 | Rejected-Finance L4 |
Tender Value
₹6.4 L
EMD Value
₹12,741
Closing Date
10 Jun 2025, 5:30 pmClosed
Member Secretary
West Bengal Pollution Control Board, Paribesh Bhawan, 10A, LA Block, Sector III, Bidhannagar, Kolkata 700106 III, Bidhannagar, Kolkata 700106
Supply, installation, testing, and commissioning of fire detectors along with fire alarm and public address system and fire extinguisher in Durgapur Regional Office-cum-Lab complex of West Bengal Pollution Control Board
2025_PCB_851743_1
WBPCB/OM-RO(DGP)/2025 (e-06)
Open Tender
FIRE FIGHTING M/R
Item Rate
45 days
Sahid Khudiram Sarani, City Centre, Burdwan-713 21
As stated in the bid documents
3 documents required · 3 mandatory
₹1,000
₹12,741
West Bengal Pollution Control Board, Paribesh Bhaw
1 Aug 2025
26 May 2025
11 Jun 2025
26 May 2025
10 Jun 2025
29 May 2025
28 May 2025
Amount
Laying and Jointing PVC Pipe. Heading
SITC of Microprocessor base Conventional Repeater Panel Fire Alarm Control Panel with Location entry facility for ,RS 485 repeater communication ,Repeater Panel can monitor the status of the main Panel,LCD Display along with , Battery Charger and all accessories. ( Make: Ravel/SystemSensor /Eaton)
SITC of Response Indicator, with all other required accessories ( Make: System Sensor/Apollo /Eaton/equivalent)
Supplying m fitting & fixing ISI Marked Dry Powder type Fire Extinguisher 25Kg. Capacity conforming to ISI:16018:2018 fitted withGun Metal cap ,high pressure discharge hose with nozzle, mounted on trolly wheels complete with initial refill consisting of Co2 cylinder of 1kg . capacity with ISI Marked controlled valve conforming to IS:3224 and ISI Marked Sodium base dry chemical power conforming to IS:4308, suitablefor operating between -30° C to + 55°C, Fire Rating Class -233B (Make -Mini Max / Cease Fire /Fire Shield or Similar Brand)
Supplying, fitting and fixing pressure type Fire Extinguishers ISI Marked, suitable for Class 13B fire 4.5 kg. capacity Co2 Type consisting of cylinder, squeeze lever discharge valve fitted , internal discharge tube,discharge nozzle suspension brackt, conforming to IS:15683:2006 duly charges, suitable for operating between -30 degree C to +55 degree C,Fire Rating Class -13B.Supply fittings & Fixing fire Extinguisher steel stand dimension (L x W x H ) 27cm X 27 X 35cm ) for existing all portable fire Extinguishers & all other charges (Brand -Mini Max / Cease Fire /Fire Shield or Similar Brand)
Supplying, fitting and fixing pressure type Fire Extinguishers ISI Marked, suitable for Class 3A & 34B fire 9 Ltrs. capacity FOAM consisting of welded cylinder, squeeze lever discharge valve fitted with pressure including gauge, internal discharge tube, discharge nozzle suspension bracket, conforming to IS:15683:2006 duly charged with Nitrogen Gas, suitable for operating between -30 degree C to +55 degree C, Fire Rating Class -3a & 34B.Supply fittings & Fixing fire Extinguisher steel stand dimension (L x W x H ) 27cm X 27 X 35cm for all existing portable fire Extinguishers & all other charges (Make -Mini Max / Cease Fire /Fire Shield or Similar Brand)
Supplying, fitting and fixing pressure type Fire Extinguishers ISI Marked, suitable for Class 2A & 21B fire 6 kg. capacity ABC type consisting of wielded cylinder, squeeze lever discharge valve fitted with pressure including gauge, internal discharge tube,discharge nozzle suspension brackt, conforming to IS:15683:2006 duly charges with ISI Marked Momo ammonium phosphate base ABC Powder conforming to IS:14609 and pressurized with Nitrogen Gas, suitable for operating between -30 degree C to +55 degree C,Fire Rating Class -2A & 21B with Supply fittings & Fixing fire Extinguisher steel stand dimension (L x W x H ) 27cm X 27 X 35cm ) for existing all portable fire Extinguishers & all other charge. (Make -Mini Max / Cease Fire /Fire Shield or Similar Brand)
SITC of Public Address system integrated Fire Alarm Control Panel with main consoles, Expanders, amplifires Ahuja 250 Wattage & including all accessories Panel can monitor the status all accessories. ( Make: Ravel/SystemSensor /Eaton Agni)
Supplying, fitting & fixing WALL/CEILING MOUNTED SPEAKER complete with all accessories as per direction of the Engineer-in-Charge. (Make : Ahuja/Bose/JBL)
SITC of Microprocessor base 12 Zone Conventional Main Fire Alarm Control Panel complies with UL-864 & NFPA -72 ,20 X 4 Dot Matrix LCD Display,1000 Event storage with RTC,peer to peer network facility maxumum 16 panel can be connect in a single Network,TCP/IP modul &PC software (optional),MODBUS for BMS intergration (Optional) along with Battery, Battery Charger and all accessories. ( Make: Ravel/SystemSensor /Eaton)
SITC of conventional type photothermal Multicriteria detector,LPCB Approved with mounting based and all other required accessories ( Make: System Sensor/Apollo/ Ravel /Eaton)
SITC of Manual call Point Operates on 24DC ,One Number C& N C Output, with all accessories . ( Make: System Sensor/Apollo/Eaton )
SITC of Hooter cum sounder on 24VDC 100DB@1 meter. with all accessories. (Make: System Sensor/Apollo/Eaton )
Supply & drawing of 2 x 1.5 sq. mm multi-core copper FRLS wire & Shielded cable conforms to IS 694:1990 and also have FIA/TAC approval., Shielded cable fix on the conceal/surface. (Make: Finnolex /Havells/RR)
Supply, and fixing of FRLS conduits in 20mm sizes including cost of junction boxes,bends,elbows sockets, tees etc. (Make Precision medium/AKG/Finolex )
Signage: Providing and installing in position the following type AUTOGLO Photoluminescent Signages complete with fasteners Signage with printed "EXIT"ALL TYPES (Size: 150mm x 200mm)
Providing and fixing in position the signage "FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut ,PVC non-reflective self-adhesive vinyl painted foam board of 3' x 4' A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATINGMANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POINTS. C) IF POSSIBLE ONE TRY TO EXTINGUISH THE FIRE BY USING NEAREST /SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC,WALK,DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. (However final matter to be printed as per approval and instruction from the Engineer-in-Charge)
Supply & Fixing in position the signage’s “Floor Drawing with your position” on 3mm thick ”Opaque” PVC foam board of computerized cut, FIRE ESCAPE PLAN PVC non-reflective self adhesive vinyl painted foam board of size 1200 x 1000mm
Floor identification signage AUTOGLO (i.e., 1/2/3....etc) Size 225mm x 225mm at each stair enclosure on every floor & Room
Supply & Fixing in position the signage’s “Floor marking night glow Luminous self Adhesive safety fire escape with your position “as FIRE ESCAPE PLAN
Preparation of detailed plan with interior layout of all floors (G+2) in AutoCAD format after visiting Site as per Our Fire evacuation plan and civil renovation work. Submit hard copy and soft copy.
B.S.A ENGINEERING (BID ID -6535020)
CHANDRANI COMPLIMENTS AND EXPORT PVT. LTD. (BID ID -6502436)
SAFETY ENTERPRISE (BID ID -6522852)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .