Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC 30 8 ANDUL 1ST BYE ZONE HOWRAH 711109 | HOWRAH | HOWRAH | WEST BENGAL | 711109 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹34.9 L+₹1.7 L (5.14%)Rejected-Finance MASAT HARIPUR RD VILL P O HARIPUR HOOGHLY | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L2 | Rejected-Finance Bid is Not L1 | |
| 3 | L3₹35.6 L+₹2.3 L (7.01%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L3 | Rejected-Finance Bid is Not L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
11 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Office of the Executive Engineer PWD Howrah Electr
Office of the Executive Engineer PWD Howrah Electrical Division Onkarmal Jetia Road Howrah 711103
Repair and Renovation of Electrical work of entire Hospital building of Hazi S.T. Mullick R.H. Howrah. RN. 19002040. Project ID HF192020493S000.
2021_WBPWD_331336_1
WBPWD/EE/HED/NIQ-32(2nd Call) of 2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
240 days
Hazi S.T. Mullick R.H. Howrah.
Please refer Tender documents.
9 documents required · 9 mandatory
₹70,000
Office of the Executive Engineer PWD Howrah Electr
29 Nov 2021
13 May 2021
14 Jun 2021
14 May 2021
11 Jun 2021
26 May 2021
25 May 2021
365 days
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/ Polycab / KEI) for ECC in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall for horizontal & vertical runs and in suitable size PVC casing-capping (Precision make) for ceiling portion only, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment flushed in wall incl. mending good damages to original finish [only PVC casing-capping on ceiling and remaining portion concealed] 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
6 Mtr. [ 8 (b) / E- 23 ]
8 Mtr. [ 8 (c) / E- 23 ]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (FINOLEX/POLYCAB/KEI) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish.(Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure )
On Board [ 3 (i) / E- 20 ]
Average run 4.5 mtr [ 3 (iv) / E- 20 ]
Average run 7.5 mtr [ 3 (vi) / E- 20 ]
SUB-HEAD 2-- PLUGS & SOCKETS
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 13/E-18 ]
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. [ 12/E-18 ]
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ), without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 nos. 6 A, 3 pin Modular type plug socket with 2 nos. 6A Modular type switch (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ), without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 16/E-19 ]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 2 Module [ 2-a/E-17 ]
Supply & Fixing 240 V 6 A Modular type switch (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ) on existing GI Modular type switch board having top cover plate and making necessary connections as required. [ 3-a/E-17 ]
Supply & Fixing 240 V Modular type Indicator lamp (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ) on existing GI Modular type switch board having top cover plate and making necessary connections as required.
Supply & Fixing 240 V 16 A Modular type switch (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ) on GI Modular type switch board having top cover plate and making necessary connections as required. [ 3-b/E-17 ]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 4-c/E-17 ]
Supply & Fixing 240 V, 25A Modular starter (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 20/E-19 ]
Supply & Fixing Modular type RJ45 sitable for CAT6 cable (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ) on existing PVC board and top cover plate on wall and making necessary connections as required. [ 7-a/E-18 ]
Supply & Fixing Telephone socket (RJ11) Modular type (Legrand - Myrius/ Arteor, L&T- Entice/Englaze / Schneider- Unica pure ) on existing GI Modular board having top cover plate and making necessary connections as required. [ 7-b/E-18 ]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchor) on sheet metal switch board surface on wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [ 22/E-6 ]
Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. [Legrand make] [ 18/D-12 ]
SUB HEAD 3 - LAYING PIPES AND DRAWING WIRES
Cutting Channel of size (31 mm x 31 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles .
13 mm dia 3 mm thick [ 5(a)/ E- 2 ]
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles . 19 mm dia 3 mm thick [ 6(a)/ E- 3 ]
Supplying & Fixing two way CI Round box with cover concealed in ceiling/wall. [20(b)/ E- 6 ]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works .
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene/G.I. pipe as per GS.[ Finolex/Polycab/ KEI]
2x(2.5 sqmm)+1x(1.5 sqmm)[ for 16 A Power plug, Computer Board ] [ 1(s) / E-9 ]
2x(4 sqmm)+1x (2.5 sqmm)[ For RAC & 3nos 16A plug board ] [ 1(v) / E- 9]
2x (6 sqmm) + 1x (4 sqmm) [ 1 (y) / E- 9 ]
2x(10 sqmm)+1x(6 sqmm) [ 1(b1) /E- 9 ]
2x126/0.4 (16 sqmm) + 1x80/0.4 (10 sqmm) as ECC. [ 1(e1) /E- 9 ]
4x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC. [ 1(x) /E- 9 ]
4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC [ 1(a1) /E- 9 ]
4x(10 sqmm)+2x(6 sqmm) [ For 3P, 40 A Outlet ] [ 1(d1) /E- 9 ]
4x(16 sqmm)+2x(10 sqmm) [ For 3P, 63 A Outlet ] [ 1(g1) /E- 9 ]
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2.5sqmm [9(i)/F-5]
4 sqmm [9(ii)/F-5]
6 sqmm [9(iii)/F-5]
10sqmm [9(iv)/F-5]
16sqmm [9(v)/F-5]
SUB-HEAD 4--BDB,PDB,VTPN ETC
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Legrand/ABB/SCHNEIDER]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Legrand/ABB/SCHNEIDER]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment . [Legrand/ABB/SCHNEIDER]
4Way ( Up to 160 A ) [15 / D- 11]
8Way ( Up to 160 A ) [15 / D- 11]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. [16 / D- 12 ]
4 Way HTPN
6 Way HTPN
4 Way VTPN
8 Way VTPN
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS. [Legrand/ABB/SCHNEIDER]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Legrand/ABB/SCHNEIDER]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs /enclosure and necessary connection. [Legrand/ABB/SCHNEIDER]
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating on Angle iron frame.(Make-L&T) [4(a)/D-3 ] 125A TPN SFU
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting. [5/D-5 ] 63/125A
SUB-HEAD 5-- SUPPLY & LAYING OF CABLES
Supply & Laying of cable 4 core 16 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.[2.b/F-1] [Mk. Gloster/Havells/Polycab].
Supply & Laying of cable 4core 35 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting [2.c/F-1]. [Mk. Gloster/Havells/Polycab].
Supply & Laying of cable 4 core 70 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. [2.d/F-1] . [Mk. Gloster/Havells/Polycab].
S & Laying of one No. cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. [Mk. Gloster/Havells/Polycab].
4 Core 16 sqmm [ 1(a)/F-2 ]
4 Core 35 sqmm [ 1(a)/F-2 ]
4 Core 70sqmm [ 1(b)/F-2 ]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : [F4/7c]
4 core 16 Sq.mm
4 Core 35 Sq. mm
4 Core 70 Sq. mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : F5/8b.
4 core 16 Sq.mm
4 Core 35 Sq. mm
4 Core 70 Sq. mm
Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. [21/E-19]
Supplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. [22/E-19]
SUB-HEAD 6 - SUPPLY & FIXING OF LIGHT FITTINGS
Supply & Fixing of 30 watt (2'x2') LED full Glow High eficiency light fittings ( Make-Philips, Cat. No.RC380B LED30S-6500 G4 L60W60 PSU OD OC/ Crompton/ wipro having similar specification ) on false ceiling after cutting the false ceiling incl. necessary connection and mending goods the damages to original finish.
Supply & Fixing of Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 1xT-LED22W P3241/ Crompton/wipro having similar specification). incl S&D 1x 18/20 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I/ Crompton/ wipro having similar specification ) suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/ socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. [ 15/C-2 ]
Supply & Fixing of Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 1xT-LED22W P3241/ Crompton/wipro having similar specification). incl S&D 1x 18/20 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I/ Crompton/ wipro having similar specification ) with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. [ 14(b)/C-2 ]
Supply & Fixing of Twin industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 2xT-LED22W P3241/ Crompton/wipro having similar specification). incl S&D 2x 18/20 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I/ Crompton /wipro having similar specification) suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/ socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. [ 15/C-2 ]
Supply & Fixing of Twin industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 2xT-LED22W P3241/ Crompton/wipro having similar specification). incl S&D 2x 18/20 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I/ Crompton /wipro having similar specification) complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. [ 14(b)/C-2 ]
Supply & Fixing of 12W recess mounted LED down light ( Make-Philips, DN193B LED12S-4000 PSU WH S2/ Crompton/ wipro having similar specification ) on false ceiling after cutting the false ceiling incl. necessary connection and mending goods the damages to original finish.
Supply & Fixing of 240V 9W LED SC lamp (Min 900lumen) [ make Philips Ace Saver/ Wipro / Crompton] on existing batten point.[11/C-2 ]
Supply & Fixing of LED Bulk Head fittings ( Make-Philips, Cat. No.WT202WLED6S NW PSU S2PC / Crompton/ wipro having similar specification ) on wall /ceiling by screws etc.[13/C-2 ]
Supply & Fixing of surface mounted 18/20 W LED round ceiling fittings ( Make- Crompton LCRP-20-CDL Model: Royal Rimless-R / Philips / wipro having similar specification ) on wall incl. necessary connection and mending goods the damages to original finish as per direction of EIC.
Fixing only Recessed type circular (Dia up to 8 inch) LED down light after cutting the false ceiling incl. necessary connection as required
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [16/C-2 ]
SUB-HEAD 7 -- SUPPLY & FIXING OF FANS
Supply & Fixing of 48"ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. 48″ sweep, 230V 1-Ph. AC ceiling fans incl. all accss. The capacitor of fan must be P-2 type brust proof. (Make - CG HS PLUS / EPC/Orient having Similar Specification) C3/21a.
Supply & Fixing of 36" ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. 36″ sweep, 230V 1-Ph. AC ceiling fans incl. all accss. The capacitor of fan must be P-2 type brust proof. (Make - CG HS PLUS / EPC/Orient having Similar Specification) C3/21a.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [D14/29 ]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand -Myrius/Arteor) on existing Modular GI switch board as per GS . [ 10 / E-18 ]
Engraving the deptt. number with 10 mm lettering on the body as per GS [ 24 (a) / C-3 ]
Extra for additional one letter incl. hifen, stroke and stop as per GS [24 (b) / C-3 ]
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS [ 26 (a) / C-3 ]
Extra painting for additional one letter of the engraved number as per GS [ 26 (b) / C-3 ]
Supply & Fixing of Heavy Duty Exhaust fans complete with all accessories ( Make -EPC )after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection.[28/C-4]
9"( 230mm ) Speed 1370 RPM
12"( 230mm ) Speed 1370 RPM
18"( 450mm ) Speed 920 RPM
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [ 32(a)/D-14 ]
Supply & Fixing of 230V , 50Hz ,400 mm sweep heavy duty full metal body wall bracket fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. [29/C-4] ( Make -EPC Tempest)
SUB-HEAD 8 -- MISCELLANEOUS
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. [20 (ab )/D-13 ]
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex/Hensel) of size [250X200X105]mm having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement, with DIN rail. on wall as per direction of EIC
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex/Hensel) of size [350X250X150]mm having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement, with DIN rail. on wall as per direction of EIC
S.I.T.C. of Astro Mini time switch [Make-L&T Cat no -T2DDT7 ]
Supply & Fixing of 3 pole contactors with 240 V operating coil as per direction by E.I.C.(Make: ABB Model:AX09)
Supply & Fixing of 3 pole contactors with 240 V operating coil as per direction by E.I.C.(Make: ABB Model:AX32-30-10).
SUB-HEAD 9 - AIRCONDITIONING WORK
S.I.T.C of 230V, 50Hz 4 star BEE rating 2 TR split type room air conditioner with rotary compressor and copper cooling coil & remote control operation complete with all other accessories including angle iron frame, Plug top as required.(Make:MITSUBISHI Heavy Duty model no.SRK 24 CS-S6/A, Refrigerant R410A or equivalent O General )
S.I.T.C of 230V, 50Hz 3star BEE rating 1.5 TR split type room air conditioner with rotary compressor and copper cooling coil & remote control operation complete with all other accessories including angle iron frame, Plug top as required. (Make:MITSUBISHI Heavy Duty model no.SRK 18CS-S6, Refrigerant R410A or equivalent O General)
Supply and fixing the followings :- i) 3-Core, 2.5 Sq.mm. PVC insulated copper power wire (Finolex / Havells) for inter - connecting indoor and outdoor unit. ii) copper refrigerant pipe line for inter connecting indoor & outdoor unit as following size a) 5/8" copper pipe including thermal insulation of suitable thickness as per direction of E.I.C. iii) copper refrigerant pipe line for inter connecting indoor & outdoor unit as following size : b) 1/4 " copper pipe including thermal insulation of suitable thickness as per direction of E.I.C.
Supply & laying Drain water pipeing work out of UPVC/HDPE pipes of 25 mm dia incl. Fitting accessories, bend,elbows, tees,flanges tapping wall sleeves, hangers, supports, anchors and with nitral rubber tube insulation.(HB/Supreme/Oriplast)
SUB-HEAD 10 - HIGH MAST INSTALLATION
S& Installation 20 mtr High Masts per Technical specification in C.C foundation (1:2:4) with tor steel rod and template & groutings bolts. (Note the drawing design of pole and base foundation would have to be submitted by the bidder for approval before execution of work if accepted). (Velmount / Skipper / Bajaj / Transrail / jindal / Utkarsh)
Techniocal Specification Hight of Mast : 20 mtr No. of Segment: 2 Material Construction: BS-EN 10025/IS 5986 Base & Top Dia ( Outer Dia): 530 mm & 150 mm Thickness: Top Section: 3mm Bottom Section: 4mm Cross Section of Mast: 20 sided regular polygon Galvanizing Standard: as per IS 4759 Metal protection: Hot dip Galvanizing internally & externally Thickness of Galvanization: 86 microns/above 600 gm per sq. m Size of inspection door opening: 1200mmx275mm (min) or OEM Standard. It should have close fitting door with allenkey locking suitable re-inforecment to avoid buckling. Provision for cable Terminal: Provision for MCB 4 pole 63A Base plate Diameter: 730 mm Base plate Thickness: 30mm
Lightning Protection Arrester: 2 mm Galvanized, Single spike No. of Longitudinal Weld: One longitudinal seamless joint No. of Circumferential Weld: Nil Length of individual Section: 10375 mm (min) Length of overlap: 750 mm (min) Type of joint: slip stress fit P.C.D. (details of template): 650mm Foundation Bolt Size: M30 x 1000mm No. of Anchor Plate: 750mm Dia x 6mm Thickness Dia of Cable Entry Pipe (PVC): 75mm Polythene pipe Wire Rope: Stainless steel Stopper Arrengement for Lantern Ring: Yes Dynamic Loading: as per IS 875 (3 sec Gust) Gear Box Fixing arrengment: as per OEM Junction Box: as per OEM to fit into the cavity of pole and inspection door.
Lantern Carriage Material Construction: IS 4923 GI Pipes (48 mm) Dia of Lantern Ring: 1200 mm in two Halves No of Luminaries: (max 12 nos) Type of fitting: (12x350 W) No of Joint: 2 Load Carring Capacity: 750 kg Buffer Arrengement: PVC Buffer
Trailing cable Conductor: 5 Core, 6Sq. Mm, Copper Insulation: PCP seathed, EPR coated Round
Winch & Power Tool No. of Drum of Winch: 2 Gear Material: Phosper Bronze Capacity 750Kg Method of operation: Manual/ Electromechanical Operating speed: 3 mtr/ min Lubrication Arrangement: Parmanent oil Bath Type of Lubricant: SAE 90/140
Power Tool Flame proof Motor (Make Crompton/ABB/Kirloskar): 3 HP with suitable gear for reduction of speed. Input Supply: 3Ph. 415 V Number of Speed: Single
Wire Rope Dia: 6mm No.: 3 Breaking Load: 2300 Kg/Rope Centre Core: SS Factor of safety i) For wind load: 1.25 ii) Other Load: 1.15
Supply & Fixing of 240V 350W LED flood light fittings with minimum 35000 lm output, vertical & horizontal both side tiltable base complete with all accessories of following beam angles. [ make: Philips /Wipro /Crompton]
S & Installation outdoor type both sided door feeder piller box on bricks foundation with cement plastering and net cement finish on a height of 18” from Gr. Level. The piller box will be fabricated from 3 mm thick sheet steel for body portion and 5mm thick for top portion (roof) . The size of the piller box will be 1200(H) x 1000(W) x 600(D) mm with base channel (size:- 75mm x 40mm x 6mm ). There should be horizontal & vertical flat iron (25mm X 6mm) structure in the middle for fixing Electrical accessories. Double Locking arrangement will be made with lock and duplicate keys (7 lever godrej, navatal lock) with door handle. Two numbers lighting arrangement with control switch to be made inside the box as working light and 1 no. 250V., 5/15 combined plug socket & switch. Painting will be made by synthetic enamelled paint after 2 coats of red led primer. Bricks foundation will be cement, plastering and neat cement finish. The feeder piller box comprising the followings:-
Front side: Supplying and fixing double door 160A, Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, incl. Inter connection with suitable size of copper wire and neutral link & provisionfor earthing attachment, 63A FP MCCB as incomer, 2nos 32A TP MCB & 6nos 6-32A SP MCB as out going. [Legrand make] Rear side: b) Supplying and fixing suitable size MS box (16SWG) with DIN rail & following accessories: 1. Astro Mini time switch [Make-L&T Cat no -T2DDT7 ], 2. 32A, 3 pole contactors MNX32 [Make-L&T Cat no -CS90241 ] with 240 v operating coil. 240V, 63A TP change over (MCB type) Havells make incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 3. 18 A 3 Pole contractor with 1 no N.O/NC auxiliary contact (Make L&T MO-18 Cat No. CS94835) or equivalent ABB/Legrand/Simence--------2 Nos 4. Electronic overload relay range (6-3 A) (L&T make Cat no. CS 9041800Q0/Legrand/Simence/ABB ---1 No. 5. Push button switch with enclose -----2 Nos (Legrand/Scheinder/L&T)
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts.[2(d)/G-1]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
S&F 50 mm x 6 mm galvanized (Hot Dip) steel strip in excess of 4mt for each earthing.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.[4(c)/G-2]
Supply & Erection of Single Steel tubular pole with sole plate & Cap etc. in CC foundation (410 SP - 26, 92Kg), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly. 9 mtr.
Supply and Fixing on pole with suitable GI bracket SMC Junction Boxes of dimention (250x200x105)mm with IP 67 protection (Sintex / Hensel )make for compound light. With 4 pole terminal stud and 6A 10KA C curve SP MCB Legrand make.
S&F 40mm dia class B MS pipe 1.5mt long arm bracket suitable for 50mm dia GI pipe pole with pole cap through bolt.
Painting of 9 mtr. Long steel Tubular pole with one coat of RO priming and Two coats of aluminium paint of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for recieving fresh coat of paint.[4(a)/H-2]
S & F 3x1.5 sqmm PVC copper wire in 13mm dia polithene pipe inside of ST pole / wall bracket for necessary connection as per direction by EIC.
S&F 90W LED street light fittings (Philips/ Wipro/ Crompton) with die cast aluminuim body & minmum luminious efficiency 110lm/ watt with all accessories with suitable tie clamps and MS plate for mounting on Pole.
Rate should be quoted including all Taxes, GST, LWC & other Duties (if any).
GHANASHYAM ELECTRIC STORES
DAS ENTERPRISE
stage.html
html • 0.05 MB
techsummary_630479.pdf
PDF • 0.09 MB
finance_630479.pdf
PDF • 0.04 MB
BOQ Comparative Chart
xlsx • 0.03 MB
finsummary_630479.pdf
PDF • 0.09 MB
AOC.pdf
PDF • 0.56 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .