Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹12.4 L
EMD Value
₹21,000
Closing Date
11 Feb 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BHUPENDER KUMAR DY. MANAGER
Power Grid Corporation of India Limited Saudamini, 3rd Floor Plot No.-2, Sector-29 Gurgaon (Haryana) - 122001
Supply, installation, Testing and Commissioning of street light on the side of defence road in front of PAL Complex, Manesar, Gurugram.
CC/NT/W-MISC/DOM/A15/24/17276
Open
Civil - All
Works
PAL MANESAR
₹1,250
₹21,000
23 Jan 2025
23 Jan 2025
13 Feb 2025
23 Jan 2025
11 Feb 2025
23 Jan 2025
Supply, installation, Testing commissioning ( SITC) of 07 meter length octagonal / tubular street light poles with all acessories like foundation bolt, base plate, 1.5 meter length arm for holding led Fixture & cover the top part of pole and etc.. At the bottom part of pole structure having inbuilt juction box with SS rail, Single pole 10A MCB, terminal block - suitable for 4 core 10 Sq mm Aluminium armoured cable connection, suitable size lugs etc required for completion of this work.The materail not specified but required for SITC of street light pole is in the scope of vendor without any financial implication to POWERGRID. The detail information mention in technical specification
Supply, installation, Testing commissioning of 60W C/W or W/W street light having IP 66 protection. The detail information mention in technical specification
Supply, installation, Testing commissioning of 4 core 10 Sq mm Aluminium armoured XLPE cable
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 X 1.5 Sq MM from Juction Box to Light Fixture
Supplying and fixing of horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 4 way (4 + 12), Double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 63 A
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required - Upto 35 sq. mm
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. - All kinds of soil.
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Finishing walls with water proofing cement paint of required shade - New work (Two or more coats applied @ 3.84 kg/10 sqm)
Total
i) To facilitate the bidders, POWERGRID has indicated HSN/SAC Code and rate of GST against BOQ items . It shall entirely be the responsibility of the bidder to check HSN/SAC Code and rate of GST. The bidder may either confirm the HSN/SAC Code and rate of GST or if the bidder opts to classify the item in question under a different HSN/SAC Code and rate of GST, bidder may indicate the same in the columns provided. The bidders shall solely be responsible for the HSN/SAC Code and rate of GST for each item. Employer’s liability for reimbursement of GST shall be lower of the GST applicable at the rate as confirmed/deemed confirmed in the bid or actual GST paid/payable by the bidder for that item.
ii) In case the bidder leaves the cell for confirmation of HSN/SAC Code and GST rate "blank", corresponding HSN/SAC Code and GST rate indicated by the Employer shall be deemed to be the one confirmed by the bidder. iii) Bidder shall quote rate of all items. Any partially quoted bid shall be treated as nonresponsive and may lead to rejection.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
PRICE_SCHEDULE.xlsx
xlsx • 0.02 MB
1_Section I IFB.docx
docx • 0.14 MB
2_SECTION II ITB Revised.docx
docx • 0.17 MB
3_Section III GCC-1.docx
docx • 0.04 MB
4 Forms Section IV.docx
docx • 0.09 MB
6_SECTION V TS and SCC.docx
docx • 0.22 MB
Affidavit for Self-Certification-PPP-MII.docx
docx • 0.02 MB
MSE Purchase Preference.docx
docx • 0.02 MB
Section-VI -QR.docx
docx • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .