| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.8 LAccepted-Finance | L1 | Accepted-Finance Reasonable L1 rate | |
| 2 | L2₹68.8 L+₹8.1 L (13.3%)Rejected-Finance 8 99 GROUND FLOOR GEETA COLONY NEW DELHI DELHI 110031 | SHAHDARA | DELHI | 110031 | L2 | Rejected-Finance Above the LI rate | |
| 3 | L3₹69.0 L+₹8.2 L (13.5%)Rejected-Finance | L3 | Rejected-Finance Above the L1 rate |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
14 Jul 2020, 12:00 pmClosed
IGP NS CRPF
IGP NS CRPF WEST BLOCK - VIII, R.K.PURAM NEW DELHI-110066
supplying , installation, tensting and commissioning of VRF/VRV Air conditioning work in CRPF officers institure (shaurya) at vasant Kunj, new delhi.
2020_CRPF_569830_1
L-VII-1/2020-21-Q (NS) -Shourya (AC-PLANT)
Open Tender
Electrical Works
Works
90 days
Vasant kunj New Delhi
as per NIT Documents.
13 documents required · 13 mandatory
₹0
₹1.5 L
9 Oct 2020
8 Jul 2020
15 Jul 2020
8 Jul 2020
14 Jul 2020
8 Jul 2020
8 Jul 2020 - 14 Jul 2020
Supply of variable refrigerant flow Air conditioning system Heating & Cooling both for Indoor and Outdoor Unit suitable for cooling & Heating both by multiple scroll compressor controlled by individual inverter complete with indoor and outdoor units. 48 HP
Supply erection testing and commissioning of ceiling concealed Ductable type unit VRF IDU Duct able in the Ceiling with fitting consisting of centrifugal fan, three speed motor, coil section with DX coil, outdoor cabinet, filter insulated drain pan including all accessories complete as required 16 HP minimum 5250CPM
Supply, erection, testing and commissioning of cassette type VRF IDU unit 4 HP
Supply of VRF OEM manufacture treated fresh air unit(TFA) consisting of fan, coil, section with DX coil, outdoor cabinet, filter including all accessories complete as required 16 HP(12.8 TR 2330 CFM)
Supply of VRF Coroded remote controllers suitable for above indoor units to operate, ON/OFF temperature setting, air changing etc. The remote controller shall be suitable for wall mounting with bracket Wired remote controller
Supply of central comptroller for indoor& Outdoor Unit capable of controlling of all IDUs complete with necessary hardware, accessories etc to perform the following function Control of IDUs, ODUs units as above with monitoring of vital parameters such as temperature sensing & setting ON/OFF status etc
Installation, testing and commissioning of variable refrigerant flow modular type Air-conditioning system of in-door and out- door unit suitable for cooling & Heating both by multiple scroll compressor controlled by individual inverter complete with indoor and outdoor units 48 HP
Erection, testing and commissioning of ceiling concealed VRF IDU duct able type unit with fitting consisting of centrifugal fan, three speed motor, coil section with DX coil, outdoor cabinet, filter insulated drain pan including all accessories complete as required 16 HP minimum 5250CPM
Erection, testing and commissioning of VRF IDU cassette type unit with fitting consisting of fan, four speed motor, coil section with DX coil, outdoor cabinet, filter insulated drain pan (with inbuilt drain pump) including all accessories complete as required 4 HP
Erection, testing and commissioning of VRF OEM manufacture treated fresh air unit(TFA) consisting of fan, coil, section with DX coil, outdoor cabinet, filter including all accessories complete as required 16 HP(12.8 TR 2330 CFM)
Installation, testing and commissioning of VRF Corded remote controllers suitable for above indoor units to operate, ON/OFF temperature setting, air changing etc. The remote controller shall be suitable for wall mounting with bracket Wired remote controller
Installation, testing and commissioning central comptroller of all IDUs, ODUs complete for indoor and outdoor unit
Supply, installation, testing and commissioning refrigerant Y joint Pipe required for distribution of refrigerant in copper piping etc complete as per specification
Interconnecting refrigerant pipe work 44.45 mm OD(With 19mm insulation)
Interconnecting refrigerant pipe work 38.1 mm OD(With 19mm insulation)
Interconnecting refrigerant pipe work 34.9 mm OD(With 19mm insulation)
Interconnecting refrigerant pipe work 31.75 mm OD(With 19mm insulation)
Interconnecting refrigerant pipe work 28.6 mm OD(With 19mm insulation)
Interconnecting refrigerant pipe work 25.4 mm OD(With 19mm insulation)
Interconnecting refrigerant pipe work 22.2 mm OD(With 19mm insulation)
Interconnecting refrigerant pipe work 19.05 mm OD(With 19mm insulation)
Interconnecting refrigerant pipe work 15.9 mm OD(With 19mm insulation)
Interconnecting refrigerant pipe work 12.7 mm OD(With 19mm insulation)
Interconnecting refrigerant pipe work 9.5 mm OD(With 19mm insulation)
Supply, testing, installation and fixing of heavy duty class B PVC pipes ISI 4985-2000 drain piping complete with 6 mm thick aluminum laminated XLPE tubular insulation fitting support as per specification 32 mm Dia
Supply, testing, installation and fixing of heavy duty class B PVC pipes ISI 4985-2000 drain piping complete with 6 mm thick aluminum laminated XLPE tubular insulation fitting support as per specification 25 mm Dia
Supply, testing, installation of 2 core x 1.5 mm copper wire with PVC conduit as per specification (For transmission)
Supply, testing, installation of 2 core x 1.5 mm copper wire with PVC conduit as per specification (For Remote)
Supply, testing, installation of 3 core x 2.5 mm copper wire for power supply for indoor unit t as per specification
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting for air distribution complete with neoprene rubber gaskets, elbows, splitter, dampers, vanes, hangers supported etc as per approved drawing and specification of following sheet thickness complete as required 24 Gauge
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting for air distribution complete with neoprene rubber gaskets, elbows, splitter, dampers, vanes, hangers supported etc as per approved drawing and specification of following sheet thickness complete as required 22 Gauge
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gasket, nut, bolt, screws linkage, flanges etc as per specification
Supply installation, testing and commissioning of opposed blade aluminum volume control collar dampers(in mat black finish) in supply air grill/diffusers collar damper shall be aluminum body and blade aluminum construction complete with nut bolt screw linkers etc as per approved shop drawing and specification
Supply and fixing of powder coated extracted aluminum supply air grill with aluminum volume control dampers complete as required
Supply and fixing of powder coated extracted aluminum return air grill with louvers but without volume control dampers complete as required
Supply and fixing , testing and commissioning of supply/return air diffusers of powder coated aluminum volume control dampers with anti smudge ring & removable core
Supply and fixing , testing and commissioning of return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring & removable core
Supply and fixing , testing of round shape butterfly damper of MS construction if following size Butterfly damper 250 mm
Supply and fixing , testing of round shape butterfly damper of MS construction if following size Butterfly damper 300 mm
Supply and installation of Spill air boxes for air distribution above the diffuser/grill 450mm
Supply and installation of Spill air boxes for air distribution above the diffuser/grill 300mm
Supply and installation of pre insulated flexible duct for connection between butterfly damper to spill air boxes same shall be along with necessary clamps 250mm Dia
Supply and installation of pre insulated flexible duct for connection between butterfly damper to spill air boxes same shall be along with necessary clamps 300mm Dia
Supply fabrication installation and testing the flexible connection constructed of fire resistance flexible double canvas as per the approved shop drawing
Supply installation and testing of fresh air/exhausted air powder coated anodized extracted aluminum construction fresh air louvers(50mm deep)(Fresh air louvers with VCD, bird screen& rattle-free) complete as per specification
Supply and installation of Nitrile rubber closed cell insulation materials with antimicrobial property. 9 mm thickness insulation
Supply and installation of duct acoustic insulation inside the duct with open cell XLPE to be applied using manufacture 10mm thick acoustic lining complete as required and as per specification.
Supply and erection of GI perforated cable tray with DA gray paint on the existing surface with the help of MS angle iron MS perforated cable tray size 200mmx50mmx 25mm(2mm) support(to be painted with approved paint) of given size to be fixed with fasteners/nut& bolt etc on the duly painted, L-angle, U bended type support complete in all respect as desired MS perforated cable tray size 200mmx50mmx 25mm(2mm)
TRANSCEND CONTRACTS PVT. LTD.
CONSISTENT AIRCON PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .