| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC CHAMAVILA CHEELI CHITTADI POST PALAKKAD DIST KERALA 678706 | PALAKKAD | KERALA | 678706 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.4 L+₹1.3 L (2.60%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹49.4 L+₹1.3 L (2.61%)Rejected-Finance 121004 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹50.6 L+₹2.4 L (5.03%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹51.2 L+₹3.1 L (6.35%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
9 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
CERTAIN SANCTIONED WORKS AT TECHNICAL AND DOMESTIC AREA AT AFS SULUR
2020_MES_387664_1
8369/E8
Open Tender
Miscellaneous Works
Item Rate
210 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹1 L
Yes
17 Nov 2020
19 Oct 2020
10 Nov 2020
19 Oct 2020
9 Nov 2020
3 Nov 2020
19 Oct 2020 - 31 Oct 2020
60 days
Amount
SCHEDULE A BOQ
Demolition of Concrete (unreinforced) of any description and in any position not otherwise specifically provided all as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out sof/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
Cement concrete type C-2 1:3:6 using 40mm graded aggregate as in foundations, filling and mass concrete complete
Mild steel plates, (plain or chequered) 8mm thick or over in thickness in available sizes Fe-410-W(Gde- E- 250) quality-B forming holes without any attachement all as specified.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 but n exc 10cm long and dia of neck 5 to 10mm complete
Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290. Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel')
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS:1161- 1979 grade St.-240
Welding in repairs, exc 2,5 cm but n exc 5 cm in length with thickness of metal to be welded n exc 6 mm.
Cleaning/greasing/oiling of hangar wheel track at top of any description, welding of members if required tightening of screws/ nuts, bolts of door and wheels etc including rectifying the alignment of top guide channel/ rail/ angle etc complete for smooth functioning of hangar doors.
Remove the existing damaged filled sealing compound including polyethylene rod by raking end using blow lamp and cleaning of expansion/construction/dummy joints of concrete pavement free from dust and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surfaces to give a neat finish to the sealant,provision of polyethylene backup rod 10-14 mm dia in construction/dummy joint and sealed with COLPOR 200 polyurethane based sealing compound 10-12 mm thick above back up rod confirming to BS 5212-1990 or equivalent of approved colour after application of suitable primer and removing the masking tape after the sealant filling etc complete all as specified and as per manufacturers instructions. The size of the joint is 8 to12mm wide for construction/dummy joint.
Note for item No 11 :- (a) The existing sealant compound shall be taken out completely using blow lamp and joint shall be cleaned with wire brush and loose particles dust etc shall be removed by using hand pump before applying primer.
(b) Any spillage of material during filling over the slab shall be removed and cleaned by contractor and any damage accrue to the concrete slab will be made good by the contractor without any extra cost to the department.
Note:- (i) Material shall confirm to BS (manufacturer : FOSROC (COLPOR-200 gray) or Chemtallraj India Pvt Ltd. (RALLITHANE) or STP Ltd (Shalifax PU) or (CICO OR) Cippy ply seal.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe- 410 W, Gde E- 250 quality)
M&L for preparation of new or previously untreated steel surfaces over 10cm girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
Note for item No 16 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
Wash basin vitrous china (flat back and angle back Type) size 630 x 450mm including taps waste chain and plug and porceline stopper but brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe, fixed in repair all as specified.
Angular stop cock, valves high pressure screwed both ends iron pipe or for unioins 15mm bore dia of pipe CAT Part No G3007A1 of Parryware or equivalent to Hindware/ ESS-ESS, including taking down existing one Complete all as specified and as directed
32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
Cast iron floor trap dia of outlet 75mm, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified
110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors as speicified and as directed
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) all as directed.
M&L Cement concrete 25 mm thick type B2 1:2:4 (12.5 mm graded aggregate) as in flooring all as directed.
Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in for skirting/ vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:4 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Note for item No 32 : Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. NOTE : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing
Broken stone or boulders hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n.exc 15 CM thick watered and rolled /rammed to a true surface all as specified and as directed by Engr-in-Charge.
Cement concrete 1:2:4 type B-2 ,100 mm thickness ( using 40 mm graded stone aggregate) to recive tile complete all as specified and directed.
Chequered cement concrete tiles 30cmx30cmx25mm thick machine pressed set jointed and pointed in neat cement slurry as in floors and cut and polished using gray cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) as directed Note :- The manufacturer's test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
Dismantling plain or corrugated steel sheeting any gauge including Nainital or similar pattern in roof covering all as specified and as directed.
Pre painted corrugated Coloured Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws all complete all as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as directed.
Note for Pre-painted coloured Galvalume roofing :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
(iv) The contractor shall produce purchase vouchers for each lot for verification of Engineer-in-Charge.
Cleaning/greasing/oiling of hangar wheel track at bottom of any description, welding of members if required tightening of screws/ nuts, bolts of door and wheels etc including rectifying the alignment of top guide channel/ rail/ angle etc complete for smooth functioning of hangar doors.
Remove the existing damaged filled sealing compound including polyethylene rod by raking end using blow lamp and cleaning of expansion/construction/dummy joints of concrete pavement free from dust and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surfaces to give a neat finish to the sealant,provision of polythethylene backup rod 25 mm dia in any type of joint and sealaed with 10-12 mm thick COLPOR 200 polyurethane based sealing compound confirming to BS 5212-1990 or equivalent of approved colour after application of suitable primer and removing the masking tape after sealant filling etc complete all as spd and as per manufactures instructrions . The size of joint is 20 mm wide for any type of joint.
Note for item No 46 :- (a) The existing sealant compound shall be taken out completely using blow lamp and joint shall be cleaned with wire brush and loose particles dust etc shall be removed by using hand pump before applying primer.
(b) Any spillage of material during filling over the slab shall be removed and cleaned by contractor and any damage accrue to the concrete slab will be made good by the contractor without any extra cost to the department.
Note:- (i) Material shall confirm to BS (manufacturer : FOSROC (COLPOR-200 gray) or Chemtallraj India Pvt Ltd. (RALLITHANE) or STP Ltd (Shalifax PU) or (CICO OR) Cippy ply seal.
Wind operated Turbo Ventilators of size 24 inches dia with FRB base plate material of construction for ventilator is high grade Industrial Aluminium of thickness not less than 0.5mm. Material of construction of hardware is stainless steel -304. Bearing shall be steel in completely enclosed and dustproof integrated housing and aligned with each other, it shall have capability to rotate at nearly zero wind speed. Turbo ventilator shall have UV stabilized powder coated and capable of static balancing shall have high exhaust capacity and there shall not be any exhaust problem due to air block draft. Fixing arrangement shall have high quality rubberised hardware to prevent rain ingren. All Turbo Ventilator to be installed by manufacturer's auth person only. Contractor shall give no leakage guaranty for period of three years from the date of installation of Turbo Ventilator all as specified and as directed. Make : M/S Turbo Ventilators, M/S SVS Wind Driven Turbo Ventilators, M/s Arven Turbo Ventilators.
Vitreous china wash down water closet pan (pedestal pattern), white (exluding fixing bolts,flushing cistren and flushpipe) and including seat cover for pedestal pattern complete including taking down existing one Complete all as specified and as directed all as specified and as directed.
PVC Dual flush ceramic colour , low level, 10 litres capacity, star white with inlet float ball valve, PVC flush pipe and handle, making proper fixing and hanging arrangements Cat Part No 21029 of - hindware or equivalent in Parryware, ESS-ESS including taking down existing one Complete all as specified and as directed
PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement
S&F Cast iron soil Waste and vent pipes 75 mm in any length with or without ears with cement joints fixed to wall
Pillar taps 15mm bore dia of pipe CP with capstan head screwed down high pressure screwed for iron pipe Cat Part No CQT -23021KN of Jaquar or equivalent to /Parryware/Hindware/ Cera including taking existing one complete as directed by Engr-in-charge.
Preparation of old surface of walls by using pressure washer, remove of existing treatment all dirt & dust ,applying one coat of wall care putty and then applying two coats of oil bound distemper of required shade complete all as specified and directed by Engineer - in - Charge. Note:-(i) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
Polycarbonate transperant sheet similar to the profile of galvalume sheet 2mm thickness with two corugations sice lap fixed with self tapping screws/J hooks 8mm dia in roof, wall etc complete all as specified and as directed.
Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in for floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:4 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Note : Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. NOTE : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing
Two coats of aluminium paint on old steel surfaces over 10 cm girth over a coat of primer including scraping down the rusted scales etc and preparation of old surfaces all specified and as directed.
Gypsum board plain ceiling using GI perimeter channel with wall, main channel and Intermediate channel and GI angle suspender from the soffit at 1220mm centre to centre fixed with GI Cleat and steel expansion fasterners ceiling section fixed to the Intermediate channel with help at connectiong clips and in direction perpendicular to the intermeidate channel at 600mm centre and 12.5mm thick Gypsum board Saint Gobain(Gyproc) is then screwed with ceiling section with 25mm screws at 300mm centres Finally the gypsum board are to be jointed and finished with jointing compound/ jointing paper tape and preparartion surfaces and applying two coats of oil bound distemper including taking down of existing ceiling board of description all as directed by Engineer-in-Charge.
Preparation of old plastered surfaces of wall by using pressure washer, removal of existing treatment all dirt and dust and applying one coat of exterior emulsion paint complete all as specified and as directed. Note:-(i) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
Taking down carefully copper/Alu point wiring from steel conduit and PVC casing capping or any type (light, fan. socket or power) complete including fixtures and fitings such as switches, ceiling roses, pendents, regulators, sockets , light fitting etc and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separetely) and making good distrubed surfaces of walls, floors etc.
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl Steel Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
(a) One light point/fan/bell point controlled by one switch
(b) All as per item No. 64 here in before but for One 3 pin socket out 5 amp on the same board
(c). All as per item No. 64 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 64 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC casing caping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Havells/ Polycab Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
(a) One light point/fan/bell point controlled by one switch
(b) All as per item No. 69 here in before but for One 3 pin socket out 5 amp on the same board
(c). All as per item No. 69 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 69 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Modular switch 6 Amps 240 volts single pole one way, 1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Modular switch 16 Amps 240 volts single pole one way, 1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Modular socket outlet multipurpose 2/3 pin 6 amps, 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Mdular socket outlet multipurpose 2/3 pin 6/16 amps, 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
White cover plate with frame, 3 Module.
White cover plate with frame, 6 Module.
White cover plate with frame, 8 Module.
Metal flush box 3 module.
Metal flush box 6 module.
Metal flush box 8 module.
Electronic modular fan regulator 230 volts, step type socket type, hum free 120 watt 2 Module. Make :- Havells, Crabtree, Legrand
Ceiling rose, surface type Bakelite 65x55mm 3 terminal
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping including cutting of chases for lying conduit making good the surfaces as per existing surfaces or as directed for concealed and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing one complete all as specified and directed.
Note for item No 86 : (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor, PVC casing capping shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Factory made powder coated distribution board TPN 4 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete and conforming to IS : 8623 all as specified and directed. Make :- Legrand/ Siemens/ Schneider
Factory made powder coated distribution board SP&N 12 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete and conforming to IS : 8623 all as specified and directed. Make :- Legrand/ Siemens/ Schneider
Triple pole Neutral MCB 63 Amp, 415 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity including taking down existing one complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408683 or equivalent. of Schnieder (Multi -9) Siemens/L&T (Hegar).
MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity including taking down existing one complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408617 or equivalent. of Schniede, Siemens/L&T.
Metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Make : Cat Pt No 607841 of Legrand or equivalent of Schnieder (Multi -9)/ L&T (Hegar).
Removing and refixing of existing LED down light 30/36 W recess/ surface mounting 2' x 2' all as specified and directed by Engineer-in-Charge.
36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted; Test Certificate to be submitted; Certification : LM 79 for luminaire & LM 80 for LED source. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 365 BLED 33-6500 PSU OD WH or equivalent in Wipro.
Supply, installation, testing and commissioning of horizontal type with hard top deep freezer 300 ltr capacity single phase, 240V, 50 Hz with energy efficient compressor having various level of compartment complete all as specified and as directed. Make :- Blue Star, Voltas, LG
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit/ casing capping and all accessories fixed to wall/floors along with one run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and PVC conduit/ casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size of brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Metal clad socket single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps concealed in wall. Make :- Legrand/ Schneider/ L&T
Supply and fixing on distribution boards, replacement, single pole MCB 10 to 32 Amps, 240 V, 50 Hz AC suitable for 'C' curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified. Make/ Model : Lexic MCB of MDS Legrand Cat No : 408590 to 408595 or equivalent of Schnieder/ L&T.
4 feet surface mounted batten type 20W LED luminaire with emergency light output, shall be maximum 4 hours battery backup in case of power failure with Li battery, luminaire efficacy 100 lm/w with an operating voltage range from 140V - 270V, initial lumen at battery mode will reduce to 35 - 50%, charging time appox 8 - 12 hours. The luminaire shall have aluminium extruded main housing, PC LED front cover. The luminaire shall have a CCT of 6500K, CRI >80, Power factor >0.95, THD <30%, driver efficiency > 85%, electronic control gear, CC driver and 50,000 burning hours as per L70 B50 criteria. The luminaire shall be EMI/ EMC complaint and shall have open and short circuit protection, reverse polarity protection, internal surge protection of 3.0 KV, IP 20 ingress protection. Make :- Halonix Model No : HLB-08-20-CW-INV or equivalent of Philips/ Bajaj
Note for item No 100 :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid, Seoul semiconductor. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Supply and fixing 30 watt LED Inverter RTC Street Light with inbuilt RTC (Real Time Clock) for AUTO ON/ AUTO OFF and must have DIMMING facility from 10 to 100% of Rated wattage as per user defined timeline. Housing made of Pressure Die Cast Aluminium, TOP MAINTAINABLE and with clear heat resistant toughened glass, should have secondary lens for better optics, should have Constant current RTC enabled electronic driver with 5 KV SPD, IP66. Street light shall have inbuilt Li-ion battery of 5200 mAH and shall have >1.5 hrs battery backup at inverter load in case of power failure, Efficacy > 100 LPW, CRI > 70, THD <10%, PF >0.95, Cut off Voltage at 300 Volt + 10% and suitable for 50mm mounting pipe. Make :- Halonix Model No : HLSLD-ML04-30-CWL-INV-RTC-DIMM or equivalent in Philips/ Bajaj
Note for item No 102 :- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Factory made powder coated distribution board SP&N 8 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete and conforming to IS : 8623 all as specified and directed. Make :- Legrand/ Siemens/ Schneider
Supply and fixing energy efficeint Ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long, writing MES No 2 cm height with synthetic enamel paint complete all as specified and as directed. Make : Havells cat Part No. ES Neo or equivalent in Bajaj/ Orient. Note:- The contractor shall given a written guarantee of minimum two years from completion of work.
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size metallic steel conduit including cutting of chases for lying conduit making good the surfaces as per existing surfaces or as directed for concealed and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing one complete all as specified and directed.
Note for item No 106: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor, PVC rigid conduit shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F factory made powder coated distribution board SP & N 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete and conforming to IS: 8623 all as specified. Make/Model : Legrand/ Siemens/ Schnieder
Single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 including taking down existing one all as specified Make/Model : Legrand Cat No : 408587 to408595 or equivalent. of Schnieder, Siemens/L&T.
Supply and fixing 45 watt LED Inverter RTC Street Light with inbuilt RTC (Real Time Clock) for AUTO ON/ AUTO OFF and must have DIMMING facility from 10 to 100% of Rated wattage as per user defined timeline. Housing made of Pressure Die Cast Aluminium, TOP MAINTAINABLE and with clear heat resistant toughened glass, have secondary lens for better optics, should have Constant current RTC enabled electronic driver with 5 KV SPD, IP66. Street light shall have inbuilt Li-ion battery of 5200 mAH and shall have >1.5 hrs battery backup at inverter load in case of power failure, Efficacy > 100 LPW, CRI > 70, THD <10%, PF >0.95, Cut off Voltage at 300 Volt + 10% and suitable for 50mm mounting pipe. Make :- Halonix Model No : HLSLD-ML04-45-CWL-INV-RTC-DIMM or equivalent in Philips/ Bajaj
Note for item No 110- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
60W LED inverter Flood light with inbuilt real time clock (RTC) for auto ON/ OFF feature, emergency light output, shall have maximum 1.5 – 2 hours battery back up with Li-ion battery at inverter load in case of power failure, system lumen not less than 100 lumen, initial lumen at battery mode will reduce to 15-20%. Housing made up of pressure dicast aluminium body with Top maintainable and front cover clear toughened glass, with IP 66 and IK05 protection, open and short circuit protection, reverse polarity protection, high voltage cut off at 300V + 10V and 5 KV internal surge protection, PF > 0.95, THD < 10% and Driver Efficiency > or = 85%. CRI > or = 70. Make :- Halonix Model No - HLFLD-ML30-60-CWL-INV-RTC-DIMM or equivalent of Philips/ Bajaj.
Note for item No 112:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(vii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(viii) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(ix) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(x) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xi) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(xii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xiii) The electrode shall carry manufacturer's name .
(xiv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply & installation of CEASEFIRE Clean Agent Based Stand alone automated (Modular) Fire Suppression systems (HCFC 123) - 5 Kg MS SP Red. SPECIFICATION : (a) Capacity - 5 Kg. (b) Gross weight - 7.7 Kg. (c) Empty weight - 2.7 Kg. (d) Can Height - 264mm. (e) Diameter - 240mm. (f) Discharge time - Min 8 secs. (g) Discharge mechanism - Automatic (h) Applicable of class A, B, C and electrically started fire. (j) Can construction - Deep drawn & CO2 Mig welded. (k) Valve construction - Forging & Machining. (l) Internal coating of Can - Epoxy Powder Coating (m) External coating of Can Epoxy Polyster Powder coating. (n) Tests - Helium Leak Detection. (o) Sheet metal thickness -1.60mm (p) Warranty - 06 year.
Supply & installation of RAVEL Smoke detector (RE 316 UL)
Supply & installation of RAVEL 2 Zone panel (RE 102)
Supply & installation of RAVEL MCP (RE 716 MR)
Supply & installation of RAVEL Hooter (RE 24 CS)
Supply & laying of 2 x 1.5 sqmm flexible cable and testing, commissioning of complete fire alarm system.
J and K constructions company
Neptune Engineers and Builders
pk janardhanan
Sreekrupa Enterprises
NAVEEN ENTERPRISES
SUPER COOL
Sreyas Enterprises
devan enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .