Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.1 LAccepted-AOC SAARTHAK 382 2 PLOT NO 36 2 OM NAGAR 1ST CROSS KHASBAG BELGAUM KARNATAKA 590 003 | BELAGAVI | KARNATAKA | 590003 | L1 | Accepted-AOC L1 | |
| 2 | L2₹88.5 L+₹5.1 L (6.17%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹91.7 L+₹8.4 L (10.1%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹92.7 L+₹9.4 L (11.2%)Rejected-Finance S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹93.5 L+₹10.1 L (12.2%)Rejected-Finance | L5 | Rejected-Finance Not L1 |
Tender Value
₹88.1 L
EMD Value
₹1.8 L
Closing Date
22 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE No 2 Secunderabad
CWE No 2 Secunderabad, Mudfort, MES Complex, Secunderabad-03
SPL REPAIRS TO BLDG NO.12 ABOS (RANJIT HOUSE) AT RASHTRIYA MILITARY SCHOOL BELGAUM UNDER GE BELGAUM
2022_MES_514276_1
81094/E8
Open Tender
Civil Works
Item Rate
365 days
GE Belgaum
As per tender documents
7 documents required · 7 mandatory
₹1,000
Yes
GE Belgaum
₹1.8 L
Yes
4 May 2022
17 Mar 2022
29 Apr 2022
17 Mar 2022
22 Apr 2022
8 Apr 2022
60 days
Amount
Dismantling plain or corrugated steel sheeting, any gauge, thickness in roof coverings all as specified and as directed.
M&L second class hardwood in scantling clean sawn timber fixed including dismantling timber scantling 40 Sqcm and over in section in any position unframed work all as specified and as directed.
All as per item No 2 above but fixing only timber all as specified and as directed.
S&F Steel work in tubular trusses, posts,rafters, struss etc including special shaped washers etc. complete using ERW or induction butt welded tubes all as specified and as directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 410-0 or Fe 310-0 (Brackets over 10kg each to be measured under `Structural Steel') as in cleats all as specified and as directed.
S & F Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws including dismantling single layer Mangalore pattern or similar tiles in roofing and battens for tiles, shingles etc of any size including tilting fillets spaced exc 15 cm all as specified and as directed.
S & F Prepainted galvalume aluminum zinc coating GI based Plain steel sheet in ridge, 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws including dismantling single layer Mangalore pattern or similar ridge tiles in roofing and battens for tiles, shingles etc of any size bedded in lime or cement mortar all as specified and as directed.
S&F mild steel flats for wind ties for roof including securing bolts & similar work conforming to Fe 410-0 or Fe 310-0 all as specified and as directed.
M&L PCC 1:3:6, type C-1, using 20mm graded stone aggregate as in eves filling between wall and sheet including demolition of plain cement concrete of any description and in any position not otherwise specifically provided all as specified and as directed
Preparing surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with one coat of creosote all as specified and as directed.
Taking down shutters of any description n exc 1sqm each all as specified and as directed.
Taking down shutters of any description exc 1sqm and n exc 2 Sqm all as specified and as directed.
Taking down shutters of any description exc 1 sqm and n.exc 2 sq.m each and refixing in the same opening all as specified and as directed.
Taking down chowkhat with shutters without taking off shutters from the frame area exc 1.5 Sqm and n exc 4 Sqm each all as specified and as directed.
S&F 2nd class hard wood chowkhat or frames, plain, solid, wrought, framed and rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified and as directed.
M&L 35mm thick second class hard wood, plain framed panelled shutter (two panels) with lock rail and panel of 9mm thick plywood BWR 5 Ply with commercial veneers on both faces with size of rails and stiles sizes of members of shutters are specified in SSR Part-I, Section 8 Clause 8.24 (a) and fitted to chowkats all as specified and as directed.
M&L 30mm thick 2nd class hardwood glazed /Gauzed and skeleton shutter open rebated and prepared to receive glass, gauze etc(divided into squares with plain, chamfered or rounded mitred and rebated sash bar any numbers), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters are specified in SSR part-I section 8 clause 8.24 (b) and fitted to chowkats all as specified and as directed.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in squares n exc 0.5 Sqm in each pane including hacking of existing glass all as specified and as directed.
S&F MS butt hinges cold rolled medium weight 100mm size all as specified and as directed.
S&F MS butt hinges cold rolled medium weight 75 mm size all as specified and as directed.
S & F Aluminium anodised barrel tower bolt of extruded section of size 150mm long all as specified and as directed.
S & F Aluminium anodised barrel tower bolt of extruded section of size 100mm long all as specified and as directed.
S&F 150 mm long extruded section aluminium alloy anodised handles fabricated type all as specified and as directed.
S&F 100mm long extruded section aluminium alloy anodised handles fabricated type all as specified and as directed.
Supply and fix aluminium alloy anodised sliding door bolt 300mm long with hasp & staple (Bolt type) and fixing clips of sheet cast or extruded section of cast aluminium alloy complete all as specified and as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40mm fixed in panel of joinery all as specified and as directed.
M&L preparing surfaces of wood or wood based surfaces over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of pink primer all as specified and as directed
S&F High pressure steam cured (HPSC) non asbestos fibre cement building board 4mm thick in false ceiling with aluminum anodized snap grids of 60x60cm in ceiling with Tee section 35x25x1.25mm, angle section25x25x1.25mm thick including 2mm dia GI hanging wire and all hanger fittings etc and provision of three coats of white wash on exposed surfaces of ceiling including dismantling ceiling and wall boards or insulation board any thickness including cover fillets all as specified and as directed.
M & L for complete removal of exististing treatment and applying two coat of exterior acrylic emulsion paint over Alkali resistant priming coat on plastered surfaces including preparation of surface of walls all as specified and as directed.
M&L for Preparing old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed.
Preparation of new surfaces of steel of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
M&L for two coats of oil bound distemper (Acrylic distemper washable) over a coat of primer over 1mm thick layer of wall care putty, on wall, pilasters, cornices etc including complete removal of existing treatment and necessary preparation of surfaces all as specified and as directed.
PVC (SWR) pipes 110mm single socketed in any length with rubber ring joints fixed to walls with required iron strap or clamp all as specified and as directed.
S&F PVC (SWR) eaves gutter trapezoidal profile160mm dia all as specified and as directed.
Taking down cement plaster on brick or stone walls,etc. including raking out joints, hacking for key, scrubbing down with water,etc. all as specified and as directed.
M & L precast cement concrete block masonry (1:3:6) type C1 (20mm graded aggregate) masonry with solid block exc10cm in width and setting in CM 1:6 etc complete including demolition of PCC block masonry built in cement mortar all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1: 6 on fair faces of PCC block work or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5mm thick in cement mortar 1: 4 with water proofing compound over 10mm thick back rendering in cement mortor 1:6 on fair faces of brick work/block masonry or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed.
Supply only integral water proofing compound all as specified and as directed.
M&L preparing new plastered surfaces of wall by washing down & applying two coats of oil bound distemper over a coat of chalk whiting all as specified and as directed
M & L for two coat of exterior acrylic emulsion paint (Apex paint) over Alkali resistant priming coat on newly plastered surfaces including preparation of surface of walls all as specified and as directed.
Dismanting of two way trellis work (jafri), including taking as under of battens of trellis (posts and rails measured separately) all as specified and as directed.
Structural steel, rolled section such as joist, beam, channel, angle, tee, in available lengths 'Fe 410-W (Gde E-250) quality A all as specified and as directed.
Welded steel wire fabric 'Weight per square metre 'Not exc 4 kg all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for grills etc all as specified and as directed.
S&F mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted or forget into spikes; framed guard bars; barred iron doors; framed ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
M&L for Plain cement concrete 1:3:6, type C2 using 40mm graded stone aggregate, 75mm thick as in plinth protection, path etc, and finishing the surface even and fair including demolition of cement concrete in ground floors n.exc 15 cm thick all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block glozzy finish with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade over and including 50mm thick sand cushion under interlocking paver blocks , watered and consolidated, complete all as specified and as directed.
M&L for machine cut Kota stone slab, 20-25mm thick, as in flooring, set and jointed with neat cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab laid over 15mm thick screed bed in cement mortar 1:4 including rubbing and polishing over and including 50mm thick Plain cement concrete 1:2:4, type B1 using 20mm graded stone aggregate, as in sub base of floors including demolition of stone slab or tiles or pavers of any description in floors, aprons etc., laid bedded and pointed in any mortar complete all as specified and as directed.
M&L for machine cut Kota stone slab, 20-25mm thick, as in risers of steps, skirting, dado, cladding to pillars, etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including bull nosing the edges, rubbing and polishing complete including 10mm thick backing coat in CM 1:4 including demolition of stone slab or tiles or pavers of any description in floors, aprons etc., laid bedded and pointed in any mortar complete all as specified and as directed.
M&L for Glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm backing coat in CM 1:4 including roughening of existing wall surfaces all as specified and as directed.
M&L for point wiring 1.5 Sqmm single core PVC insulated FRLSH unsheathed 1100 volts grade copper conductor multi-stranded cables drawn through PVC casing capping of suitable size with all necessary fittings and provision of one run of PVC insulated FRLS unsheathed 1100 volts grade copper conductor multi-stranded single core cable of size 1.5 sqmm and connected to common earth dolly including provision of suitable size of modular metal surface box fixing in wall with and including white colour base and cover plates for mounting modular type switches, sockets, fan regulators, bell pushes etc. for one light point controlled by one switch 1 way complete one light point controled by one 1 way switch, including taking down carefully Aluminum/copper point wiring complete for light, fan, 5 A socket, 15 Amps socket, 2 way points and bell point etc in any type of wiring with boards, holders and any type of electrical fittings etc complete & making good to disturbed area all as specified and as directed.
All as described in item No. 53 but for one fan /exhaust point controlled by one switch and regulator all as specified and as directed.
All as described in item No. 53 but for one call bell point controlled by one bell push all as specified and as directed.
All as described in item No. 53 but for one 05 Amps socket outlet on independent board all as specified and as directed.
All as described in item No. 53 but for one 05 Amps socket outlet on the same board with other switches all as specified and as directed.
All as described in item No. 53 but wiring with 2.5 Sqmm PVC insulated unsheathed cable copper conductor multi stranded (for 15 Amps power socket) with one run of copper conductor PVC insulated multi-stranded cable 1.5 Sqmm for earth continuity conductor and connecting to common earth dolly, complete all as specified and as directed.
M&L for sub main wiring of any type and size and provision of new sub main wiring with 2 runs of single core PVC insulated unsheathed multi-stranded copper conductor cables of size 6 Sq mm drawn through and including PVC casing and capping of suitable size with all necessary fittings and provn of one run of 4 sqmm pvc insulated unshealted multistranded copper conductor single core for earth continuity and connected to common earth dolly ,complete all as specified and as directed Note :- 02 runs of 06 sqmm and 01 run of 4.0 sqm including 01 run of PVC casing capping will be measured as one length complete including taking down carefully sub main wiring of any type and size all as specified and as directed.
S&F modular switch piano type 6 Amps flush button 230 volts AC one way, complete all as specified and as directed.
S&F modular bell push flush type AC 230 Volts 6 Amps, complete all as specified and as directed.
S&F modular switch piano type 16 Amps flush button 230 volts AC one way, complete all as specified and as directed.
S&F modular socket outlet 6 Amps 2/3 pin combined flush type multipurpose 2 module, complete all as specified and as directed.
S&F modular socket outlet 6/16 Amps 2/3 pin combined flush type multipurpose 2 module, complete all as specified and as directed.
S&F modular fan regulator electronic step type 2 module suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed.
S&F in repairs or replacement of ceiling rose 3 terminal suitable for 230 volts AC supply, complete all as specified and as directed.
S&F in repairs call bell, ding dong, 230 volts AC supply all as specified and as directed.
S&F in repairs or replacement of LED lighting fixture with aluminium heat sink energy efficient 20 watt LED 6K fitting complete all as specified and as directed. Make : Havells Cat No Lumiline plus or eqvt in Crompton,Phillips, Bajaj, Wipro
S&F in repairs or replacement of LED lighting fixture with aluminium heat sink energy efficient 10 watt LED 6K fitting complete. Make : Havells Cat No Lumiline plus or eqvt in Crompton,Phillips, Bajaj, Wipro
S&F in repairs LED luminaire compromising of high brightness LEDs oval bulk head edge-lit LED luminaire 10W, complete with all accessories internally pre wired complete including provision of suitable size wooden board with sunmica top and connecting up light fitting with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector block complete aall as specified and as directed. Make: Havells HEXA or equivalent in CG/Phillips/Wipro
S&F in repairs or replacement of 2 ftx2ft LED panel for recessed dust-free installation with high brightness LEDs for glare-free homogenous illumination 34 watts incl electronic driver all as specified and as directed. Make Havells Venus Neo or eqvt in Phillips/Crompton/HPL
S&F in repairs or replacement of Integral LED 25 watts security light fitting comprising of pressure die cast aluminium housing with high power LEDs & electronic driver incl GI pipe med grade & bracket of suitable size fixed to pole /wall complete all as specified and as directed. Make: Havells ENDURA Pearl OR eqvt in Phillips /Crompton/CG/ Wipro
S&F in repairs or replacement of Celing fan 1200 mm sweep 3 blade energy saving 5 star rating including taking down existing un serviceable ceiling fan from the location and setting aside for fixing/ depositing to MES E/M store yard all as specified and as directed. Make Havells/Crompton/ Orient
S&F in repairs or replacement of exhaust fan, 250 mm sweep, 230 Volts, single phase, with necessary grouting and fixing arrangements and provision of 3 core flexible copper conductor cable of size 1.5sqmm size from ceiling rose to connector of exhaust fan all as specified as directed. Make: Havells Model - Ventil Air - DX White or eqvt in Crompton,Phillips.
M&L for 50mm bore GI tubes, medium grade as in supports for hanging ceiling fans of 1200/ 1400mm sweep, cut to required length, grouted into wall and making good distured surfaces as required all as specified and as directed.
M&L for down rods for ceiling fan, as per required length of 20 mm dia of medium grade duly threaded for check nut and holes drilled for split pin including mild steel bolts and nuts, double washers and rubber reel bush suitable for ceiling fans of 1200mm sweep fixed in repairs all as specified and as directed.
S&F in repairs three core flexible cords with multistranded copper conductor of size 0.50 sqmm,1100 volts grade from ceiling rose to connector block of ceiling fans/ exhaust fans all as specified and as directed.
S&F, in repairs, Sheet metal enclosure type TP&N Vertical Loadline DBs are fitted with Bus Bars, Neutral Links, Blanking Plates (without MCCB) 4 Way with double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and as directed.
S&F MCCB four pole 125 A breaking capacity 25KA 50HZ AC supply including dismantling old one, complete all as specified and as directed.
Supply and fixing factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plate with knockouts and suitable for one SPN MCB 32/40 Amps as incomer and 10 SP MCBs as outgoings complete all as specified and as directed Make - L&T / Legrand/ C&S/ Indo Asian / Standard .
S&F in repairs or replacement of MCB DP 32-40 A 10KA C series 50HZ AC supply incl dismantling old one, complete all as specified and as directed. Make: Indo Asian / Standard / Havells / L&T /Legrand / C&S
S&F in repairs or replacement of MCB SP 240 Volt of capacity 6 to 32 Amps‘C’ series, complete all as specified and as directed. Make: Indo Asian / Standard / Havells / L&T /Legrand / C&S
M&L for electrical earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground vertically, (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level, connected to GI wire 4mm dia (7.5 metre long) by means of bolts, nuts, washers made of galvanized iron connected to earthing to body of equipment. GI wire protected by 15mm dia light grade GI pipe (7.5 metre long) and watering arrangements with 20 mm dia GI pipe medium grade and GI funnel all as specified and shown in Electrical Plate No 3 of MES Schedule (SSR) Part I including necessary excavation and earth work in any type of soil, charcoal dust salt, and PCC 1:2:4 type B1 in chamber, RCC 1:2:4 type, B1 cover slab, 40mm thick with 6mm dia mild steel bars at 100mm centre to centre both ways and with 6mm dia MS hook complete, and testing of Earth resistance all as specified and as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings complete under trenches including all fittings including taking up or down steel tubing of 40 mm bore and connections of 40 mm dia size all as specified and as dircted.
Supply and lay pipe galvanized, “Medium class”, including fittings complete under trenches including all fittings including taking up or down steel tubing of 25 mm bore and connections of 40 mm dia size all as specified and as dircted.
Excavating in trenches n exc 1.5m wide and n exc 1.5m depth and getting out in any type of soil for laying cables, pipes, etc. all as specified and as directed.
Returning filling in including spreading leveling, watering and well ramming in layers n.exc 25cm thick all as specified and as directed.
Removing excavated materials to a distance n exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and as directed.
M&L for 1000 litres capacity rotational moulded polyethylene (HDPE) water storage tanks, 'ISI' marked, cylindrical, vertical with closed top conforming to IS 12701-1989 having two layers wall construction with manhole lid and suitable locking arrangement including making holes for inlet, outlet and over flow pipes, hoisted, fixed in position and testing complete including taking down of the existing RCC/PVC water storage tank of any description from the existing staging/ Bldg after disconnecting and dismantling of all existing pipe line connections carefully all as specified and as directed.
S&F for 25 mm dia PTMT ball valves high pressure (minimum weight 210 grams) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe all as specified and directed.
S&F for 25 mm bore gun metal gate valve heavy duty ISI marked with iron wheel head screwed both ends to iron pipes and fixed all as specified and as directed
S&F for 40 mm bore gun metal gate valve heavy duty ISI marked with iron wheel head screwed both ends to iron pipes and fixed all as specified and as directed
Supply and laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and as directed.
M&L for providing sand cushioning for protection of UG cable (8 cm deep before laying & 15 cm above the top edge of cable after laying) in trenches with dry (coarse) sand approved quality including filling, spreading and punning down to desired thickness complete all as specified & as directed. NOTE : Punned thickness of 18 cm only shall be considered for payment purpose.
Supply and laying sub class "B" bricks in trenches for protection of UG Cable with width equal to length of bricks, laid dry & flat complete all as specified & as directed.
S&F GI pipe light grade 50mm dia with all fittings & fixed complete on pole/walls/in road etc for cable protection all as specified and as directed.
M/S JAYDEEP CONSTRUCTION
SAGAR ENTERPRISES
OM INFRA
DHANSHRI ENTERPRISES
ASHIRWAD ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .