Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹21.2 L+₹4.6 L (27.4%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹22.2 L+₹5.5 L (33.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹24.0 L+₹7.3 L (44.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹26.6 L+₹9.9 L (59.5%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
RPRMAINT TO INTERNAL ELCTRFTN SYSTM CILNG FAN EXHAUST VENTILATION FANS OF DOMESTIC COMLX REPR OF OLD CONVENTIONAL FLAME PROOF LIGHT FITTING WITH ENERGY SAVING LED FLAME PROOF FITTING AT UNCHIBASSI UNDER GE (S) PATHANKOT
2022_MES_534341_1
GES/PKT/T-23/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹60,000
Yes
18 Aug 2022
28 Jun 2022
29 Jul 2022
28 Jun 2022
27 Jul 2022
13 Jul 2022
Amount
Taking down carefully point wiring of any type, size and description from hard/ teak wood batten/through pipes/casing capping (light, fan, sockets and socket outlets etc) including removal of battens, pipes, plug sockets, socket outlets, switches, shades, ceiling roses, light fittings etc. complete and making good the disturbed surface to match with existing all as directed by Engr-in-Charge.
Taking down main switches, distribution boards and cut outs etc. of any type and capacity along with the existing boards and removing the same from site and making good the disturbed surface/portion of walls all as directed by Engr-in-Charge.
Taking down carefully sub main wiring of any nos of wire and size with earth wire from wooden batten/surface conduit/casing caping complete with its all accessories
M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories on surface wiring with top cover of 03 mm thick plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. all as specified for the following :-
One light/fan point controlled by one, one way switch single pole.
One 3 pin 5 Amps socket point on the same board.
One 3 pin 5 Amps socket point on independent board.
One light point controlled by two,two way switch .
One buzzer/bell point controlled by one, one way bell push.
All as per item No. 9 above but point wiring with 2.5 sqmm cable and 1.5 sqmm earth continuity conductor for 3 pin / 5 pin 15 Amps socket and all as specified and directed.
M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FR type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia steel conduit 'medium grade' including all steel conduit accessories on surface wiring with top cover of ISI Marked plastic laminated sheet of 03 mm thick of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. all as specified for the following :-
One light/fan point controlled by one, one way switch single pole.
One 3 pin 5 Amps socket point on the same board.
One 3 pin 5 Amps socket point on independent board.
one Flame proof switch socket and plug combination in LM6 cable termination box in LM LM6, 16 Amp independent with cables 4 Sq mm
All as per item NO 14 above but point wiring with 2.5 sqmm cable and 1.5 sqmm earth continuity conductor for 3 pin / 5 pin 15 Amps socket and all as specified and directed.
S&F switch piano, single pole one way 5 Amps 240 Volt capacity flush type all as specified and directed.
S&F switch piano, single pole two way 5 Amps 240 Volt capacity flush type all as specified and directed.
S&F in repair electric bell ding dong type AC 230 volt 50 Hz single phase single pole all as specified and directed.
S&F Bell push flush type 5 Amps 240 Volt capacity all as specified and directed.
S&F Switch socket combination2 in 1 , 5 pin , 5 Amps flush type all as specified and directed.
S&F 3 pin 15Amps switch socket combination flush type multi purpose 2 in 1 type (3 pin 5 Amps and 15 Amps) all as specified.
S&F in repair stepped type electronic fan regulator flush type AC 230 volt suitable for any type of ceiling fan all as specified and directed.
S&F in repair Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F in repair, switch piano, single pole one way 5 Amps 240 Volt capacity flush type all as specified and directed.
S&F in repair Switch socket combination2 in 1 , 5 pin , 5 Amps flush type all as specified and directed.
S&F in repair 3 pin 15Amps switch socket combination flush type multi purpose 2 in 1 type (3 pin 5 Amps and 15 Amps) all as specified.
S&F in repair ceiling rose of size 65 x 50 mm surface bakelite 240 Volts three terminal as specified and directed.
S & F in repair wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED tube light, 4 feet, 20 Watt 220 V AC decorative type and connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED light, 2 feet, 10 Watt 220 V AC decorative type and connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED tube, T8, 20W, Ultra bright LED polycarbonate tube light with very high efficiency suited for installation in existing t8 fitting with G13 lamp holder complete all as specified and directed.
S & F in repair Environmental friendly, Ultra modern, energy saving, surface mounted, decorative oval bulk head edge - lit LED luminaire comprising of high brightness LEDs 10 Watt complete all as specified and directed.
Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings etc. including providioning of small pieces of electrical wire of size 1.5 sqmm to 10 sqmm single core and length not exceding 0.50 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed by Engineer-in-Charge (Note :- (i) any accessories found unserviceable that shall be replaced & paid under respective items of this Sch complete all as specified and directed .
Supply and fixing in repair LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as directed and specifed by Engr - in Charge
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH ®
Supply and draw sub main wiring in repairs of two run 4.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit medium duty and accessories of not less than 25 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 2.5 sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. (NOTE : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.) including making good disturbed surface all as specified and directed.
Supply and draw sub main wiring in repairs of two run 6.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit medium duty and accessories of not less than 25 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 4.0sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. (NOTE : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.) including making good disturbed surface all as specified and directed.
S & F in replacement existing unsv distribution board iron clad, with double door 4 way with IP-54,1K-09 protection,cemet spill prptector suitable for MCCB as incommer AC 415 Volts three pole with thermal release adjustable type (80% to 100 % ) and MCB as outgoing ,complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 63 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
Supply and fixing sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Single Pole & Neutral (SPN), suitable for 12 way, 240 volts, IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar, in proper position and takingdown old one all as directed by the Engineer-in-Charge.
Supply and fixing sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Single Pole & Neutral (SPN), suitable for 8 way, 240 volts, IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar, in proper position and takingdown old one all as directed by the Engineer-in-Charge.
Supply and fixing sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Single Pole & Neutral (SPN), suitable for 4 way, 240 volts, IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar, in proper position and takingdown old one all as directed by the Engineer-in-Charge.
Supply & fixing in repair MCB Single Pole and neutral (SPN) of capacity 6 to 40 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position all as directed by the Engineer-in-Charge.
Supply & fixing in repair MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position all as directed by the Engineer-in-Charge.
S & F in repair Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engr - in- charge
S&F Flame proof distribution board enclosure 8 way made out of galvanised steel sheet class EX II housed with flame proof MCBs of following capacities :- (a) MCB SPN 10 KA breakng capacity 32 Amps - 01 No (b) MCB SP 10 KA breaking capacity 6 Amps-06 Nos
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 4 core. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
(iv) MCCB 04 pole of 100 A current rating with rapturing capcity of 25KA, 415V, 50Hz, (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% complete all as specified
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep hard /dense type of soil getting out and levelling of bottom surface to required level for poles/stay assebly/cable all as specifed and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25m thick all as specified and directed.
Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point all as directed.
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
Supplying & Laying in trenches clear sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified.
S&F LED Lamp 230 volts,50 Hz,inverter LED 12/15 watt ,lumen 900 lm, rated current 0.045A, CRI less than 80, Charging time 8 to 10 Hours, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specififed and direccted.
S&F in replacement ceiling fan AC single phase 230/240 volts of size 1200 mm sweep complete type BEE 5 star rated VLDC rated complete with blade set ,down rod, copper wound fan motor , canopy set, shackle kit etc including connecting to ceiling rose with 3 core 0.5 sqmm flexible copper wire all as required or directed . Note: Old retrieved fans shall be deposited to MES store yard by contractor
S&F in repair Ventilation fan AC sinlge phase 230/240 volts of size 225 to 250 mm sweep PVC body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F in repair LED inverter street light 45W with RTC having luminium housing with clear toughened glass front coveer, IP 66 protection, operating voltage of 140V to 270V, having an efficiency of upto 02 hrs backup, reserve polarity protection , hight voltage cut off at 300V+- 10V and 5 KV internal surge protection with a power factor greater than 0.95 complete making connection and testing complete all as directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1200mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
Replacement of old unserviceable gun metal bush of ceiling fan complete all as spd and directed.
Replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd ISI marked complete all as spd.
All as per Srl item above but 3.15mfd complete all as spd.
Replacement of old unserviceable ball bearing suitable for 1200/1400 mm sweep complete. Make NBC/SKF (bearing with 8 balls shall only be used) complete all as spd.
Replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/ 1400mm sweep complete all as specified and directed.
Replacement of old unserviceable fan blades, ISI Marked, suitable for 1200/1400mm sweep ceiling fan of any make complete all as spd.
Repalcement of old unserviceable MS down rod of appropriate External dia of ceiling fan complete (length of rod not less than 45cm and not more than 60cm and 15 mm dia) complete all as spd.
S & F Canopy for ceiling fan as per existing sample complete all as specified and as directed.
Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/ oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed by Engr-in-Charge. (Unserviceable parts if any will be measured and paid seperately).
Supply and Fix cable PVC insulated and overall sheathed with flexible copper conductor Single core of size 1.0 sqmm complete all as specified and directed.
Dismantling and Re-winding of exhaust fan/ industrial wall mounting fan/pedstral fan motor 250-300 mm sweep any make of fan with super enameled copper winding wire of suitable gauge as per existing including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections fan complete all as spd and directed (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used).(ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
All as per Srl item 72 above but 350mm-450mm sweep complete all as spd and directed..
S & F louver, suitable for exhaust fan of any make and size upto 300 mm, fixed in repair complete all as specified and as directed.
All as per items 74 above but of size 400 mm
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to ceiling fan 1200-1400mm sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to exhaust fan/wall mounting fan/Padestial Fan of any sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
Disconnecting, dismentling and taking down carefully single pointed air termination alumn rod incl GI pipe any size incl nuts & bolts and seggregating U/S or serviceable parts incl removing from site or setting aside for reuse.
Disconnecting, dismentling and taking down carefully aluminium strip any size upto 32 x 6 mm complete with saddles GI tubing insulators ad seggregating U/S or serviceable parts incl removing from site or setting aside for reuse.
Disconnecting, dismentling and taking down carefully GI strip of any size up to 32 x 6 mm and seggregating U/S or serviceable parts incl removing from site or setting aside for reuse.
Supply and fix single pointed air termination alum rod 12 mm dia 300 mm long incl insulator, nuts & bolts for fixing air termination rod to pole pipe all as required at site.
Supply and fix in repair copper strip 20 x 3.15 mm complete incl providing nuts, bolts & saddle/Insulators made out of porcelain or fibre for roof conductor/down conductor incl welding or brazing /nut bolts for joints all as required at site or directed by engr-in-charge.
Supply and fix in repair GI strip 32 x 6 mm, buried in ground upto 50 cm depth or fixed to wall with nuts, bolts & saddles/ insulators etc for loop earthing incl welding / nut bolts for joints all as required at site or directed by engr-In-Charge. (Note ; earth work will not be paid seperately)
Supply and fix Aluminium strip 35 x 3.15 mm, buried in ground upto 50 cm depth or fixed to wall with nuts, bolts & saddles/insulators etc for loop earthing incl welding / nut bolts for joints all as required at site or directed by engr-In-Charge. (Note ; earth work will not be paid seperately)
Supply and fixing in repair porcelain vitreous white/ brown/ green spacers insulator of size 75mmx35mmx40mm height complete with one number galvanized iron stud bolts 6mm dia x 40mm long including nut & washers and two number galvanized iron fixing bolts of size 6mm dia and 50 mm long including washers and drilling holes for holding /foxomg aluminium strip/roof conductor as required including taking down the broken insulator complete all as specified and as directed.
Dismentling and taking down old unserviceable earthing any type incl removing from site.
Supply and fixing in repair GI Pipe medium grade 15 mm bore for for fixing of ATR complete.
M & L for pre cast cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate for earth pits as mass concrete.
Material and labour earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty chemical for earthing all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing). and dismantling old defective earthpit.
M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with galvanised iron strip 32x6 mm including dismantling old one. .
M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 4mm dia galvanised iron or steel wire including dismantling old one.
Supply and lay 40 mm dia GI tubes medium grade galvanised with all fittings laid in trenches etc for protection of cable of following sizes:-
All as per Srl Item No. 92 but for 15 mm dia bore
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Supply and fixing in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws including provision of 30 cmx25cmx8cm sheet metal box made out of 3.15 m thick CRCA sheet with front hinged door shutter & locking arrangement and duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
Disconnecting the inlet/ outlet water connections and electric connections of Storage type electric water heater of capacity 50/25 Ltrs capacity, taking down carefully from wall after unscrewing nut/bolts ,checking the outer body for any cracks and strip opening the same carefully for thorough inspection of serviceablity/functionality of parts such as internal tank, syphon assembly, thermostat switch, heating element, glass wool etc, servicing complete and re-assembling and re-fixing after repair,fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacemeny shall be measured and paid under relevant Schedule items of Sch here-in-after.
Supply only internal SS tank of storage type electric water heater of 25 ltr capacity complete with syphon –assembly, 1.5 KW/2.0 KW element , rubber gasket , thermostat switch , all as specified and directed for carrying out repairs under relevant item No.97 . Note :- The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor . Tank with stud type round element shall only be used . (Triangular element shall not be allowed .)
Supply only syphon assembly made out of SS of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as spd and directed for carrying out repairs under relevant item No.97.
Supply only thermostat switch ISI marked for storage type electric water heater AC 230 volt adjustable range from 0-90 degree Celsius ) for carrying out repairs under relevant item No.1
Supply only cup type storage type electric water heater element AC 230 volt, of rating 1500/2000 watt for carrying out repairs under relevant item No.97.
Supply only triangular type storage type electric water heater element AC 230 volt, of rating 1500/2000 watt for carrying out repairs under relevant item No.97
Supply only outer body suitable for 25 ltr storage type electric water heater made out of MS sheet factory made complete with fixing bracket matching with existing complete all as specified and directed for carrying out repairs under relevant item No.97.
Supply only glass wool of 25 ltrs capacity storage type electric water heater complete all as specified and directed for carrying out repairs under relevant item No.97.
Supply only indicator lamp square/round type suitable for storage type electric water heater 25/50 ltr all as per sample AC 230 Volt for carrying out repairs under relevant item No.97.
Supply and replacement cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 70/.0076mm.
Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
De-scaling of storage type electric water heater of capacity 25/50 ltr after taking down the storage type electric water heater from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation of storage type electric water heater complete all as directed by Engineer-in –Charge.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked all as specified and as directed.
Replacement of spring loaded air release valve ISI marked suitable for 25 and 50 ltrs capacity storage type electric water heaters.
Replacement of safety valve / dead wt. valve ISI marked suitable for 25, and 50 Ltrs capacity storage type electric water heaters.
Supply and replace pillar taps, cast copper alloy with capastan heads, chromium plated, screwed down high pressure with lettered ‘Hot or Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed fancy type of size 15 mm .
Supply and fix gun metal glove or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm.
Supply and fixing anchor bolt 12mmX100mm long complete all as spd and directed (Note:- Anchor bolt shall be grouted with hammer drill only)
Preparing the old surface by rubbing/scratching the old paint and providing the two coats of synthetic enameled paint through spray paining of 25 ltr storage type electric water heater.
Supply and replace brass non return valve suitable for 25/50 ltr storage type electric water heater of size 15 mm.
Supply and replace bottom cover plate of storage type electric water heater of capacity 25/50 ltr complete with MS screw all as per sample.
Dismantling of Insulated hot water storage tank of capacity 200/300/500 Ltrs connected Solar Evacuated collectors/flat collectors and cold water tank with GI fittings & PVC pipe connection. Servicing,Testing, Commissioning & descaling of Hot water storage tank removing of corrosion/dust, replacement of UNSV PVC pipe after re-fixing the same.
Service and descaling of Solar Evacuated tube Collector/ Flat collectors with sulphuric acid by forcefully injecting the hot chemical into collector for number of times to clean the Solar Solar Evacuated tube Collector/Flat Plate Collector and assembled the same.
S & F in replacement of Evacuated tube collector for Solar Water Heater of capacity 300 LPD of suitabale size as per sample approved by Engineer -in-charge on the gound.
S & F in replacement of Evacuated tube collector for Solar Water Heater of capacity 500 LPD of suitabale size as per sample approved by Engineer -in-charge on the gound.
Replacement of heating element 2/3 KW suitable for stand by back up supply to solar water heater.
M & L for replacement of unserviceable stop valves and S & F stop valves , cast copper allow, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or fixed Size 15mm ISI mark.
Supply only wiring for desert cooler including all accessories all complete diected for carrying out repairs under relevant item.
Supply only blower motor of single way shaft 240 Volts 50 c/s of suitable capacity for desert cooler of capacity 3000 CFM to 5000 CFM single way shaft 240 Volts 50 c/s complete all as specified and directed for carrying out repairs under relevant item.
Supply only water circulation pump suitable for desert cooler of capacity 3000 CFM to 5000 CFM 240 volts 50 c/s single phase complete all as specified and directed for carrying out repairs under relevant item.
Supply only Khaskhas pad honey bee type (set of 3) for Desert Cooler of any capacity ( Set of three) complete all as specified and directed for carrying out repairs under relevant item.
Removing the old paint from the body of desert cooler making the body dust proof and preparing the surface and painting the desert cooler with 2 coats of synthetic enamel paint of superior quality over a coat of Red Oxide primer all as specified.
Material and labour in replacement of Fan blade hub assly only for Blower motor of desert cooler made of alloy/Forged steel suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
Material and labour in replacement of water distributor and PVC pipe connection for water connection of desert cooler 3 piece (length not less than 35 cm each piece) (As per sample) suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
Material and labour in replacement of Capacitor of capacity 4mfd suitable for desert cooler complete all as specified and directed
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/S BR ENTERPRISES
P S BUILDERS
R K ENTERPRISES
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .