Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC DHAWANA ROAD REWARI HARYANA | ₹29.6 L Quoted ₹29.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹35.4 L+₹5.5 L (18.4%)Rejected-AOC | ₹35.4 L+₹5.5 L (18.4%) | L2 | Rejected-AOC L2 |
| 3 | Not Admitted-Fee/PreQual/Technical WARD NO 17 NEAR JEEVAN JYOTI PUBLIC SCHOOL VPO NARYANA 132103 | NARYANA | PANIPAT | HARYANA | 132103 | - | - | Not Admitted-Fee/PreQual/Technical Others-Proper documents not submitted |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Proper documents not submitted |
Tender Value
₹24.7 L
EMD Value
₹49,400
Closing Date
5 Nov 2024, 5:00 pmClosed
KULJEET
MICAD Divsion Faridabad
As over flowing pond in villages pond has become a big problem in several villages of Haryana State Haryana Pond and Waste Water Management Authority has identified 1450 Ponds scattered at various Districts of Haryana to develop these ponds, pond aut
2024_HBC_408240_1
20240DCD7803 6E74 4D35 98C4 4A8AEBED606B1959CAD
Open Tender
Civil Works
Works
200 days
CHIRWARI
MICADA Work
2 documents required · 2 mandatory
₹1,000
₹49,400
Yes
20 Mar 2025
30 Oct 2024
6 Nov 2024
30 Oct 2024
5 Nov 2024
30 Oct 2024
Amount
Galvanizes steel chain link both end twisted fence fabric having opening size 7.5x7.5 cm and 3.15 mm dia wire, 2.2 meter height of mesh, with 2.8 meter ht of MS Angle 50x50x5 mm supports fixing at spacing of 3 meter centre to centre, supports with MS Flat 35x5 mm. Fencing supported with MS Angle 35x35x5 at top and bottom. The M.S Angle supports shall be anchored in cement concrete (1:3:6) blocks 45x45x60 cm additional razor barbed wire fencing shall be provided at the top of mesh, fencing including gate @ Rs 2000/- per meter (N.S. Item)
Horizontal directional drilling with micro tunnelling methods, for pipe laying under pucca rasta /road crossing (N.S.Item)
Providing and fixing 12 Watt LED Street Lighting of 75 watt solar panel, 12.8 volt 30 Ah Lithium Ferro Phosphate battery, 12 Watt White LED Luminaire and Pole of 5 Meter above ground level with dusk to dawn operation {first 4 hours full light Systemding, fixing and testing of Solar light including battery: min. 24 lux) , rest of the time at lower light (50% Min. 12 lux) level} and 3 days or minimum 36 operating hours autonomy or as per direction of engineer-in-charge
Providing fixing of Header Assembly/Manifold 3` to connect the filtration unit (loose) (Rate app. By worthy Administrator)
Pro. and Fix. Tank Type (Make of Metal) Fertilizer and Chemical injector System confirming to IS 14483 (Part 3) of 2018 for demonstration and guiding the farmers regarding fertilization and Chemicalisation of System (rates including ventury with manifold 1.0” = 1300 and 60 liter fertilizer tank=4400) rate approved by Worthy Administrator MICADA, Haryana.
Providing, fixing, testing and commissioning of pressure gauge 2” dial with Glycerin filled (NS Item)
Supplying, erection, testing and commissioning of Solar AC Openwell Submersible Pump Set with three phase motor having casingof Alloy Steel for the required power capacity, discharge and Head including all PVC insulated polymer sheathed 3 core flat type cablingin conduit, required from solar plant to solar pump through control room( Rates approved minutes of meeting of 6th tender allotment commitee under the chairmanship of Engineer-in-chief cum Administratror MICADA) AC Submersible pump set of power capacity 10 HP.
Providing, lowering, laying, aligning, fixing in position and jointing (with medium bodied cement solvent) at all level/ depths of TypeB, Class-2 (4 Kg/cm2)UPVC pipes for water supplies as per IS code 4985 : 2021 (amended up to date) in trenches in complete including cost of Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per directionof Engineer. Rate includes cost of all specials like bends , tees required during laying of pipe line along required alignment. UPvc Pipe 140 mm dia.
Providing and lowering of HDPE floater manufactured with 225 mm dia PE pipe having PE-80 and PN-10 to float the submersible open well pump/motor (NS item)
`Supply Installation testing commissioning of Solar Photovoltaic Stand alone Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength. Including lightning and surge voltage protection, Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required, built in metering system to moniter plant performence (Amp-meter, Volt-meter, Frequency meter, Energy meter, Watt-meter, and other instrument/equipment as required) Note:- PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Mono Crystalline Silicon Solar Cell Modules IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-1- requirements for construction and Part 2 – requirements for testing, for safety qualification or quivalent IS and be mounted on fixed Aluminium/GI structure of adequate strength and design as per IEC/IS specification. Including field-based electroluminescence (EL) study be performed after receiving the modules at site and after installation. Module mounting structure (MMS) design and drawing shall be duly vetted from government institute Including third party inspection Actual parameters/capacity will be finalized after approval of design and drawing. (N.S. Item)`non schedule
Construction of 6`x6` regulation hut constructed with 9` thick brick masonary inner side covered with 1.25 mm thick class-1 GI corrugated sheets (with 750 gm Zinc coating per sqm on its both sides) provided with proper door and windows as per approved design and drawing inner size 6`x6` Av. Height 8` covered with Precoated G.I. Corrugated sheet ( Non Scheduled item )
Hydrant assembly for Nakka in fields, Rates are including rates of Tee, riser pipe, butterfly valve, Flange and labour for fixing butter fly valve should be as per IS 13095-2020
Supply and jointing of 110 mm 6 Kg/cm2 HDPE pipe (for jointing floater, all filters, PRV etc)
Supplying, erection, testing and commissioning of Variable Frequency Drive (VFD) complete with all accessories for the required power capacity of Solar Pump, VFD Drive for Pump set of power capacity 10 HP
Complete operation and Maintenance and watch and ward of the project for one year including operation of pump, pipe line, accessories, electromechanical, solar plants complet in all respect of pump house, pipe line and accessories, electromechanical, solar plant etc complete in all respect for per month upto one year
Providing, lowering, laying, aligning, fixing in position and jointing (with medium bodied cement solvent) at all level/ depths of TypeB, Class-2 (4 Kg/cm2)UPVC pipes for water supplies as per IS code 4985 : 2021 (amended up to date) in trenches in complete including cost of Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per directionof Engineer. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. UPvc Pipe 110 mm dia.
Bidder Name
Amount
A K ENTERPRISES (GSTN-NA) BID ID -1163130
M/s PRB Construction (GSTN-NA) BID ID -1163225
M/s PRB Construction (BID ID -1163225)
M/s PRB Construction (BID ID -1163225)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .