Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.1 LAccepted-AOC | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹33.3 L+₹2.8 L (9.28%)Rejected-Finance | L-2 | Rejected-Finance Not Being L1 | |
| 3 | L-3₹33.5 L+₹3.0 L (9.96%)Rejected-Finance AKULA STREET BHAPUR BAZAR BERHAMPUR DISTT GANJAM ODISHA 760001 | GANJAM | ODISHA | 760001 | L-3 | Rejected-Finance Not Being L1 | |
| 4 | L-4₹33.5 L+₹3.1 L (10.1%)Rejected-Finance | L-4 | Rejected-Finance Not Being L1 | |
| 5 | L-5₹33.7 L+₹3.2 L (10.4%)Rejected-Finance | L-5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
26 Apr 2024, 6:00 pmClosed
GARRISON ENGINEER (I) GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR MAINTENANCE TO CHAIN LINK FENCING COMPOUND WALL DRAIN AND ATTENDING DAY TO DAY COMPLAINT OF LT HT BREAKDOWNS UNDER GE I GOPALPUR ON SEA
2024_MES_648467_1
8000/126/2023-24/1025/E8
Open Tender
Civil Works
Item Rate
180 days
GOS
As per Tender Documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER (I) GOS
₹60,000
18 Apr 2025
30 Mar 2024
27 Apr 2024
30 Mar 2024
26 Apr 2024
20 Apr 2024
Amount
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for. Complete all as specified & directed.
S&F machine pressed precast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment complete all as specified & directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed.
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in path/ hard standing surface finished even and fair complete all as specified and directed.
M&L 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in sub base,floor , plinth protection etc and finishing cement concrete even and fair specified and directed by Engr - in - Charge.
M&L Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and directed.
M&L for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth in soft /loose soil etc complete all as specified and directed.
M&L for Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed
M&L for Removing excavated material (Soil) exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
M&L for providing Glass strip of 6 mm thick and 40 mm deep in hardstanding for making panels complete all as specified and directed.
M&L for 10 mm thick heavy duty exterior designer tiles of size 300 mm x 300 mm as in floor set, jointed in neat cement slurry and pointed with grey cement and pigment complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed.
M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for finishing cement concrete even and smooth using extra cement complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for preparing new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed
Dismantling posts or sturts (wood,steel or RCC) any section incl taking out embedded portion and making good disturbed ground etc all as specified and directed.
Dismantling fencing wire mesh any type etc all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out making good the disturbed surface if required in soft/ loose soil complete all as specified and directed.
M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete all as specified and directed.
S&F Angle iron posts and rails,drilled and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc, flat iron fillets (for secruing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165.
Mild Screw bolts (Machine made) with hexagonal or square head at one ends and to fitted with washers and one hexagonal or square n.exc 15cm long, dia of neck 11 to 15mm all as specified and directed by Engr-in-Charge.
S&F PVC coated chain link of 3.16mm dia mild steel galvanised fencing of mesh size 100 mmx 100 mm as per IS : 2721-2003 weight n exc 4.00 kg per sqm complete all as specified and directed by Engr - in - Charge.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified & directed.
M&L for Removing of sludge from septic tanks including removal of sludge water manually or mechanically in all respect and removing the sludge to distance not exceeding 500 mtrs and burried in to the ground and making to a true surface and covering with loose soil and as directed (The rate included excavation and filling ).
M&L for Cleaning of sewage line (length from manhole to manholes) of any dia by roding and flushing after cleaning and removing mud/sludge etc to a distance exc. 250m but n.exc 500m and spreading in low laying areas and covering with loose soil and as directed.
M&L for Cleaning of manholes and removing sludge from manholes of any size and depth and deposing the sludge and spreading in low laying areas and covering with loose soil and as directed.
M&L for Cleaning the blockage of floor trap, nahani trap, gully trap and first man hole and removing sludge from the site and depositing the sludge at low area etc complete all as specified and directed.
M&L for Dewatering of soak well by diesel driven pump & motar collecting the liquid in closed sewage tank and depositing the same to an isloted place at a distance n exc 5 km. (Note :- diesel/pump/motar and pipe/section and delivery and sewage tank arrange by contractor and the cost of the same shall be deemed incl in quoted rate) etc complete all as specified and directed. (Note : Max Qty for one trip = 3KL)
M&L for cutting and removing wild bushes/ vegetation, surface dressing around the septic tank/sock well/ manholes to a distance of 2 mtrs all around and depositing surplus spoil/ rubbish n.exc 50 m complete all as specified and directed.
M&L for cutting and removing wild bushes/ vegetation, etc at bldgs above the 2m height from GL and depositing surplus spoil/ rubbish exc 100M but n.exc 500 M complete all as specified and directed.
M&L for Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 150 mm internal dia of pipe com plete all as specified and directed.
M&L for Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 200 mm internal dia of pipe complete all as specified and directed.
M&L for salt glazed stoneware (SGSW) drain pipes laid in trenches of 150 mm internal diameter of pipe and jointed in CM 1:1 complete all as specified and directed.
M&L for salt glazed stoneware (SGSW) drain pipes laid in trenches of 200 mm internal diameter of pipe and jointed in CM 1:1 complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 200 mm internal dia of pipe complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 200 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and directed.
M&L in repairs salt glazed stone ware gully traps size 150 x 150mm, square or round mouthed, type ‘P’ including setting and jointing to drains with CM 1:1 including demolition of existing traps complete all as specified and directed. (Note: CI grating will be meaured separately).
S&F Mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,frame work of watertanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening anf fixing complete all as specified and directed.
M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc all as specified and directed by Engr - in - Charge.
M&L preparation of new steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
Dismantling posts or sturts (wood,steel or RCC) any section incl taking out embedded portion and making good disturbed ground etc all as specified and directed.
Dismantling fencing wire mesh any type etc all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out making good the disturbed surface if required in soft/ loose soil complete all as specified and directed.
M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete all as specified and directed.
S&F Angle iron posts and rails,drilled and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc, flat iron fillets (for secruing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165.
Mild screw bolts (Machine made) with hexagonal or square head at one ends and to fitted with washers and one hexagonal or square n.exc 15cm long, dia of neck 11 to 15mm all as specified and directed by Engr-in-Charge.
S&F PVC coated chain link of 3.16mm dia mild steel galvanised fencing of mesh size 75 mmx 75mm as per IS : 2721-2003 weight n exc 4.00 kg per sqm complete all as specified and directed by Engr - in - Charge.
S&F Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified & directed.
M&L for preparation of old painted surfaces and applying one coat of synthetic enamel paint in concrete surface complete all as specified and directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 cm high etc complete all as specified and as directed by Engineer-in-Charge. (Note : Rates to be deemed fit for all security measures while working in heights more than 6m from GL).
S&F in repairs Galavinised 2 strand steel barbed wire 2.24 mm dia barbed wire with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts including securing tying at crossing with and provision of galavanised mild steel wire staples pins etc as directed (each line wire to be measured) all as specified and directed.
Taking down rain water pipe of any size or pattern incl all fitting head,shoe,band,swan neck etc complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F PVC stack clamps to walls or roof for 75 mm bore of pipe etc complete all as specified and directed.
S&F PVC stack clamps to walls or roof for 100 mm bore of pipe etc complete all as specified and directed.
S&F in repair 75mm PVC (SWR) floor trap, plain with grating,jointing with solvent cement as per site requrement all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and directed
M&L for Removing Demolished material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
M&L for Cleaning the concerned RCC surface by means of wire brush to expose the concrete surface which should be free from all loose particles, dust, laitance, etc complete all as specified and directed.
M&L for Making corner fillets with Polymer modified cementitious (PMC) mortar (PMC:C:M :: 1:2:4 by weight) at all joints of horizontal and vertical surface and doing bore packing with PMC mortar complete all as specified and directed.
M&L for the joints of pipes and concrete/masonry are to be sealed with epoxy putty or epoxy mortar (PMC:C :: 1:2 by weight) and the same is semi-rounded upto 5mm above surface level all along the periphery of PVC pipes complete all as specified and directed.
M&L for application of one coat of Acrylic Polymer Modified Cementitious (APMC) slurry (APMC:C :: 1:2 by weight) coating over the RCC slab surface and carried upto finished floor level on vertical portion (walls) complete all as specified and directed. (Note : This coat is allowed to get dry for 4-6 hours.)
M&L for application of one coat of Acrylic Polymer Modified Cementitious topping rendering (APMC:C:M :: 1:2:2) 1-1.5mm thick over the first coat Acrylic Polymer Modified Cementitious complete all as specified and directed. (Note : This coat is cured for 48 hours.)
M&L for rendering 15mm thick in CM 1:4 on brick or concrete surface, finishing even and smooth using extra cement incl Integral Waterproofing Compound (0.2 % or 100 ml per bag of cement) complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded brick coarse aggregate as in sunken floors etc all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off premises complete all as specified and directed
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
S&F in repair CP grating 100 mm dia with waste hole (minimum weight 40 gm) complete all as specified and directed
S & F in repair CP Jet spray for 15 mm bore all as specified and directed.
M&L in repairs for vitreous china wash basin, white,flat back, size 550 x 400 mm including supply & fixing of brass chromium plated coupling 32 mm etc complete all as specified and directed.
M&L in repairs vitreous china squatting pan , ‘Orissa’ Pattern, size 580 X 440 mm white, with integral foot rests etc. complete all as specified and directed.
M&L in repair Wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe excluding flushing cistern and flush pipe complete all as specified and directed.
S&F in repairs Plastic water closet seat cover, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
M&L for Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 300 mm to 450 mm internal dia of pipe complete all as specified and directed.
S&F reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 300mm dia as in repair complete all as specified and directed.
S&F reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 450mm dia as in repair complete all as specified and directed.
M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 250 ltr n.exc 500 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using bleaching powder @ 0.25 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 500 ltr n.exc 1000 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using with bleaching powder @ 0.50 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed
S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for add or deduct for each 25mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L Random rubble masonry walling well bonded, bedded, solidly hearted, uncoursed built in CM 1:6.Complete all as specified and directed.
M&L for rendering 20 mm thick in CM 1:6 on stone masonary surface, finishing even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L for attending day to day breakdown complaints of any nature in low tension line after receiving the complaint from complaint cell/ JE concerned and rectifying the same as soon as possible by checking the LT panel, MCCB, cable from the source to the end by meggering the cable or any means complete all as specified and directed. This work includes all minor repairs i.e Note : If any major materials are used will be measured and paid separately in appropriate items below
M&L for attending day to day breakdown complaints of any nature in high tension line after receiving complaint from complaint cell/ JE concerened and rectifying the same as soon as possibble by checking the VCBs, RMUs, Cables, Four pole/ Two pole structures from source to the end by meggering the cable or any means complete all as specified and directed. Note : If any major materials are used will be measured and paid separately in appropriate items below.
Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified
Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified.
Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified
Supply and laying double wall corrugated HDPE pipe 50mm outer dia for protection of UG cable complete all as specified
M&L PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for filling of pole & stay complete all as directed
M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling of pole & stay complete all as directed
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for copining of pole complete all as directed
M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 50 mm bore including removing the rusted old one complete all as specified and directed.
M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 80 mm bore including removing the rusted old one complete all as specified and directed.
M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 100 mm bore including removing the rusted old one complete all as specified and directed.
Taking out old unserviceable PCC/steel tubular pole 9 mtrs long and supply and fixing steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed.
Taing out old usserviceable PCC pole of any size and supply and fixing in repairs Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of weather proof paint complete, all as specified and directed.
S & F in replacement of Cross arm, bracings, supports , clamps and back plate fabricated from structural steel section, including nut , bolts , washers, welding , bendings cold or hot, drilling hole for both in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of paint incl taking down the old unserviceable cross arms complete all as directed.
Taking out old UNSV and Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for the sizes '10 Sqmm 2 Core.' including taking down old, complete, all as specified and directed.
All as per item No. 129 above, but10 Sqmm 4 Core.
All as per item No. 129 above, but 16 Sqmm 4 Core.
All as per item No. 129 above, but 25 Sqmm 3.5 Core.
All as per item No. 129 above, but 35 Sqmm 3.5 Core
All as per item No. 129 above, but 50 Sqmm 3.5 Core
All as per item No. 129 above, but 70 Sqmm 3.5 Core
All as per item No. 129 above, but 95 Sqmm 3.5 Core
M/L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge.
Supply and fixing of moulded case circuit breaker Four pole 100/63Amps 16 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.
Supply and fixing of moulded case circuit breaker Four pole 160 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge
Supply and fixing of moulded case circuit breaker Four pole 200 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge
Supply and fixing of moulded case circuit breaker Four pole 250 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.
Supply and fixing of moulded case circuit breaker Four pole 320 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.
Supply and fixing of moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.
Supply and fixing of moulded case circuit breaker Four pole 630 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge.
Supply and fixing of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of LT current transformer ratio from 200/5 Amps or 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete all as specified and directed. Make : L&T.
Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete all as specified and directed.
M&L for painting to LT panels of any size with two coats of sky blue paint over a coat of red oxide primer outerside and two coats of off white paint over a coat of red oxide primer internally complete all as specified and directed by Engr- in-Charge. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE. 2. While painting of the panels protection of MCCB's and MCB's to be taken care of by the contractor. Any damage occured during the painting will be bear by the contractor.
S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 2 core XLPE armoured aluminium conductor cable of size 6-16 sqmm complete
S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16-50 sqmm complete
S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete
S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm complete
Boring of holes horizontally for laying of 80mm dia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed.
Supply and fixing Aluminium tube terminal/ lugs for the size of 10 to 25 Sqmm under mentioned size complete
All as per item No. 156 above, but 35 to 50 Sqmm
All as per item No. 156 above, but 70 to 120 Sqmm
All as per item No. 156 above, but 150 to 185 Sqmm
Supply, fabricate, erect, test and commission in replacement outdoor LT Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made standard design as per electrical requirements to suit power distr sys , enclosure fabricated out of 3.00 mm thick MS sheet with front and back done openable, excavation and earth work, PCC foundation etc,with hinged doors and lcoking arrangemetn , air vents, tappered roof, incoming and outgoing cable connections from bottom with compressed cable gland etc as required with and including the following, supplied fitted and connected internally complete 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 400 Amps and neutral rating 200 Amps mounted on non cracting resin type insulators, moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In complete all as specified
S & F in replacement of old UNSV. Cable loop box with SMC Junction box shock and rust proof , rot/termite resistance, tamper proof, with necessary pole mounting arrangements FR type ( (270mm x 225mm x 135mm) with in-built /housed terminal for 04 pole wire termination and 6AMCB din-rail mounted , hinged door with locking arrangements incl necessary Galvanised iron clamps, bolts/nuts suitable to hold/accommodate to the exisitng pole(any type)/ bldg etc by removing the exisiting electrical connections and reconnecting back the same cable complete all as specified & directed Make: Sintex/Hensel (Note : any glands/lugs/lock-pads reqd for the same is within the the rates quoted)
Supply and fixing MCB SPN 32 amp rating 240V, 10KA 'C' curve and current carrying capacity complete with connection testing and commissioning.
Supply and fixing MCB TPN 63 amp rating 240V, 10KA 'C' curve and current carrying capacity complete with connection testing and commissioning.
Supply and fixing connectors of two pole/three pole/ fourpole complete all as specified and directed
S & F in repairs Disc type porcelain vitreous, brown or white insulator suitable for 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete all as directed.
S & F in repairs Pin type porcelain vitreous,brown of white insulator suitable for 11KV HT of working pressure of size 150mm height, 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as directed.
S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. (Make : 3M/Birla/Denson)
Supply & Lay , testing and commissioning in repairs XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas complete
Repairing / Servicing the Air break isolating switch HT 33 KV/11 KV 200/400 Amps by replacing the defective major spares including provn of minor bolts nuts etc all as specified. Note :- Major spare will be measured & paid seperately under relevant item of Sch'A' item No. 27
Supply only 33 KV/11 Airbreak switch spares "Male contact/moving Contact Blade" all as directed.
All as per item No. 175 above, but Female contact/Fix Contact Jaw
All as per item No. 175 above, but Rotating contactor pipe 200A/400 A
All as per item No. 175 above, but MS jumper carrier
All as per item No. 175 above, but Back Connector plate
Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration in distribution 11 KV transformer /Distribution transformer 63 to 650 KVA or for replacement complete including removing of old unservicable transformer oil all as specified and directed.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 63 KVA to 315 KVA transformer.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA to 650 KVA transformer.
Supply and fixing of fuse wire tinned copper of different capacity as per ground requirement complete all as specified and directed..
M&L for cable fault locator vehicle mounted to locate fault at any type of location with one fault locate at a time complete all as specified and directed by Engr-in-Charge
M&L for in repairs aluminium conductor steel reinforced complete all as specified and directed to be used as jumpers
M & L for Cutting and trimming of tree branches 5 mtr all around of any size which is coming over the two/four pole structure of 11 KV line by using required tools and plants incl removing trimmed tree branches. (Note : Each cleaning will be measured and paid separetely)
S & F in repair horn gap fuse 11 kv (Polymer) 200 Amps horizontal/vertical type for outdoor use including all connected accessorises complete all as specified and as directed
S & F in repair horn gap fuse 33 kv (Polymer) 200 Amps horizontal/vertical type for outdoor use including all connected accessorises complete all as specified and as directed
S&F in repair 33 KV disc insulator polymer type with hardware fittings complete all as specfied and directed
S&F in repairs power aluminium bolted type connectors to be fixed on jumpers/aluminum conductors/AB conductors of any size complete all as specified and directed
S&F in repairs of AB conductor of size 100 Sqmm with colour code (RYB) as required on ground for MRS structure complete all as specified and directed
S&F in repairs of 33 KV post insulators complete all as specfied and directed
S&F in repairs of 11 KV post insualtors complete all as specified and directed
M/s Bapujee Builders and Traders
Likitha Enterprises
M/s TECH TEAM
M/S S. N. ENTERPRISES
M/s Ats Electricals
R K Traders
V.Venkata Ramaiah
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .