Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹39.9 L+₹2.1 L (5.56%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹39.9 L+₹2.2 L (5.72%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹40.0 L+₹2.2 L (5.83%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹40.1 L+₹2.3 L (6.16%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
23 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Provision of certain sanction works (01) in the area of AGE B/R I under GE (N) Ahmednagar
2021_MES_417157_1
8496 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹89,000
Yes
9 Mar 2021
30 Jan 2021
25 Feb 2021
30 Jan 2021
23 Feb 2021
18 Feb 2021
60 days
Amount
Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortor etc complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site etc complete all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge
Dismantling of false ceiling boards (fibre, pulp, insulation, etc,) or any type ceiling board any thickness including cover fittets etc complete all as specified and directed by Engineer-in-Charge
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets partly in roof coverings etc complete all as specified and directed by Engineer-in-Charge
M & L for 75 mm thick Cement concrete type D-2, (1:4:8) (using 40mm graded stone aggregate) etc complete all as specified and directed by Engineer-in-Charge
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of floor etc complete all as specified and directed by Engineer-in-Charge
M&L for glazed ceramic coloured tiles of size 350 x 250 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of floor etc complete all as specified and directed by Engineer-in-Charge
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm as in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in whte or coloured cement to match the the shade kota stone including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in white or white or coloured cement to match the shade of kota stone including rubbing and polishing white or etc complete all as specified and directed by Engineer-in-Charge
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed on vertical surfaces such as skirting over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of kota stone including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
M&L machine cut cudappa stone slab 20-25 mm thick over cement screed base, laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), set and jointed with grey cement slurry and pointed in grey cement mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
M&L for granite(of any type) work(table rubbed and polished) as in cooking plateform and like, set in cement and sand mortar (1:4) incl pointing in white cement (1:2) using marble dust mixed with admixture of pigment to matach the shade of granite thickness of granite, 16 to 18mm etc complete all as specified and directed by Engineer-in-Charge
M&L for machined pressed precast concrete interlocking paver block glossy with grey cement and pagment, any shpae and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over a stone dust cushion of 30mm thick etc complete all as specified and directed by Engineer-in-Charge
M&L for Shahabad stone 20mm to 25mm thick flooring over and including 15mm thick screed bed etc complete all as specified and directed by Engineer-in-Charge
Demolition of plain cement concrete solid block masonary,stone /brick/ RRwalling built in cement mortar etc complete all as specified and directed by Engineer-in-Charge
M&L for brick work with fly ash bricks straight or curved on plan exc 6m mean radius, built in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 15 mm thick on stone masonry surfaces in cement and sand mortar (1:6) on wall finished even and smooth without using extra cement with sagol finish etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 10 mm thick on concrete surfaces in cement and sand mortar (1:4) on ceiling finished even and smooth without using extra cement with sagol finish etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 10 mm thick on stone masonry surfaces, concrete surface in cement and sand mortar (1:4) on wall or roof finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of cement paint on newly / old plastered surfaces including preparation ofwall etc complete all as specified and directed by Engineer-in-Charge
M&L for applying 3 coats of white wash on newly / old plastered surfaces including preparation of wall, etc complete all as specified and directed by Engineer-in-Charge
M&L for applying 3 coats of white wash on newly / old plastered surfaces including preparation of ceiling etc complete all as specified and directed by Engineer-in-Charge
M&L for applying 2 coats of Oil bound distemper on newly plastered surfaces of walls over and including 2mm thick wall care putty incl prepration of surface etc complete all as specified and directed by Engineer-in-Charge
M&L for complete removal of existing treatment and applying two coats of OBD over and including 2 mm thick wall care putty on old plastered surfaces of walls including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for providing waterproofing treatment on roof / chajja as per latest zonal specification, as per manufacturer's instructions and as specified after taking down / out as existing as site etc complete all as specified and directed by Engineer-in-Charge:- (a) M&L for cleaning the newly plastered surface with wire brushes and applying two coats of bituminous primer @ 0.25ltrs/sqm and allow to dry. (b) M&L for applying and laying torch APP polymer midified bituminous membrane 3mm thick with non woven polyster matt as reinforced weighing not less 3 kg / Sqm with white gravel/mineral finished by thermofusion process
M&L for screed bed or bedding layer of mortar 10mm thick in cement and sand mortar (1:3) by using 100% course sand on roof/chajja mixed with & including M&L for WPC @ 3% by weight of cement and finishing the surfaces even and smooth without using extra cement to receive water proofing treatment etc complete all as specified and directed by Engineer-in-Charge
Material and labour for false ceiling with 4 mm thick plain non asbestos building 'E' board with decorative finish water proofed on one side fixed on and including powder coated GI fabricated grid of 60 cm X 60 cm made out of main runner of 'T' section of size 32 mm X 24 mm X 0.30 mm, cross runner made out of 'T' of section of size 24 mm X 24 mm X 0.30 mm and alround angular section of size 22 mm X 22 mm X 0.70 mm with GI clip and level adjuster duly suspended by 4 mm dia GI wire fixed to roof at 1200 mm centre to centre as per manufacturere's instructions and etc complete all as specified and directed by Engineer-in-Charge
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge
Supply and fix 0.50 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc complete all as specified and directed by Engineer-in-Charge
Material and labour for special treatment to sunken slab floor incl WC trap etc including cleaning and preparing the surface area for carrying out membrane water proofing treatment, then injection grouting the weak areas on the concrete surface with cementitious grout and applying 10mm thick cement plaster in CM 1:4. Then providing and laying Mineral Top APP (Atactic Polypropylene Polymer) modified prefabricated 5 layer 4mm thick water proofing membrane, black finished rainforce with non woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Litre per Sqm by the same membrane manufacturer of density at 25ºC, 0.87-0.89 Kg per litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torach and sealing all joints etc and preparing the surface complete. and providing PCC 1:5:10 type E2 using 40mm graded mechanically crushed stone aggregates in sunken slab and 75mm thick PCC 1:4:8 type D2 using 40mm graded mechanically crushed stone aggregates as base, 40mm bore GI pipe, light grade of length not less that 50 cm as spout, non-skid glazed tiles as per existing pattern/size/tint with and incl WC viterous china squatting pan 580x440mm with integral footrests/pedastal pan incl seat cover, white, area of WC exc 1.00 Sqm but nexc 5.00 sqm etc after dismantling the existing sunken floor etc complete etc complete all as specified and directed by Engineer-in-ChargeNote : Work has to be carried out strictly by the authonticated applicator of the manufacturer and as per manufacturers specification as approved by GE.
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 Sqm each with shutters (without taking off shutters from the frame) etc complete all as specified and directed by Engineer-in-Charge
Taking down steel windows / ventilators, of any description and size each etc complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each etc complete all as specified and directed by Engineer-in-Charge
S&F in repair Steel ventilator with top hung shutter including hinges, steel peg stay, etc complete all as specified and directed by Engineer-in-Charge
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge Note: Wire cloth, glass, guard bars and painting shall be measured and paid separately.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones etc complete all as specified and directed by Engineer-in-Charge
M&L for glazing with 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane etc complete all as specified and directed by Engineer-in-Charge
S&F stainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples etc complete all as specified and directed by Engineer-in-Charge
S&F factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails frame shall be covered with heat moulded plain coloured PVC `C' channel having a PVC sheet strip of 20 mm width stuck and plain colour PVC sheets for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame etc complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter with lock rail and panel of 9 mm B.W.P. commercial plywood. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) etc complete all as specified and directed by Engineer-in-Charge
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel etc complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long aluminium anodised handle, cast type etc complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long mild steel barrel tower bolt, stove enamelled black, with bright bolt etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long mild steel pressed handles, oval type, stove enamelled black etc complete all as specified and directed by Engineer-in-Charge
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge
S&F framed work such as in grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 etc complete all as specified and directed by Engineer-in-Charge
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe etc complete all as specified and directed by Engineer-in-Charge
All as per item No 53 (here-in-before) but 20mm dia pipe.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling etc complete all as specified and directed by Engineer-in-Charge
All as per item No 55 (here-in-before) but 20mm dia pipe.
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm dia PVC (SWR) vent cowl etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm bore PVC (SWR) branch piece double (single Y) equal or unequal etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm dia PVC (SWR) bend any radius etc complete all as specified and directed by Engineer-in-Charge
Supply and fix repairs PVC valveless, syphonic action type, flushing cistern,low level, all accesories all as directed. Make :- Sleek essence series of Hindware or Cat part No E8303 of Parryware or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs wash hand basin vitreous China, flat back of size 550 X 400 mm including a pair of brackets, PTMT waste coupling, 32 mm dia PVC flexible waste pipe and connecting to stop valve and nahani trap etc complete all as directed. Make : Cat Part No 10004 of Hindware or Cat Part No C0475 of Parryware or equivalent in makes imentioned in list of makes in Appendix `C'
Supply and fix in repairs looking mirror of size 600 mm X450 mm etc complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No C 8606 of Parryware or equivalent in makes mentioned list of makes in Appendix `C'
Supply and fix in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistren etc complete all as specified and directed by Engineer-in-Charge. Make :- Cat Part No C0117 Of Parryware or Cat Part No 20042 of Hindware or equivalent in makes mentioned in list of makes in Appendix `C'
S&F in repairs vitreous china wash down water closet (Pedestal pattern) white including fixing bolts with and including plastic water closet seat cover closed pattern with flat bottom and cover and MSCP almn hinges device etc complete all as specified and directed by Engineer-in-Charge connecting to 'P' or 'S' trap etc complete all as specified and directed by Engineer-in-Charge. Make:-Petite series Cat part No C0287(S)/88(P) Incl seat cover Cat part No E8309 of Parryware or equivalent make as per list of makes mentioned in appendix `C
S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including conncetion to flushing pipe and waste pipe providing and fixing plugs bedding urinal against wall etc complete all as specified and directed by Engineer-in-Charge
S&F in repair bib tap 15 mm dia, fancy type chromium plated, cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge
Supply and fix 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as directed.Make:- Cat part No MOR 1010(Orintal series) of MARC or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in repair stop valve, 15 mm dia, cast copper alloy,screwed down high pressure screwed down high pressure with cruitch or butterfly handle screwed both ends for iron pipe or for unions all as directed. Make:- Cat part No MOR 1320 (Orintal series) of MARC or equivalent in in makes mentioned in list of makes in Appendix `C'
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm etc complete all as specified and directed by Engineer-in-Charge
S&F in repair health faucet (hand shower) with 8 mm dia 1 m long flexible tube wall mounted / hooked etc complete all as specified and directed by Engineer-in-Charge Cat Part No 573 of Jaquare or its equivalent make as per list of make mentioned in appendix `C etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs, shower rose with shower arm etc complete all as specified and directed by Engineer-in-Charge Make:- Cat part No MARC MSR1050 (Shower) and MOR 1260(Shower arm) or equivalent in makes mentioned in list of makes in Appendix `C'
S&F in repair chromium plated grating 100mm dia etc complete all as specified and directed by Engineer-in-Charge
S&F in repairs, aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges etc complete all as specified and directed by Engineer-in-Charge
S&F in repair stainless steel kitchen sink 0.63 mm thick or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm etc complete all as specified and directed by Engineer-in-Charge
S&F in repair stainless steel plate rack 0.63mm thick sheet for kitchen ( Size 31"x 36' x 10') etc complete all as specified and directed by Engineer-in-Charge
Dismantling of water tanks of capacity 500 ltr and n.exc 1000 ltrs and removing from site etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs rotational moulded polyethylene water storage tanks double layer ISI marked (cylindrical vertical with closed top) of 1000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to irin pipe and connecting etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs rotational moulded polyethylene water storage tanks double layer ISI marked (cylindrical vertical with closed top) of 500 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to irin pipe and connecting etc complete all as specified and directed by Engineer-in-Charge
S & F of ball brass valve, 20mm bore dia of pipe, high pressure with polythene float and flynet complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed by Engineer-in-Charge
Supplied and fixed 20mm Bore gun metal and glob or gate valve with iron wheel head, screwed both ends for iron pipe etc complete all as specified and directed by Engineer-in-Charge
S&F in repairs 32 mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge
Demolition and breaking up 150 mm bore drain pipe i.e. salt glazed ware, AC or reinforced concrete pipe , set in cement mortar etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation etc or for walls, shafts, manholes not exc 10 Sqm on plan and getting out, in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, wtering, and well ramming etc complete all as specified and directed by Enginee-in-Charge
Removing surplus excavated soil to a distance n.exc. 50 metre and depositing where directed at a level n.exc.1.5 metre high from the starting point etc complete all as specified and directed by Enginee-in-Charge
Material & labour for 150 mm bore Reinforced cement concrete pipe, type NP2 , haunching against the sides of pipe in PCC (1:4:8) type D-2 using 40mm graded mechanically crushed stone aggregates and making necessary connection after cutting into existing sewer line/manhole to make it functional etc complete all as specified and directed by Engineer-in-Charge for the following :- .
Dismantling posts or struts (wood steel or RCC) any section, including taking out embeded portion in concrete, brick work, masonry etc and making good distrubed etc complete all as specified and directed by Engineer-in-Charge
Excavation in post holes each n. exc. 50 cum getting out in soft/loose soil and removing surplus material n. exc 50 mtr and making good distrub surfaces etc complete all as specified and directed by Engineer-in-Charge
Material and labour for PCC (1:3:6) type C-2 using graded stone aggregate as in Fdn Posts and struts etc complete all as specified and directed by Engineer-in-Charge
S&F in repair Galvanised, 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails including securing or tying with and provision of galvanised MS wire staples or steel pins etc complete all as specified and directed by Engineer-in-Charge
S&F ISA 75 x 75 x 5mm as in posts and struts in fencing including cutting tops to shape as directed, drilling holes notching for wire etc conforming to Fe 410 or Fe 310 etc complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces including prepration of surfaces etc complete all as specified and directed by Engineer-in-Charge
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc complete all as specified and directed by Enginee-in-Charge
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of CI/pressed steel terminal switch box and white bakelite plastic laminated top sheet cover and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following etc complete all as specified and directed by Enginee-in-Charge. (Make of Cable : Finolex/RR Cable/Havells & Make for Casing & capping : AKG/PRESTOPLAST/PRECISION): - Note : 1. Porper colour coding shall be adopted utilize for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by one No piano type switch 5 Amps single pole one way
One fan point controlled by one No piano type switch 5 Amps single pole one way
One bell point controlled by one No push type switch 5 Amps single pole one way
One 3 pin 5 Amps socket outlet on same board controlled by one No piano type switch 5 Amps single pole one way
One 3 pin 5 Amps socket outlet on independent board controlled by one No piano type switch 5 Amps single pole one way
All as per Item No 94 (here-in-before) but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket outlet on independent board
S&F switch piano flush type single pole, one way 5/6 Amps etc complete all as specified and directed by Enginee-in-Charge
S&F Switch socket combination 2 in 1, 5 Amp flush type 230V AC etc complete all as specified and directed by Enginee-in-Charge
S&F Switch socket combination 5 in 1, 5/16 Amps flush type 230V AC etc complete all as specified and directed by Enginee-in-Charge
S&F bell push flush type single pole one way 5/6 Amp etc complete all as specified and directed by Enginee-in-Charge
S&F bell ding dong elelctric 230V AC single pole etc complete all as specified and directed by Enginee-in-Charge
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet as required etc complete all as specified and directed by Enginee-in-Charge
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Enginee-in-Charge
M&L ceiling rose 3 terminal / PVC/ polycarbonate, isolated body etc complete all as specified and directed by Enginee-in-Charge
S&F in replacement double door Sheet metal enclosures factory made DBs 8 way, (SPN DB's) 240 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Enginee-in-Charge Make: Legrand Cat No 507611 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply & fixing MCB , SP, AC, 240 volts of 06 to 40 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs complete etc complete all as specified and directed by Enginee-in-Charge. Make: Legrand, Cat No. : 4085-87 to 90,92,93,94,95 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply & fixing MCB, SPN, AC, 240 volts of 40 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Enginee-in-Charge. Make: Legrand 4086-17 to 20 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply & fixing MCB, TPN, AC, 415 volts of 63 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Enginee-in-Charge. Make: Legrand or equivalent in makes mentioned in list of makes in Appendix `C'
Supply & fixing MCB, SPN, AC, 240 volts of 63 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Enginee-in-Charge.
S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Enginee-in-Charge Make ; Havells E-LITE LED PRIDE PLUS NEO Cat No LHEXACP71N1W020) or its equivalent makes mentioned list of makes in Appendix `C'
S & F Lumeno LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder and wall light
S&F in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ etc complete all as specified and directed by Enginee-in-Charge. Make -Havell's Cat Part: (ENDURAPEARLSL25W MP) ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent makes mentioned in list of makes in Appendix `C'
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through in and incl PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Enginee-in-Charge (Make of Cable : Finolex/RR Cable/Havells & Make for PVC Casing & Caping : AKG/PRESTOPLAST/PRECISION): - Note : 1. Porper colour coding shall be adopted utilize for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) Note: Two run of 6 sq.mm cable i.e for one run for phase, one run for neutal with one run of 6 sq.mm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25mtr depth and top edge of the earth plate not less than 1.5mtr below normal ground level connected to galvanised earth lead wire 4.0Sqmm dia by means of nuts,bolts & washer etc. Earth wire connected upto main earth point/DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 ( using 20 mm graded stone agregate) and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of ms bar @ 15 mm CIC with both way lifting arrangement complete including all necessary excavation & earth work etc complete all as specified and directed by Enginee-in-Charge
M&L for sub main wiring with two runs of PVC insulated and unsheathed FRLS cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through existing conduit and 4 Sqmm single core multisranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed (Note : Two runs of conductor with one run of earth wire and PVC casing & capping will be measured & paid as one unit) etc complete all as specified and directed by Enginee-in-Charge
Supply and fix in replacement industrial type switch socket for Geyser with 20 Amps MCB Make : Legrand Cat No. 6078 41 20 A SP or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix heavy duty exhaust fan, 300 mm sweep, 900 RPM, 230 V, 50 Hz with fixing of fan duly grouted in bolts and connecting with 3 core flexible copper cable of size 1.5 Sqmm all as directed including making holes in wall/window etc complete all as specified and directed by Enginee-in-Charge
Supply and fix Water heater storage type, electric, capacity 25 litre, BEE 5 star rated including water supply connection etc complete all as specified and directed by Enginee-in-Charge. Make.Havells Cat No GHWAPXTWB025/ or equivalent in makes mentioned in list of makes in Appendix `C'
S&F in replacement double door Sheet metal enclosures factory made DBs 4 way, (TPN DB's) 415 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Enginee-in-Charge
S&F in replacement double door Sheet metal enclosures factory made DBs 4 way, (SPN DB's) 240 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Enginee-in-Charge
Supply and laying or fixing or passing in trenches/ on pole / through pipes, 1100 volts grade XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of cross sectional area 16 sq mm 4 core including connection with cable glands & lugs etc and testing on completion etc complete all as specified and directed by Enginee-in-Charge
S&F Decorative, wall mounting fixture, in durable plastic body & designer mesh in gold finish , suitable for 14 W retrofit CFL/LED (B-22 base) with and including lamp holders, connector block and retrofit type LED lamp 1 x 10 W (including suitable LED Lamp 10 W), complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable etc complete all as specified and directed by Enginee-in-Charge. Make - Havell's Cat Part No: (GLAZE Upto 14 W Retrifit CFL (B22) LHFOECE1TZ1B014 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply &lay HDPE pipe 65 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Enginee-in-Charge
An amount of Rs 76,105.00 shall be deducted from BOQ on account of schedule of credit
M/s AG PATHAN
M/s.Abhay Kulkarni and Associates
Ms. M.D. Auty
Priyadeep Construction
M/S-B.R.SONAWANE
OM SAI ASSOCIATES
M/s. A P INFRA
M/s. Sagar Traders
sunway associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .