Executive Engineer
Electrical Division PWD BnR Br. Rohtak
Construction of District Library at Safidon in District Jind (Providing E.I. and Security Lights only) (Under D - Plan).
2022_HRY_215498_1
PWD/Electrical/55673
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Jind
Please refer to tender documents as per DNIT Conditions.
3 documents required · 3 mandatory
₹500
₹9,120
Yes
25 Apr 2022
4 Apr 2022
18 Apr 2022
4 Apr 2022
14 Apr 2022
4 Apr 2022
120 days
Amount
HSR Items
Ceiling Fan / Exhaust Fan
20.71 Supply, Erection, Testing of Ceiling Fan ISI marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-Charge
20.72 Supply, Erection, Testing of Exhaust Fan IS marked (as per IS code 374)having a capacity of 45 cubic meter per minute complete with suitable GI sheet ducting in structure confirming to latest IS specifications complete in all respects complete to satisfaction of Engineer-in-Charge Make: Orient/Havells / Khaitan / Usha
23.3.6 Wiring main and sub mains in Two single core for phase and neutral wire and one single core for each wire PVC insulated copper conductor cable 1100 volts grade in PVC conduit etc as required
23.3.6.1 1 run of size 1.50 Sqmm (1/1.40 mm)
23.3.6.3 1 run of size 4 Sqmm (1/2.24 mm)
23.3.6.5 1 run of size 10 Sqmm (1/3.50 mm)
23.4 Copper Wiring with Modular Switches in PVC Conduit
23.4.1 Wiring for Light / Fan / Call Bell Point with Modular Type Switch / Socket and GI Box, Modular Type Face Plate etc. in 1.5 Sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC Conduit Pipe
23.4.1.2 Group B
23.4.4 Wiring in PVC Conduit System for 3 - Pin 5 Amp. Plug Point by using 2 Nos. 1.5 Sqmm FRLS Copper wire and 1 No. 1.5 Sqmm FRLS Copper wire including providing 1 No. 5/6 Amp. 3/5 Pin Modular Type Socket and 1 No. 5/6 Amp. Modular Type Switch required GI Box Modular Face Plate etc. complete as required
23.4.4.2 Group B
23.4.5 Wiring in PVC Conduit System for 3 - Pin 15 Amp. Plug Point by using 2 Nos. 4 Sqmm FRLS Copper wire and 1 No. 4 Sqmm FRLS Copper wire for earthing including providing 1 No. 15/16 Amp. 3/6 Pin Modular Typ Socket and 1 No. 15/16 Amp. Modular Type Switch required GI Box Modular Face Plate etc. complete as required
23.4.5.2 Group B
23.7.6 Supply and Erection of PVC Conduit ISI Marked (Medium) recessed in wall / ceiling etc. including the cost of PVC bends inspection boxes, iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-Charge of work
23.7.6.2 PVC Pipe of 25 mm dia
23.8 Fittings and Accessories.
23.8.1 Providing and fixing Paino type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connection, complete in all respect
23.8.1.12 Bakelite angle / straight button holder large size.
23.8.4 Supply and erection of 10.5 cm dia MS Fan box including 8 mm dia 30 cm long MS road made into suitable suspension hook and erected in RCC slab for the erection of fan complete with all labour and material required to complete the job
23.8.11 Providing and Fixing Modular Type Accessories of approved make in existing box including fixing and making necessary connections complete in all respect
23.8.11.1 5 Amp. 1 Way Switch
23.8.11.4 5 Amp. Socket
23.8.11.7 Step Type Fan Regulator 2 Modules 300 watt
23.8.11.10 Blanking Plate
23.22 MCCB, Distribution Boards, MCB's, RCCB's, Change Over etc.
23.22.1 Supply and erection of modular case circuit breaker single pole / 4 pole on existing wall / pedestal / panel including bounding to earth and making necessary connections required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work.
23.22.1.9 4 Pole MCCB 6 Amp. to 100 Amp., 25 KA
23.22.2 MCCB enclosure made of sheet steel suitable for mounting MCCB of following ratings
23.22.2.1 MCCB upto 125 A FP
23.22.3 Supply and Erection of Sheet Steel enclosures 1 Pole / 2 Pole / 4 Pole on wall / on existing pedestal complete as required
23.22.3.2 SPN or DP enclosures suitable for DP MCB
23.22.4 Supply and erection of double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.
23.22.4.7 TPN DB Horizontal type Double Door 8 way (8 incoming and 3 phase * 8 outgoing)
23.22.5 Supply and erection of miniature circuit breaker 240/ 415 V in the existing distribution board including making necessary connections
23.22.5.1 6 Amp. to 32 Amp. Single Pole
23.22.5.3 6 Amp. to 32 Amp. Double Pole
23.22.5.8 40 Amp. to 63 Amp. MCB's Four Pole
23.23.2 Supply of GI Pipe (B-Class) for suspension rod of ceiling fan including threading if required
23.23.2.1 Size 15 mm dia
23.24 MS Stand Bus Bar Chamber and Panels
23.24.3 Supply and Erection of Metal Clad bus bar chamber made from 1.6 mm thick MS Sheet and fixing with rag bolts on wall or on existing pedestal / angle iron frame including bonding detachable top and bottom including painting and necessary connection etc. (Aluminium Bars)
23.24.3.2 100 Amp. 4 bars of 55 cm each (Cross Section 25 mm x 6 mm) Chamber overall size 60 cm x 45 cm x 18 cm
24.1 Earthing and Lightening Arrestor
24.1.1 Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. (but without charcoal or coke and salt) as required
24.1.2 Extra for using salt and charcoal/coke for earth electrode as required.
24.1.14 Supply and Erection of 20 mm x 3 mm thick GI Tape fixed with suitable GI Staples of same size
24.5.2 S/E of mark double walled corrugated (DWC) HDPE pipe10 Kg./Cm2 laid 0.75 mtr. below ground level including digging and refilling of earth including cost of suitable size socket / coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of the work
24.5.2.3 DWC/HDPE pipe 63/50 mm outer dia / inner dia
MR Items
N.S - 1 S/E of underground cable loose in existing pipe or trenches complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.
i) 10 Sqmm 4 Core Cable (Armd.)
ii) 25 Sqmm 4 Core Cable (Armd.)
N.S - 2 Supply and Erection of LED flood light fitting of Phillips make BVP192 LED 110 W CW HO NB FG GR PSU or its equivalent model of Havells /Wipro /Bajaj with pressure die cast aluminium housing, reflector and enclosed with toughened glass with all accessories as supplied by the manufacturer complete in all repect upto the entire satisfaction of Engineer-in-Charge of the work.
N.S - 3 Supply and erection of LED Tube Light 40 Watt Model of Phillips, Havells, Bajaj, Wipro etc. complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.
N.S - 4 Supply and erection of LED Panel 2' x 2' 32 Watt complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make: Havells / Bajaj / Phillips / Wipro
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .