Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.1 CrAccepted-AOC 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | ₹9.1 Cr Quoted ₹9.6 Cr | L-1 | Accepted-AOC Lowest |
| 2 | L-2₹9.9 Cr+₹30.0 L (3.13%)Rejected-Finance | ₹9.9 Cr+₹30.0 L (3.13%) | L-2 | Rejected-Finance Other than Lowest |
| 3 | L-3₹10.0 Cr+₹39.3 L (4.10%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹10.0 Cr+₹39.3 L (4.10%) | L-3 | Rejected-Finance Other than Lowest |
| 4 | L-4₹10.1 Cr+₹48.5 L (5.06%)Rejected-Finance SCF 134 1ST FLOOR ROSE GARDEN COMPLEX GT ROAD BATHINDA 151001 PUNJAB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹10.1 Cr+₹48.5 L (5.06%) | L-4 | Rejected-Finance Other than Lowest |
| 5 | L-5₹10.4 Cr+₹85.6 L (8.94%)Rejected-Finance | ₹10.4 Cr+₹85.6 L (8.94%) | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹10.9 Cr
EMD Value
₹8.7 L
Closing Date
27 Jan 2022, 6:00 pmClosed
CE Bathinda
HQ CE Bathinda BATHINDA MIL STN
AUGUMENTATION AND UPGRADATION OF LT POWER SUPPLY TO MD AND OTM ACCN AT BATHINDA MIL STN
2021_MES_493991_1
CE BTZ/BTD/TOKEN-20 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Bathinda Mil Stn
as per NIT
10 documents required · 10 mandatory
₹3,000
GE (U) Bathinda
₹8.7 L
Yes
7 Feb 2022
13 Dec 2021
29 Jan 2022
13 Dec 2021
27 Jan 2022
15 Jan 2022
Amount
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 800 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1200 Amp - 01 Set
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 4 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 150 Amp - 01 Set
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1600 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 2400 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 300 Amp - 01 Set
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 09 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 240 Amp - 01 Set
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 08 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1600 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 2400 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 300 Amp - 01 Set
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 11 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1000 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1500 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1000 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1500 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 300 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 240 Amp - 01 Set
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 07 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1250 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1875 Amp - 01 Set
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 1000 Amp - 01 Set
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1600 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 2400 Amp - 01 Set
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 1000 Amp - 01 Set
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 300 Amp - 01 Set
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 10 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 800 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1200 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1000 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1500 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 1000 Amp - 01 Set
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1250 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1875 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 300 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 300 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1250 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1875 Amp - 01 Set
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 08 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1000 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1500 Amp - 01 Set
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1000 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1500 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 07 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 800 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1200 Amp - 01 Set
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 1000 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 240 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 06 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 300 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 07 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 125 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 125 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 200 Amp - 01 Set
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 06 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 125 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 125 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 200 Amp - 01 Set
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 1000 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 800 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1200 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 125 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 125 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 800 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1200 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 125 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 125 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 200 Amp - 01 Set
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 1000 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 06 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 800 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1200 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 300 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1000 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1500 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 300 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 06 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 800 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1200 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 300 Amp - 01 Set
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 08 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1000 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1500 Amp - 01 Set
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 630 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 1000 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1000 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1500 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 06 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 150 Amp - 01 Set
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 04 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 800 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1200 Amp - 01 Set
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 200 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 32 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 05 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 800 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1200 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 125 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 125 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 200 Amp - 01 Set
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 06 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 160 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 240 Amp - 01 Set
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 1000 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1500 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
Air circuit breaker 4 Pole 630 amps, 415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 No (incoming)
Aluminium Busbar 1000 Amp - 01 Set
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 400 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 06 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 400 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 600 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 315 Amps, 415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No (incoming)
Aluminium Busbar 500 Amp - 01 Set
MCCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 02 Nos (outgoing)
MCCB 4 Pole, 40 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 03 Nos (outgoing)
LED type Indicator lamp (R,Y,B) - 01 set
Supply, installation, commissioning and testing of factory made (CPRI approved) LT feeder Pillar Box of size 90x60x40cm, out door type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, pillar box shall be mounted on angle iron frame and 04 No legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, internal wiring of pillar box with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 16 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type. - 01 No
Aluminium Busbar size 40x5mm suitable length with RYBN sleeves - 01 Sets
Notes for srl item No 01 to 93 :- (i) All type of spares such as glands, lugs, nuts, bolts, thimbles etc, necessary excavation and earthwork and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel and feeder pillar box shall be approved by GE before fabrication. (iii) Pre dispatch inspection (Factory inspection ) of LT panel and feeder pillar box shall be carried out by the representative of the Accepting Officer. Contractor shall intimate the planned date of inspection well in advance. All incidental expenditure for getting the inspection/testing in the factory premises shall be borne by the contractor including transportation and administration arrangement for the rep of accepting officer without any extra cost to the department.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 400 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 300 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 240 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 185 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 150 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 120 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 95 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 70 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 50 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 35 Sqmm 3.5 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 25 Sqmm 4 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 16 Sqmm 4 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, complete all as specified and as directed.
Note for srl item No 95 to 106 :- (i) Excavation and earth work, sand cushioning, protection cover & GI pipe shall be measured and paid separately under appropriate item of BOQ. (ii) Pre dispatch inspection (Factory inspection ) of LT cable shall be carried out by the representative of the Accepting Officer. Contractor shall intimate the planned date of inspection well in advance. All incidental expenditure for getting the inspection/testing in the factory premises shall be borne by the contractor including transportation and administration arrangement for the rep of accepting officer without any extra cost to the department.
Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip of size 25 x 4 mm flat by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe ISI marked. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe ISI marked for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as directed. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and earthing strip upto electric equipment from top of earth plate i.e. minimum 7.5 metre shall be included in the unit rate of this item. (iii) Test point if required as per site requirement, same shall be measured & paid separately. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of LT cable in trenches or laying of pipes (where provided) for protection of cable or fixing PCC poles and stays or for taking out old cable and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing of surplus excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Material and labour for sand cushioning, with dry and clean fine river sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. (Note:- Punned thickness shall be considered for payment purpose)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed.
Supply and fixing GI tubing light grade of size 40 mm bore, ISI marked, fixed along poles/walls or laid in trenches, under floor for cable protection including fittings (elbow, tee, socket etc) complete all as specified and as directed. (Note:- Excavation and earthwork and MS clamp as required shall be measured and paid separately under respective item of Sch.)
Supply and fixing GI tubing light grade of size 50 mm bore, ISI marked, fixed along poles/walls or laid in trenches, under floor for cable protection including fittings (elbow, tee, socket etc) complete all as specified and as directed. (Note:- Excavation and earthwork and MS clamp as required shall be measured and paid separately under respective item of Sch.)
Supply and fixing GI tubing light grade of size 80 mm bore, ISI marked, fixed along poles/walls or laid in trenches, under floor for cable protection including fittings (elbow, tee, socket etc) complete all as specified and as directed. (Note:- Excavation and earthwork and MS clamp as required shall be measured and paid separately under respective item of Sch.)
Supply and fixing GI tubing light grade of size 100 mm bore, ISI marked, fixed along poles/walls or laid in trenches, under floor for cable protection including fittings (elbow, tee, socket etc) complete all as specified and as directed. (Note:- Excavation and earthwork and MS clamp as required shall be measured and paid separately under respective item of Sch.)
Supply and fixing GI tubing light grade of size 150 mm bore, ISI marked, fixed along poles/walls or laid in trenches, under floor for cable protection including fittings (elbow, tee, socket etc) complete all as specified and as directed. (Note:- Excavation and earthwork and MS clamp as required shall be measured and paid separately under respective item of Sch.)
Supply and fixing MS clamp any size and shape to fixing the pipe along pole as directed made out of FI 25x4mm including nuts, bolts and washer complete all as specified and as directed.
Boring hole/Excavation by trenchless technology for boring of holes under road, pavement, hardstanding using trenchless boring machine or by means of manual manpower suitable for inserting GI pipe including removal of surplus soil and making good disturbed surface complete all as specified and as directed. NOTE:- Pipe for inserting as required shall be measured and paid for separately.
Material and labour for cable route indicator post of size 300x200x100mm made of precast cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate, rounded tops as directed and grounting in ground with PCC (1:3:6) type C-1, using 20 mm graded stone aggregate bock of size 250x150x150mm, including 5 mm thick plastering all round of exposed surace of post above ground with CM (1:4) and finished even and smooth without using extra cement, applying two coats of cement base paint on plastered surface including writing letters (like LT UG cable, __ feeder etc.) with synthetic enamel paint in brown colour in suitable size including earth work and form work complete all as specified and as directed.
Dismantling/taking down ACSR conductor from LT poles (over head lines) complete all as specified and as directed.
Dismantling/taking down cross arms of MS channel or angle section etc from LT poles complete all as specified and as directed.
Dismantling/taking down insulator any type and size from LT poles complete all as specified and as directed.
Taking down carefully old existing Main LT Panel from the position, after disconnecting the incomming and out going cable connections from the panel board and removing the panel from existing location and same shall deposit in the store yard of AGE E/M complete all as specified and as directed. Note :- (i) Cost for loading/unloading, transporting from site to MES store yard shall deemed to be included in the quoted unit rate. (ii) The above main panel should be disconnected after the installation of proposed new panel.
M/s Kataria Construction Company
FRIZO INDIA PVT LTD
ENGINEER CONSTRUCTION PVT. LTD.
BANSI BUILDER AND CONTRACTORS PVT LTD
SAGGI ELECTRIC COMPANY
A.S. CONSTRUCTION CO.
VIJAY JINDAL BUILDERS PVT LTD
A.V BUILDERS
Phoenix Infra
MICKY CONSTRUCTION PVT LTD
JAY BEE Industries
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .