Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹67.8 LAccepted-AOC DEVI KRUPA 77 NEW KHB COLONY HABBUWADA KARWAR KARNATAKA 581 306 | KARWAR | UTTARA KANNADA | KARNATAKA | 581306 | 1 | Accepted-AOC Being L1 | |
| 2 | 2₹69.5 L+₹1.7 L (2.58%)Rejected-Finance | 2 | Rejected-Finance Since Not L1 | |
| 3 | 3₹69.6 L+₹1.8 L (2.69%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | 3 | Rejected-Finance Since Not L1 | |
| 4 | 4₹72.4 L+₹4.7 L (6.88%)Rejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | 4 | Rejected-Finance Since Not L1 | |
| 5 | 5₹77.1 L+₹9.3 L (13.7%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | 5 | Rejected-Finance Since Not L1 |
Tender Value
₹75 L
EMD Value
₹87,500
Closing Date
17 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer Rnd secunderabad
Chief Engineer Rnd Opp jubilee bus stand Picket secunderabad
ADDITION ALTERATION CONVERSION OF REPROGRAPHY SECTION TO STRUCTURAL MECHANICAL GROUP AND SQAG IV and V LAB AT GTRE BANGALORE
2023_MES_601977_1
82643
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Bangalore
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE I RnD East Banglore
₹87,500
Yes
10 Aug 2023
9 Jun 2023
24 Jul 2023
9 Jun 2023
17 Jul 2023
3 Jul 2023
Amount
Demolition of RCC work of any description and in any position not otherwise specifically provided for and including the debris to a distance exc 5 KM but not exc 10 KM outside MD land complete all as specified and directed.
Demolition of brick work or stone / boulder masonry built in cement mortar etc including removing the debris outside MD land complete all as specified and directed.
M&L for pre-cast cement concrete block masonry type C1, 1:3:6 (using 20 mm graded aggregate) with solid blocks not exc. 10 cm in width and setting in cement and sand mortar 1:4 complete all as specified and directed.
M&L for 10 mm thick internal plaster in CM 1:4 on faces of walls, finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for 5 mm thick plaster in CM 1:3, as in ceiling, finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered surfaces of walls and applying two coats of distemper oil emulsion paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparing new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatment and applying two or more coats of 100% Premium Acrylic emulsion paint having VOC less than 50gm / litre and UV resistance as per IS 15489:2004, Algae and fungal resistance, dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives @1.43 litre / 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 Sqm over new surfaces of walls complete all as specified and directed.
M&L for 2 mm thick wall care putty on wall complete all as specified and directed.
Use and waste of formwork to sides of soffit of floor or roof beams, beam landings, lintel etc for flat rough finished surfaces of concrete complete all as specified and directed.
M&L for reinforced cement concrete type B-1, 1:2:4 using 20 mm graded aggregates as in beams, cantilevers bressummers, lintels over 1.5m span complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per Sl item No. 13 but, 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders.
Taking down chowkhats or frame not exceeding 1.5 Sq.m each with shutter(s) (without taking off shutters from the frame) complete all as specified and directed.
All as per Sl item No.15 but, exc 1.5 sqm but n.exc 4 Sqm.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F, powder coated aluminium frame for doors and windows, ventilators, partition with one or more rebates including joining cleat, rubber beading for fixing, star lock, sliding arrangement for sliding shutters etc complete all as specified and directed.
S&F, powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 02 Nos in each door, aluminium hinges, anodised aluminum snap beading screws etc. thickness of powder coating not less than 50 microns complete all as specified and directed.
S&F, powder coated aluminium window and ventilator shutters, side hung / sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as star lock etc, thickness of powder coating not less than 50 microns complete all as specified and directed.
S&F, aluminium body door closer hydraulically regulated designation No. 2, universal type suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg, complete all as specified and directed.
S&F, floor door stopper (double headed) of aluminium body and toungue, anodized with hard drawn steel spring 150mm complete all as specified and directed.
S&F, 4 mm sheet glass, ordinary quality with Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers and glazing with aluminium beads in square exc 0.5 sq.m in each pane complete all as specified and directed.
S&F, 9 mm thick prelaminated particle boards exterior grade, prelaminated both sides with decorative chocie laminations fixed in aluminium partions / doors with rubber beadings complete all as specified and directed.
S&F, sheet glass ordinary quality for 5.50 mm thick and glazing with oil putty in sqm exc 0.50 sqm in each pane with solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
S&F, anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design / pattern, with approved standard section and fixed to the existing window frame with CP brass / stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge.
S&F, for venetian blinds vertical type 100 mm width with approved fabric and powder coated aluminium fittings such as top rails metal weight nylon button loops etc to match with the top rail metal base complete all as specified and directed.
Preparation of old painted steel surfaces of any description over 10 cm girth or width and applying one coat of synthetic enamel paint all as directed by Engineer-in-Charge.
Providing and fixing of false ceiling system with fine fissured edge tiles having humidity resistance (RH) of 95% NRC 0.34, light reflectance approx 84%, Thermal conductivity K=0.052-0.057 W/MK, colour white, fire performance of class-I as per BS 476 Part 6 & 7 in module size 600 x 600 x 16 mm thick suitable for green building application with recycled content of 38-41% with Armstrong silhoette profile exposed grid system with 15 mm white flanges incorporting a 6 mm central reveal in white / black colour. Silhoutte, main runners & cross Tees to have mitred ends & "birdsmouth" notches to provide mitred cruciform junctions. The Tee sections have a galvanizing of 170 grms per m2 & passed through 500 hrs of salt Test.The main runner spaced at 1200 mm c/c should be securely fixed to the structural soffit using Armstrong suspension system at 1200 mm maximum c/c. The first / last Armstrong suspension system at the end of each main runner should not be greater than 450 mm from adjacent wall complete all as specified and directed. Make: Armstrong / Saint Gobain or equivalent.
Grinding & Polishing of existing Mosaic flooring removing thin layer of stone flooring using good quality of grits in a single disc machine removing tough stains and scratches from the floor after cleaning apply good quality mirror polish complete all as specified and directed.
Taking down exiting copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed by Engineer-in-Charge.
Taking down exiting copper / aluminium sub main wiring complete for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed by Engineer-in-Charge.
Taking down exiting MCCB / MCB DBs complete for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed by Engineer-in-Charge.
M&L for point wiring complete with multistranded copper conductor size 1.5 sqmm PVC insulated, unsheathed, FRLSH cable, 1100 volts grade conforming to IS 694 multistranded, drawn in and including non-metallic rigid PVC conduit 25mm dia medium grade and conduit fittings concealed in walls / floor but except roof / beams etc including GI modular flush boxes and modular white plates and frames for mounting sockets, modular type switches, regulator and also including 1100 Volts, FRLSH grade, 1.5 Sqmm, single core, PVC insulated, unsheathed, multistranded copper conductor cable copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly for One light / fan point controlled by one way switch.
All as per Sl item No. 34, but for one 5 Amps socket point on independent board.
All as per Sl item No. 34 above, but for 3 pin, 16 Amps socket outlet on independent board with 1100 Volts, FRLSH grade, 4 Sq.mm, single core, PVC insulated, unsheathed, multistranded copper conductor cable, conforming to IS-694 and including 1100 Volts, FRLSH grade, 4 Sq.mm, single core, PVC insulated, unsheathed, multistranded copper conductor cable, conforming to IS-694 as earth continuity conductor and connecting to earth dolly.
S&F, switch modular type single pole, 1 way, 6 Amps, 230 volt complete all as specified and directed.
S&F, socket outlet modular type 6A 2/3 Pin combination 2 module complete all as specified and directed.
S&F, ceiling rose surface bakelite three terminal complete all as specified and directed.
S&F, switch modular type 1 way, 16A, 1 module complete all as specified and directed.
S&F, socket outlet modular type 6A / 16A, 6 pin combined 2 module, 230Volts grade complete all as specified and directed.
S&F, modular type fan regulator 120 W two module complete all as specified and directed by Engineer-in-Charge.
Dismantling and refixing the ceiling fan / exhaust fan complete of any type and size, cleaning, servicing, painting greasing to bearings checking of nuts bolts, safety split pin, bushes, capacitor and complete spray painting as directed by Engineer-in-Charge. Note: Expendable stores like cotton waste / cleaning materials, grease, lubricants, machine screws, safety split pin, bots / nuts and transportation to and from site to work place are deemed to be included in rate quoted.
S&F, recess mounted full panel LED luminaire 36 watt fitting 2' x 2' with white powder coated housing & frame in CRCA sheet, high efficiency LED grade diffuser, electronic driver duly wired upto terminal block, CRI >80, colour temperature-5700K, IP-20, 50000 burning hours as per L70 criteria, ambient temperature-0 to 50DegC, driver efficiency >85%, THD<10%, power factor >0.95, surge protection in CM-3KV, multistage isolated constant current-constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard complete all as specified and directed.
S&F, high efficient LED street light fitting 35 watt with aluminium pressure die cast housing parts for long life, high purity PC fresnel diffuser with silicon gaskets for IP-65 protection, in-built electronic driver pre-wired upto terminal block, suitable for external pole dia upto 35 mm, CRI >70, temperature range-0 to 45 DegC, driver efficiency >85%, power factor >0.95, THD<10%, colour temperature-5700K, surge protection in CM-3.5KV, 50000 burning hours as per L70 criteria, multistage isolated constant current-constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard in and including 1.5 Mtr length GI tubing medium grade suitable dia and adequate length bent to shape with necessary CI clamps, bolts etc for fixing and connecting from ceiling rose to filling with 3 core 1.5 Sqmm insulated copper cable complete all as specified and directed.
S&F, LED batten 20 watts, 4 feet with aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & intregrated electronic driver and fixing on wall / celing with LED rod complete all as specified as directed.
Sub main wiring complete with 2 runs of 4 Sqmm PVC insulated and unsheathed cable with multistranded, FRLSH grade copper conductor confirming to IS-694, 1100 volts grade with colour code and drawn through and including 25mm dia PVC non metallic rigid conduits medium grade and conduit accessories concealed in walls / floors but except roofs / columns / beams etc and connecting terminal ends including 1 x 4.0 Sqmm PVC insulated unsheathed copper conductor cable green colour as continuous earth continuity conductor and connecting to earth complete all as specifiedand directed. Note: Two runs of 4.0 Sqmm copper cable, one run of earth wire of 4.0 Sqmm copper cable and 25mm dia PVC conduit shall be measured and paid as one RM.
Sub main wiring complete with 4 runs of 6 Sqmm PVC Insulated and unsheathed cable with multistranded, FRLSH grade copper conductor ISI marked and drawn through and including concealed 25mm dia PVC medium grade non metallic rigid conduit and conduit accessories fixed on walls / floors / ceilings etc and connecting terminal ends including 2 runs of 6 Sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as specified and directed. (for UPS power socket) Note: Four runs of 6.0 Sqmm copper cable, two run of earth wire of 6.0 Sqmm copper cable and 25mm dia PVC conduit shall be measured and paid as one RM.
Sub main wiring complete with 4 runs of 16 Sqmm PVC insulated and unsheathed cable with multistranded, FRLSH grade copper conductor ISI marked and drawn through and including two runs of 25mm dia PVC medium grade non metallic rigid conduit and conduit accessories concealed in walls / floors but except roofs / columns / beams etc and connecting terminal ends including 2 runs of 16 Sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: Four runs of 16 Sqmm copper cable, two runs of 16 Sqmm earth wire and two runs of 25mm dia PVC conduit shall be measured and paid as one RM.
S&F, distribution board power line vertical (VTPN) MCCB DB 8 way with IP-43 protection metal door, 415 volts, suitable copper bus bar each phase 8 way with double door fixed on flush to the wall including making the hole in the wall and fixing the DB including cement work and plastering complete all as specified and directed.
S&F, SPN MCBs distribution board of sheet metal enclosure factory made double door powder coated single pole and neutral with 200 Amps rated bus bar 4 way 240 Volts complete all as specified and directed.
S&F, MCCB with thermal magnetic release 415 volts, 4 pole, 125 Amps capacity and breaking capacity 16 KA all as specified and directed.
S&F, MCB SPN 32 Amps, 240 Volts 'C' curve complete all as specified and directed.
S&F, MCB SP 5-32Amps, 240 Volts 'C' curve single phase all as specified and as directed.
S&F, triple and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB TP 32 Amps, 415 volts, 'C' curve complete all as specified and directed. Note: For Server Room.
S&F, triple and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB TP 63 Amps, 415V complete all as specified and directed. Note: For Server Room.
S&F, single pole and netural enclosure with a two pin and earth plug with socket complete with one MCB double pole 20 Amps, 240 volts, 'C' curve complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts to GI and connected to earthing test point all as shown in elecrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earthwork in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/Sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm light grade 7.5 meter long etc complete tested on completion all as specified and directed. Note: (i) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (ii) GI wire above 7.5m will be measured and paid seperately. (iii) Earth resistance not exceeding 1.0 ohm.
S&F, distribution board power line vertical (VTPN) MCCB DB 4 way with IP-43 protection metal door, 415 volts, suitable copper bus bar each phase 4 way with double door fixed on flush to the wall including making the hole in the wall and fixing the DB including cement work and plastering complete including comprising the following all as specified and directed.
S&F, MCB SPN 40 to 63 Amps, 240 volts, 'C' curve complete all as specified and directed.
S&F, MCCB with thermal magnetic release 415 volts, 4 pole, 100 Amps capacity and breaking capacity 16 KA all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Supply, install, testing & commisioning of five star rated hi wall split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with latest invertor technology with hot & cold having ECO friendly refrigerent gas, copper condenser coil of capacity of 2 TR. Air conditioner including copper piping for suction and discharge line of suitable size duly insulated including control cable as supplied by manufacturer including initial filling of refrigerant gas and other components as required and necessary fixing arrangement at suitable height complete all as specified and directed. Make: VOLTAS / BLUE STAR / HITACHI / DAIKIN / CARRIER.
S&F, voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts without put voltage stablized at 230 volts with accuracy of + 2.5% and of capacity 5 KVA all as specified and directed. Make: AE / VINTEE / APLAB / V-Gaurd / VOLINA / IT & E / EMERSON / ANDREW YULE.
Supply & laying of extra copper pipe 5 / 8" (inch) with nitrile rubber tubular insulation and copper cable using necessary supports and fastners all as spcified and directed.
M&L for MS stand duly painted suitable for fixing 2 TR AC outdoor unit and fixed complete all as spcified and directed.
Making opening / drilling of size 65 mm dia, using heavy duty stone driller / cutter machinery in the stone machinery wall for installing spilit type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc and making good the disturbed surface all as directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole 20 Amps, 240V, MCB with 'C' curve all as specified and directed.
Supply & lay, HDPE pipe 25mm dia as in for drain pipe in any length with accessories and fxing arrangement on wall / roof etc as per site requirement complete all as specified and directed.
Sub main wiring complete with 2 runs of 6 Sqmm PVC insulated and unsheathed cable with multistranded, FRLS grade copper conductor confirming to IS-694, 1100 volts grade with colour code and drawn through and including 25mm dia PVC non metallic rigid conduits medium grade and conduit accessories concealed in walls / floors but except beams / roofs etc and connecting terminal ends including 1 x 6.0 Sqmm PVC insulated unsheathed copper conductor cable green colour as continuous earth continuity conductor and connecting to earth complete all as specified and directed. Note: Two runs of 6.0 Sqmm copper cable, one run of earth wire of 6.0 Sqmm copper cable and 25mm dia PVC conduit shall be measured and paid as one RM.
Supply, install, testing & commissioning of silent type Diesel Engine Driven Generating set, fully wired alternator AC to give an output of 160 KVA continuously rating at a power factor of 0.8 lagging, 3 phase, 4 wire, 415 volts, 50Hz, 1500 RPM directly coupled with diesel engine water cooled, mounted on common base frame complete with acoustic enclosure (canopy) with latest CPCB norms, fuel line & accessories, control panel showing standard parameters of Engine and Alternator, AMF Panel with control cable, exhaust pipe, fuel tank, PCC foundation work as per manufacturers instructions, anti vibration pads and other standard accessories and comprising of the folllowing, complete all as specified and directed.
(A) Alternator: Standard design alternator capacity of 160 KVA net out put at site after considering derating as per site condition at 0.8 power factor (lagging) 3 Phase, 4 wire, 415 Volts, 50 HZ, 1500 RPM, self excited, self regulated with brushless excitation automatic voltage regulator, screen protected drip proof IP23 enclosure, insulation class 'H' directly coupled with diesel engine through flexible coupling. The Alternator shall be suitable for tropical climate and shall conform to BS-2613 / 5000 / IS-4722 as amended upto date. (B) Diesel Engine: Water cooled Diesel Engine suitable for 160 KVA, 4 stroke, 6 cylinder, turbo charged to deliver not less than 144.5 BHP at 1500 RPM under NTP conditions and conforming standards BS-5514 and ISO-3046, the engine is prime rated with 10% over load capacity for one hour in any 12 continuous hours of operation. The engine shall be provided with electrical starting arrangments and shall give the electrical out put of 160 KVA at 0.8 power factor, 415 volts including standard accessories and comprising of following: -
(i) Radiator with blower fan including guard. (ii) Pipe coupling for engine cooling system piping. (iii) Corrossion in-hibitor coolant. (iv) Paper element filters for fuel, Lube oil, Bypass. (v) Fly wheel housing and fly wheel. (vi) Engine bearing mechanism in flywheel housing. (vii) Flexible coupling. (viii) Dry type air cleaners and vaccum indicators. (ix) Residential silencers. (x) Stainless stell exhust flexible bellows. (xi) Motor driven priming pump. (xii) Electric starter. (xiii) Battery charging indicator.
(xiv) Exhaust piping made out of heavy duty mild steel pipe 'C' class of length 3.0 metres above the adjacent building height or as per recommendations of OEM to meet CPCB norms inclusive of all accessories and hardware, neccessary support steel structure stack including mineral wool insulation 2 inch thick suitable for 400 degree celcius temperature cladded with aluminium sheet for the entire length of exhaust pipe. (xv) Exhaust gas driven turbo charger. (xvi) Electronic governor. (xvii) First fill lube oil, coolent and diesel during commissioning and testing.
(xviii) Fuel injection pump. (xix) Engine control panel with all accessories and components dispaying the battery voltage and charging rate, water temparature lubricating oil pressure, engine speed, engine hours run, balance of fuel indicator. (xx) Safety control (trip and indication) for high water temparature, low lube oil pressure, low and high speed trip. (xxi) Common Base frame for engine and alternator made from structural steel channels / beams duly painted. (xxii) Battery set of 1 Nos maintainance free type 12 Volts, 130 AH capacity including copper conductor multistranded leads of suitable size and adequate length from starter to battery terminals.
Emission Standards for DG Sets (a) The emission limits of DG sets upto 128 KW / 160 KVA shall be incorporated as per the latest CPCB norms as published by the Gazette of India New Delhi dated 03 Nov 2022 vide S No. 716 Extraordinary Part-II - Section 3-Sub Section (i) and emission limits shall come into force from 01 Jul 2023. (b) The emission limits shall be tested through one of the five CPCB approved recognized labs as mentioned below: - (i) Automotive Research Association of India, Pune (Maharashtra). (ii) International Centre for Automotive Technology, Manesar (Haryana). (iii) Indian Oil Corporation, Research and Development Centre, Faridabad (Haryana). (iv) Indian Institute of Petroleum, Dehradun (Uttarakhand). (v) Vehicle Research Development Establishment, Ahmednagar (Maharashtra). (vi) DG set manufactured prior to 01 Jul 2023 shall not be allowed / acceptable.
(c) The Cost for incorporation of Emission Standards and testing is included in rate quoted by the contractor. (C) Acoustic Enclosure (Canopy) suitable for 160 KVA DG set made out of 1.6mm thick CRCA sheet duly powder coated painting all as incompliance with latest CPCB norms suitable to reduce noise level to 75 DB measured at 1.0 mtr distance for audible frequencies as per manufacturers specifications and comprissing of following: - (i) Rugged in construction maintainance free and modular design high quality accoustic insulation materials to be used as per IS 8183 for maximum sound absorption, accoustic layers shall be supported with perforated sheets a see through transparent window glass infront of engine panel to provide for monitoring the operation.
(ii) Emergency stop button at exterior body. (iii) Deliverables 75 DB at 1 mtr distance at 75% load under free field conditions. (iv) 02 Nos of 10 watt LED lamps for inside illumination. (D) AMF Panel: Auto Main Failure (AMF) panel board suitable for 160 KVA DG set, Outdoor type CPRI approved factory fabricated made out 3.15mm thick CRCA sheet, free standing, floor mounted, cubicle type, dust and vermin proof, ventilated, weather proof duly power coated painting with siemens grey paint, IP 54 class protection, totally enclosed conforming to IS 8623, double door with locking arrangement provided with removable hinged front and rear doors for eassy accessibility, internally prewired, copper bus bar of suitable rating including electrical and electronic components / accessories and comprising of following: -
(E) In built integral fuel tank 260 ltrs shall be provided with drain plug, air vent inlet and outlet connection, level indicator and provision for cleaning. (F) Civil Work: All civil works including RCC / PCC platform and related to foundations for commissioning of Generator set shall be as per recommendations of the manufacturer. The foundation drawing for DG Set shall be got approved by Engineer-in-Charge before laying of foundation including material required. Note: (a) The contractor shall arrange for artificial load including diesel, coolent and lube oil etc, for 12 hours testing at site are deemed to be included in rate quoted by the contractor.
(b) Contrctor shall submit the detailed specification, model No, Make, technical literature and foundation drawing of DG set for approval of GE. (c) Contractor shall submit AMF panel drawing with dimensions and arrangement of switch gear, metering devices and make / model of switch gear for approval of GE.
S&F, double compression copper stainless gland for fixing armoured cable in size 3.5 core, 150 Sqmm complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in hard / dense soil all as directed by Engineer-in-Charge.
Returing filling in including spreding leveling watering and well ramming in layer not exceding 25 cm as in soil all as specified and dirceted.
Removing excavated material to a distance n exc 50 m and deposting where directed at a level n exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cable providing with a layer 8cm thick before laying the cable and 15 cm thick after laying the cable complete all as specified and directed. Note: Punned thickness only will be measured for the purpose of payment.
M&L for un-reinforced pre cast concrete covers class LV type 250mm x 150mm x 40mm size factory made for cable protection complete all as specified and directed.
Supply & laying, LT cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 Sqmm 3.5 Core including taking up existing old unserviceable LT UG cable complete all as specified and directed.
Supply & laying, Synthetic Insulating Mat of 2.00Mtr x 1.00Mtr x 2.5mm thick complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metres below normal ground level with top edge of earth plate not less than 1.5 metres below ground level connected to galvanized iron strip 32 x 6 mm as earting lead upto 7.5 metres or upto test point / connecting pointby means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and earth strip protected by galvanized pipe light grade 40 mm bore light grade including necessary earth work and excavation in any type of strata, GI medium grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS hook 6mm dia MS bars etc complete all as specified and directed and testing on completion. Note: (i) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (ii) GI Strip above 7.5m will be measured and paid seperately. (iii) Earth resistance not exceeding 1.0 ohm.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 32 x 6 mm complete all as specified and directed.
Taking down the old unserviceable existing LT UG cable of size from 3.5 / 4 core to 50 Sqmm in trenches / pipes / pole for attending the repair, refixing / relaing back in trenches fixed on poles with complete connections all as specified and directed by Engineer-in-Charge.
S&F, double compression copper stain less gland for fixing armoured cable in size 3.5 core, 300 Sqmm complete all as specified and directed.
Supply & laying, LT cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core including taking up existing old unserviceable LT UG cable complete all as specified and directed.
S&F, Moulded Case Circuit Breakers for Distribution Network with thermal magnetic release type 4 pole, 250 Amps capacity 36 KA rupturing capacity in existing panel board including modification on existing panel if required, necessary connectioning with copper strips / suitable size of copper conductor wire from bus bar, provison of suitable size of copper lugs as per the out going cable complete all as directed.
Supply & lay, copper pipe 3/8" (inch) with insulation including control cable and connecting as per site requirement complete all as specified and directed.
Supply, install, testing & commissioning of CPRI approved outdoor type LT panel board suitable for 415 volts, 3 Phase, 4 wire, 50 Hz power distributon panel of suitable size, pre wired with adequate size of single core PVC insulated FRLS stranded copper conductor cable, control fuses, earthing terminals, lifting hooks, danger notice plate, free standing, front and back openable construction, floor mounting, dust and vermin proof of IP-54 protection as per IS-8623, provision for ventilation, compartmentalised design, hinged type double door with mechanical locking arrangement for each feeder, factory fabricated out of 3.15mm thick CRCA sheet, 7 tank process powder coated painting fixed on and including necessary earth work civil work with PCC 1:3:6 type C2 foundation and comprising of the following switch gear and accessories complete all as specified and directed: -
(g) LED Indicator lamp Red, Yellow, Blue - 01 Set (h) Complete internal wiring with suitable copper conductor wires - 1 Lot. (j) Provision of extra space for two more out going feeders suitable for 125 Amps MCCB. Note: (i) All termination of existing cable should be provided with aluminium lugs / thimbles and suitable size of glands & rate for the same is deemed to be included in the item. (ii) Contractor shall submit general arrangement drawing of LT panel with dimensions and arrangement of switchgear / metering and make and model of switchgear for approval of GE.
RASHMI BUILDERS
RAHUL ENTERPRISES
B5BUILDING SOLUTIONS
Lucky Enterprises
Sai Ram Builders
Moulya Builders
D NAGI REDDY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .