Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.8 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC BEING LOWEST AFTER CONSIDERING SCH OF CREDIT AND DISCOUNT AS APPLICABLE. | |
| 2 | L2₹89.5 L+₹12.9 L (16.8%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹92.7 L+₹16.1 L (21.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹1.0 Cr+₹26.5 L (34.6%)Rejected-Finance DIWANBADA MANEGAON POST OFFICE KHAMARIA JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | Rejected-Technical AVAS VIKAS NANDANPURA JHANSI UP 284003 | JHANSI | UTTAR PRADESH | 284003 | - | Rejected-Technical BEING NOT ENLISTED IN CATEGORY B (ii) AS PER NIT. |
Tender Value
₹77 L
EMD Value
₹1.4 L
Closing Date
21 Nov 2022, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT
Special repair / Replacement of BER transformer and other connected works in various locations and Provision of three phase electric supply and water connection including allied works for newly released MRI Complex/Centre at MH Jabalpur under GE(W
2022_MES_551465_2
81914/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JABALPUR
AS PER NIT
8 documents required · 8 mandatory
₹1,000
Yes
GE WEST JABALPUR
₹1.4 L
Yes
19 Dec 2022
25 Oct 2022
23 Nov 2022
25 Oct 2022
21 Nov 2022
8 Nov 2022
25 Oct 2022 - 7 Nov 2022
Amount
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 240 sqmm, 3.5 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion including taking out existing old unserviceable cable complete all as directed. Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately under respective items of BOQ.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 70sqmm, 3.5 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion including taking out existing old unserviceable cable complete all as directed. Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately under respective items of BOQ.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 11000 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 95 sqmm, 3 core conforming to IS 7098 / (PART-II) 1985 with the latest amendments and testing on completion including taking out existing old unserviceable cable complete all as directed. Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately under respective items of BOQ.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95 sqmm and testing on completion complete all as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95 sqmm and testing on completion complete all as directed.
Dismentling of air break gang operated switch vertical/ horizontal mounted incluidng insulators and operating mechanism for repair/ replacement of broken/ worn out components and insulators etc. and removing from site complete all as specified and as directed.
Earthing complete in replacement with galvanised steel earth pipe, medium grade, 3000mm long with outer dia 65mm and inner dia 50mm, laid in ground by drilling in the ground with top edge not less than 1.25 metre below ground level and filling the back fill compound complete with all as required and directed, as per Electrical Plate No. 2, with 32x6 mm GI strip as earthing lead up to testing point and making the earth pit of PCC as per sample as required at site and testing after completion complete all as specified and directed. (Note:- GI strip from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe medium grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth wire alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
Dismantling of unserviceable stay assembly carefully including stay wire necessary excavation and earth work in any type of soil, demolition of PCC of any type and removing from site complete all as specified and as directed.
Dismantling of insulators any size/ type from poles including removal from site complete all as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and exceeding 1.5m but n exc 3.0 metre in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and exc. 1.5m but n exc 3.0 metre in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed ( Note : Punned thickness will be measured for payment).
Supply and laying un-reinforced precast concrete cable covers, Class HV, Type1, flat, size 300mm x 180mm x 40mm complete all as specified and as directed.
Supply and laying modular bricks covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed.
Supply and fixing/ laying of 50mm bore dia GI pipe light grade in trenches/ under roads/ along pole/ wall including all fittings, ISI marked as required for cable protection etc complete all as specified and directed.
Supply and fixing/ laying of 80mm bore dia GI pipe light grade in trenches/ under roads/ along pole/ wall including all fittings, ISI marked as required for cable protection etc complete all as specified and directed.
Dismantling of old unserviceable GI earth wire from HT over head lines including removal from site complete all as directed.
Dismantling of existing old cross arms, bracings, supports etc of any section, FI clamps, nuts, bolts, insulators etc. from OH line and checking for re-use & removal of unserviceable cross arms, bracing, supports etc from site complete all as specified and directed.
Drilling (Horizontally) to existing road (maximum 10M wide) suitable for passing GI tubing of dia upto 80mm/ 100mm as required at site complete all as specified and directed. Note:- All necessary T&P required at site for drilling shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug , bolts, nuts & screws complete all as specified, type 410 SP - 55 of 11 mtr long including painting of pole with one coat red oxide primer & two coat of aluminum paint & embedded portion of pole shall be painted with two coat of black paint complete all as specified and as directed.
M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and dircted.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required with 32x6mm galvanised iron strip complete all as specified and directed.
M&L for new lightning arrestor Metal Oxide type complete with all fittings, transmision/ distribution class , current rating 12 kA suitable for 11 KV system, discharge capacity 65 kilo amps and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed. Make:- SCHNENIDER or BHEL or GE POWER or W/S INSULATORS or SOUTHERN INSULATORS or OBLUM as approved by GE.
M&L for new lightning arrestor Metal Oxide type complete with all fittings, transmision/ distribution class , current rating 65 kA suitable for 11 KV system, discharge capacity 65 kilo amps and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed. Make:- SCHNENIDER or BHEL or GE POWER or W/S INSULATORS or SOUTHERN INSULATORS or OBLUM as approved by GE.
Supply and fixing of new switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 32mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 200 Amp 11000 Volts including dropout fuse set 15 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed. Make:- JAIPURIA or PACTIL or BHEL or MEI as approved by GE.
Supply and fixing of new switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 32mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 400 Amp 11000 Volts including dropout fuse set 15 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed. Make:- JAIPURIA or PACTIL or BHEL or MEI as approved by GE.
Dismantling of old unserviceable ACSR conductors from HT over head lines including removal from site complete all as directed.
Dismantling of concrete poles/ struts, any size including stacking & removal from site complete all as directed.
Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main Aluminium bus bars of 800 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including the followings : (a) CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. (b) CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables, Make of LT Panel : Mc Layer Pvt Ltd, Tricolite, Asian Switchgear (c) INCOMING :- ACB 800 Amps, 4 pole, 415 volts, 50 kA, 50 Hz with microprocessor release IPR 1+ Make Legrand , ABB, Seimens, Havells - 01 No OUTGOING : (a) 4 pole MCCB having breaking capacity 36 KA of rating 320 Amps with adjustable & fixed Magnetic release, Ics = 100%Icu, Make Legrand, ABB, Seimens, Havells- 02 Nos (b) 4 pole MCCB having breaking capacity 36 KA of rating 250 Amps with adjustable & fixed Magnetic release, Ics = 100%Icu, Make Legrand-420218, ABB, Seimens mps with adjustable & fixed Magnetic release, Ics = 100%Icu, Make Legrand, ABB, Seimens, Havells - 02 Nos
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 No (Make : Legrand, L&T, Hager, Havells) (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 No (Make : L&T, Hager, Havells) (f) Current transformer (CT) of rating 800/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1 set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (Make : CG/L&T/Siemens) (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (j) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos. (k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) Danger Notice Plate -02 Nos (o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 2.5 Sqm front area) ' Make of Panel - Asian Switchgear/ Tricolite/Universal Switchgear/ McLayer Pvt Ltd Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurement of LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and cost of foundation is deemed to be included in the unit rate quoted against this item.
(xi) MCB Triple pole 16 Amps, 10 kA, 'C' series - 02 Nos (xii) MCB Triple pole 10 Amps, 10 kA, 'C' series - 03 Nos (xiii) Capacitor duty contactor 3 pole 50 KVAr - 03 Nos (xiv) Capacitor duty contactor 3 pole 25 KVAr - 03 Nos (xv) Capacitor duty contactor 3 pole 10 KVAr - 02 Nos (xvi) Capacitor duty contactor 3 pole 05 KVAr - 02Nos (xvii) Capacitor duty contactor 3 pole 2.5 KVAr - 03Nos (xviii) 22.5mm dia Push Button ON/OFF-10 set (xix) 22.5 mm dia LED Red - 10Nos (xx) 22.5mm dia LED Green-10 Nos (xxi) Armoured 2 core copper cable 1.5sqmm shall be provided for sensing CT (xxii) Sensing CT as per site load condition shall be provided alongwith APFC Panel (xxiii ) All power connection shall be done with 1100 volts FRLS copper flexible wire with copper termination of proper size and proper type (Make : MCCBs/MCB/LED/PB/Capacitor/Contactor/APFC : L&T/Siemens/Schneider) Make (APFC Panel) Tricolite/ McLayers/Universal Switchgear) (Notes (i) GA drawing for APFC panel shall be got approved from the Accepting Officer before manufacturing of APFC panels (ii) Pre dispatch inspection shall be arranged for routine test at manufacturer's workshop by the contractor (iii) Test report for powder coating shall be provided with panels (iv) The manufacturer shall have inhouse 8 tanks Powder coating Process Plant to avoid defective process (v) PCC plateform of suitable size shall be provided after demolition of existing PCC plateform, The cost of all above shall be demmed to be included in unit quoted rates.
Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 630 KVA (Level-1), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5%, continuous rating of capacity 630KVA including bushing on HT end & cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.0M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class 'B' bricks, brick masonary shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transfarmer shall also includes the cost of following accessories/ fittings :- (a) One cable box on primary (HV) side having cable glands suitable for OH conductor (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No. cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge.
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos (Make : Legrand, L&T, Hager, Havells) (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos ( Make : L&T, Hager, Havells ) (f) Current transformer (CT) of rating 800/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (Make : CG/L&T/Siemens) (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (j) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos. (k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) Danger Notice Plate -02 Nos (o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 2.5 Sqm front area) ' Make of Panel - Asian Switchgear/ Tricolite/Universal Switchgear/ Mc Layer Pvt Ltd Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.
Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 315 KVA (Level-1), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5%, continuous rating of capacity 315KVA including bushing on HT end & cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.0M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class 'B' bricks, brick masonary shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transfarmer shall also includes the cost of following accessories/ fittings :- (a) One cable box on primary (HV) side having cable glands suitable for OH conductor (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No. cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge.
(d) Dehydrating breather with first fill of dehydrating agent. (e) Themometer pocket on tank cover. (f) One No. 100mm dia dial type thermometer vapour pressure type having range 0-1200 C with temp reading pointer, max temprature indicator and resetting device. (g) Rating plate with terminal markings. (h) Two earthing terminals on tank/ tank cover to facilitate fixing of 32x6mm GI earth strip. (j) Oil level gauge. (k) Oil drain and filter valves. (l) Oil filter hole with cap/plug with connections complete. (m) Lifting lugs. (n) Air relief valve plug. (o) Plain solid cast steel detachable rollers - 04 Nos. (p) First fill of fresh transformer oil conforming to revevant IS and tested upto 50 KV dielectric strength upto top of core. (q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral. (r) Provision of 2 Nos danger boards 250x200mm size made out of 1.6 mm thich MS plate, vitreous enameled white, with letters, figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings/ accessories so as to confirm the whole transformer to IS-1180 (Part-I) : 2014. (t) Base channel 100x50mm of suitable length duly fixed on platform/ plinth including making locking arrangement. (u) Inspection Cover Make : ABB or SCHNIEDER (AREVA) or Crompton Greaves or RAJASTHAN TRANSFORMERS or ITE Gurgoan or GE Power as approved by GE.
Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 200 KVA (Level-1), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5%, continuous rating of capacity 200KVA including bushing on HT end & cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.0M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class 'B' bricks, brick masonary shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transfarmer shall also includes the cost of following accessories/ fittings :- (a) One cable box on primary (HV) side having cable glands suitable for OH conductor (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No. cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge.
(d) Dehydrating breather with first fill of dehydrating agent. (e) Themometer pocket on tank cover. (f) One No. 100mm dia dial type thermometer vapour pressure type having range 0-1200 C with temp reading pointer, max temprature indicator and resetting device. (g) Rating plate with terminal markings. (h) Two earthing terminals on tank/ tank cover to facilitate fixing of 32x6mm GI earth strip. (j) Oil level gauge. (k) Oil drain and filter valves. (l) Oil filter hole with cap/plug with connections complete. (m) Lifting lugs. (n) Air relief valve plug. (o) Plain solid cast steel detachable rollers - 04 Nos. (p) First fill of fresh transformer oil conforming to revevant IS and tested upto 50 KV dielectric strength upto top of core. (q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral. (r) Provision of 2 Nos danger boards 250x200mm size made out of 1.6 mm thich MS plate, vitreous enameled white, with letters, figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings/ accessories so as to confirm the whole transformer to IS-1180 (Part-I) : 2014. (t) Base channel 100x50mm of suitable length duly fixed on platform/ plinth including making locking arrangement. (u) Inspection Cover Make : ABB or SCHNIEDER (AREVA) or Crompton Greaves or RAJASTHAN TRANSFORMERS or ITE Gurgoan or GE Power as approved by GE.
Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 160 KVA (Level-1), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5%, continuous rating of capacity 160KVA including bushing on HT end & cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.0M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class 'B' bricks, brick masonary shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transfarmer shall also includes the cost of following accessories/ fittings :- (a) One cable box on primary (HV) side having cable glands suitable for OH conductor (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No. cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge.
(d) Dehydrating breather with first fill of dehydrating agent. (e) Themometer pocket on tank cover. (f) One No. 100mm dia dial type thermometer vapour pressure type having range 0-1200 C with temp reading pointer, max temprature indicator and resetting device. (g) Rating plate with terminal markings. (h) Two earthing terminals on tank/ tank cover to facilitate fixing of 32x6mm GI earth strip. (j) Oil level gauge. (k) Oil drain and filter valves. (l) Oil filter hole with cap/plug with connections complete. (m) Lifting lugs. (n) Air relief valve plug. (o) Plain solid cast steel detachable rollers - 04 Nos. (p) First fill of fresh transformer oil conforming to revevant IS and tested upto 50 KV dielectric strength upto top of core. (q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral. (r) Provision of 2 Nos danger boards 250x200mm size made out of 1.6 mm thich MS plate, vitreous enameled white, with letters, figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings/ accessories so as to confirm the whole transformer to IS-1180 (Part-I) : 2014. (t) Base channel 100x50mm of suitable length duly fixed on platform/ plinth including making locking arrangement. (u) Inspection Cover Make : ABB or SCHNIEDER (AREVA) or Crompton Greaves or RAJASTHAN TRANSFORMERS or ITE Gurgoan or GE Power as approved by GE.
Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 100 KVA (Level-1), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5%, continuous rating of capacity 100KVA including bushing on HT end & cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.0M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class 'B' bricks, brick masonary shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transfarmer shall also includes the cost of following accessories/ fittings :- (a) One cable box on primary (HV) side having cable glands suitable for OH conductor (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No. cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge.
(d) Dehydrating breather with first fill of dehydrating agent. (e) Themometer pocket on tank cover. (f) One No. 100mm dia dial type thermometer vapour pressure type having range 0-1200 C with temp reading pointer, max temprature indicator and resetting device. (g) Rating plate with terminal markings. (h) Two earthing terminals on tank/ tank cover to facilitate fixing of 32x6mm GI earth strip. (j) Oil level gauge. (k) Oil drain and filter valves. (l) Oil filter hole with cap/plug with connections complete. (m) Lifting lugs. (n) Air relief valve plug. (o) Plain solid cast steel detachable rollers - 04 Nos. (p) First fill of fresh transformer oil conforming to revevant IS and tested upto 50 KV dielectric strength upto top of core. (q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral. (r) Provision of 2 Nos danger boards 250x200mm size made out of 1.6 mm thich MS plate, vitreous enameled white, with letters, figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings/ accessories so as to confirm the whole transformer to IS-1180 (Part-I) : 2014. (t) Base channel 100x50mm of suitable length duly fixed on platform/ plinth including making locking arrangement. (u) Inspection Cover Make : ABB or SCHNIEDER (AREVA) or Crompton Greaves or RAJASTHAN TRANSFORMERS or ITE Gurgoan or GE Power as approved by GE.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete and pilasters, buttresses columns, posts etc complete all as specified & directed.
M&L for Precast Reinforced Cement Concrete(RCC) 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and minimum reinforcement as per relevant IS code and set in CM 1:6 complete all as specified and directed. ( Note :Reinforcement shall be measured and paid for separately.)
M&L Mild Steel TMT bar 8 mm dia, cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with & including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as directed.
M&L for 40mm graded broken stone aggregate for spreading/ loose filling in the substation or other places where directed including stacking materials in regular heap/ stack for measurement complete all as specified and directed. Note:- Stack measurements after considering engineering practice for voids shall be recorded in MB for payment of this item.
Schedule of credit amount of Rs. 1,77,580.00 to be deducted during AOC
Sachdeva Enterprises
H V ELECTRICALS
C L BHATIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .