| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹11,940
Closing Date
17 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Shalimar
Internal electrification for FST Lab for GCMS and HPLC machines top Floor of B Wing along with protection for MCCB and Individual circuitry by SPD and MSUs etc at Shalimar SKUAST Kashmir
2021_SKUST_119230_1
E-NIT 25 of 2020
Open Tender
Electrical Works
Item Rate
20 days
Shalimar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
Asstt.comptroller Estates office
₹11,940
Yes
18 Mar 2021
4 Mar 2021
18 Mar 2021
4 Mar 2021
17 Mar 2021
4 Mar 2021
120 days
Amount
INTERNAL WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable Havells/Polycab/Finolex in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 5/6 amps switch 6AX insysta CAT No: WSNSW11 with modular plate of Hager or Legrand Arteor CAT NO 573401 2/4/6/8/10 way
Group C
Wiring for light/ power/heating plug with 2X4 sq. mm FRLS PVC Havells/Polycab/Finolex insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for heating AC power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Havells/Polycab/Finolex
Wiring for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 16 sq. mm + 1 X 6 sq. mm earth wire Havells/Polycab/Finolex
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the modular plate & switch box including connections but including modular plate etc. as required. 2 +3 way 16 amps switchand socket including switch 16AX insysta CAT No: WSNSW61 and 6 / 16A glossy white WSNSK53 with modular plate of Hager or Legrand Arteor CAT NO 573411 and 573779 2/4/6/8/10 way and face plate
3 pin 5/6 amp socket outlet Galaxy white socket WSNSK42 Hager or Legrand Arteor CAT NO 573467 make
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 120W glossy white fan regulator CAT No WSNFC22 or Legrand Arteor CAT NO 573469
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supply , Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm dia ceiling fan. 5 Star make CG/Havells /Usha
Supply , Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 250 mm dia exhaust fan. Make CG/Havells /Usha
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Double door Hager make VYH12DH 12+2 way, 8+6+36 modules or Legrand CAT NO 607838
Supplying and fixing of MCB 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
TPN 63Amp hager /Legrand C type
Double pole 40 Amp hager /Legrand C type
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 160 Amp, 50 KA,FPMCCB Make Hager /legrand
Earthing with G.I. electrode 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.Chemical Electrode earthing with earthing compound 8 feet deep GI to Copper bonded 3 mtr electrode as per IS 30343 and complete with soil treatment , masonary chambers test link heavy duty CI cover etc along with 25x3mm strip with gun metal tapping jointer etc . Complete with distributor and 8 SWG annealed wire laid from distributor to all sub DB's and main panel .Complete job
Supplying and laying 32 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply , laying of 1100 V core 3.5 C 50 AXYY XLPE 1100V XLPE armored cable in ground 3 ft deep with sand cushioning job 6 inches , cable markers , tiles etc in 5" B Type Heavy duty pipe in , walls ,ceiling trenches etc complete with clamp and saddle cable tags , markers , sand tiles /bricks etc
Data socket outlet
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
S/ I of geyser 50 Ltr Racold /havells/Venus
Supply /installation of Mirror light fitting Havelll’s /Philps/ LED Slim type 4 ft with tube etc
Supply /installation of LED recess fittings Philips/Syska/havells 15 watt with other accessories complete Make Havells/Philips /Ledure
S/I of Shunt trip Coil with MSU and wiring etc 63 A Four Pole Make Hager or Equivalent in Legrand
Type 2 Imax 40kA (with reserve indicator & remote signaling) 4 module SPN440R Hager Make Surge Protection Device
Panels board : Indoor Supply, installation, testing of cubicle type indoor panels as specified and complete with : MS sheet box type lid with frame and hinged lid a. Tinned aluminium bus bar b. Switchgear wiring c. 7 tank pre treatment powder coated finish (Siemens White) d. Earthing e. Rotary handle f. Current transformer Size of control panel 600x 600x 300 mm duly fabricated fitted with 300 Amp TPN busbar strips GI nuts and bolts, washers ,angle iron stand 50x50x6MM300MM etc with digital LED voltmeter 0-500 V , Ammeter 0-500 Amp AE make with rotor switches ,indications ,cable glanding ,terminations, duly recessed in the wall. Having necessary space for main MCCB spacing with termination and solid connections copper 25 x3 MM connector wire anealead. Powder coated complete job. 2 set RYB phase indicating lamps with fuse LED type, Panel Make Legrand /L&T /ABB /Hensel /Equivalent
Note:-The rates quoted are inclusive of all carriages (Mechanical/Manual) of materials from source to site work and all extra charges complete in all respects.
POWER GEN SOLUTIONS
NEW ERA ELECTRICAL ENGINEERS
RZ ELECTRICAL WORK
M/S NATIONAL ENTERPRISES
stage.html
html • 0.02 MB
finance_228880.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .