Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.4 L+₹97,065 (4.52%)Rejected-AOC 128 CANTT ROAD GARHA JALANDHAR PUNJAB 144001 | JALANDHAR | JALANDHAR | PUNJAB | 144001 | L2 | Rejected-AOC Being L2 | |
| 3 | L3₹23.8 L+₹2.3 L (10.9%)Rejected-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-AOC Being L3 | |
| 4 | L4₹28.6 L+₹7.1 L (33.3%)Rejected-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L4 | Rejected-AOC Being L4 |
Tender Value
Refer Docs
EMD Value
₹51,000
Closing Date
26 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF LEH
CWE (AF) LEH PIN 194101
PROVN OF EXTERNAL SERVICES TO PRE-FAB SHELTERS AT VARIOUS POSTS AT AF STN LEH
2020_MES_373191_1
81123/E8
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
Leh
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Leh
₹51,000
Yes
23 Oct 2020
29 Aug 2020
28 Sept 2020
29 Aug 2020
26 Sept 2020
12 Sept 2020
29 Aug 2020 - 10 Sept 2020
60 days
Amount
PART-I B/R WORKS Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth and not exceeding 10Sqm on plan and getting out in hard/dense soil, trimming sides, leveling bottom, watering and well ramming bottom, complete all as specified and directed.
All as per Ser item No. 1 above but depth exceeding 1.5m but not exceeding 3.00m.
All as per Ser item No. 1 above but depth exceeding 3m but not exceeding 4.5m.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Removal of surplus (excavated) soil to a distance exceeding 50m but not exceeding 100m, and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Material and labour, Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Material and labour, Plain Cement Concrete (1:3:6) type C-1, using 20mm graded crushed stone aggregate as in copings, bed blocks for fixing holdfasts, bed plates, PCC benching / gola to juction of wall and roof / chhajja etc., including use and waste necessary form work, complete all as specified and directed.
Material and labour, 100mm bore cast iron branch piece, single, equal or unequal, ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and directed.
Material and labour, cast iron bend or taper 10mm bore, with cement joints, complete all as specified and directed. (Large bore measured)
Supply and fix, Cast iron (sand cast) soil, waste and vent pipes, 100mm dia bore, in any length with or without ears, with cement joints, laid in trenches or fix to wall with MS holder bats/clamps including nut and bolts as required, complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid separately.
Material and Labour, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate), bed to RCC pipe of 150mm dia, including packing under & haunching against the sides of pipe after they are laid and tested, in trenches, complete all as specified and directed.
Material and laobur, RCC pipes 150mm dia, class NP2, laid on concrete bed and jointed in cement sand mortar (1:1) and tested, complete all as specified and directed. Note : Concrete bed, haunching etc, shall be measured and paid separately.
Material and labour, PCC (1:3:6) type C-2, using 40mm graded crushed/ broken stone aggregate, as in foundation, filling & mass concrete, complete all as specified and directed.
Material and labour, pre-cast cement concrete block masonry with soild blocks type C1, 1:3:6 (20mm graded stone aggregate), exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.
All as per srl item No 15.00 here-in-before but laid dry
Material and labour, rendering 15mm thick plaster on fair faces of pre cast concrete block masnory surfaces in CM (1:4), in two layers i.e. 10mm in CM (1:6) and 5mm in CM 1:4) mixed with approved WPC as per manufecturer's instructions in 5mm layer only and finished fair & even without using extra cement, complete all as specified and directed. Note: WPC shall be measured and paid separately.
Supply only integral water proofing compound, complete all as specified and directed.
Material and labour, Precast RCC (1:1.5:3) type A-1 using 20mm graded crushewd stone aggregate, as in cover slabs / shelves, set in CM (1:4), including use and waste necessary form work, complete all as specified and direected. Note: Steel reinforcement bars shall be measured and paid separately.
Supply and fix, mild steel TMT bars 6 to 8mm dia & over, as in reinforcement, cut to length, bent to shape as required, including cranking, hooking ends and binding with MS wire (annealed) of thickness not less than 0.9mm dia, complete all as specified and directed.
Material and labour broken brick loose filling with aggregates of gauge 80mm to 150mm in soakage pits, soakage wells etc complete all as specified and directed.
Material & labour, formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), flat, rough finished surface, complete all as specified and directed.
Supply and fix, mild steel TMT bars 10mm dia & over, as in reinforcement, cut to length, bent to shape required, including cranking, hooking ends and binding with MS wire (annealed) of thickness not less than 0.9mm dia, complete all as specified and directed.
Material and labour, Reinforced Cement Concrete (1:1.5:3) type A-1, using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns, shelves, landing & the like, complete all as specified and directed. Note : Steel reinforcement bars and use and waste form work shall be measured and paid separately.
PART-II E/M WORK Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 95Sqmm 3.5core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: Excavation & earth work, sand cushioning and PCC Cable Cover for protection of cable shall be measured and paid separately.
All as per Serial item No. 27.00 here-in-before but 6 Sqmm 2 Core.
All as per Serial item No. 27.00 here-in-before but 25 Sqmm 4 Core.
Material & labour, earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted rate shall be inclusive of above all provisions.
Material & labour, Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth strip connected to earthing points of outdoor panel boards and protected by galvanized iron pipe light grade 40mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted rate shall be inclusive of above all provisions.
Supply and laying / fixing , GI pipe light grade 50mm dia bore for cable protection fixed to pole/wall or laid under floor/road/pavement, complete all as specified and directed. Note (s) : (i) MS clamps, nuts, bolts etc where required shall be measured and paid separately. (ii) Boring of holes under road or cutting of road & making good etc. shall be measured and paid separately.
All as per Serial item No. 32.00 here-in-before but 25 mm bore.
Material and labour cutting existing road/PCC hard standing/pavement for laying of under ground cable/GI tubing and making good to match with the existing surface with PCC 1:2:4 Type C-1 using 20mm graded stone aggregates including all excuation and earth wrok complete all as specified and directed. Note:- Only PCC shall be measured and paid.
Material and labour, mild steel Fe-290 (Grade E-165) quality as in small items such as clamps, hold fast, straps, bands, support for stays for rain water pipes, tie bar etc., including nut and bolts, if required, complete all as specified and directed.
Supply, fixing, connecting and commissioning of LT panel, factory made (CPRI approved), outdoor type (kiosk), floor mounted, compartment type, dust and vermin proof (IP-55 protection) suitable for 415volts grade, 3phase, 4wire 50Hz AC supply with 200Amp aluminium bus bar TPN, colour coded & sleeved, fabricated out of 3.15mm thick mild steel CRCA sheet mounted on 50mmx50mmx6mm angle iron frame and welded to 75cm long 50mmx50mmx6mm size angle iron legs (04 Nos), front & rear openable, with front hinged double door inclusive locking arrangement with provision of all incoming/outgoing cable entries alongwith suitable size double compression type cable glands and adopter boxes for incoming and outgoing cable & spray painting with two coats of first quality super enameled grey paint over and including a coat of red oxide primer, including anti-corrosive treatment (7 tank), legs grouted in floor in PCC (1:2:4) bed block of size 30cmx30cmx60cm, complete all as specified and directed, comprising the following :- (a) MCCB 100Amp, 4pole, 415 Volt, 50Hz, AC, with rupturing capacity 35KA with adjustable thermal and fixed magnatic release (I/C) - 01 No. (b) MCCB 25 to 40 Amp, 3pole, 415 Volt, 50Hz, AC, with rupturing capacity 25KA with adjustable thermal and fixed magnatic release (O/G) - 06 No.(inclusive of 01 No spare). (c) Pre-wired Digital meter with voltmeter, ammeter, slector switch, CTs and LED Indication Lights- 01 Set. (d) Bus bar chamber with electrolytic grade aluminum strip with heat shrink cable sleeves with colour code supported on epoxy resin based insulator 4 strips of suitable length for current rating 200 A.
Supply, fixing, connecting and commissioning of LT panel, factory made (CPRI approved), outdoor type (kiosk), floor mounted, compartment type, dust and vermin proof (IP-55 protection) suitable for 415volts grade, 3phase, 4wire 50Hz AC supply with 100 Amp aluminum bus bar TPN, colour coded & sleeved, fabricated out of 3.15mm thick mild steel CRCA sheet mounted on 50mmx50mmx6mm angle iron frame and welded to 75cm long 50mmx50mmx6mm size angle iron legs (04 Nos), front & rear openable, with front hinged double door inclusive locking arrangement with provision of all incoming/outgoing cable entries alongwith suitable size double compression type cable glands and adopter boxes for incoming and outgoing cable & spray painting with two coats of first quality super enameled grey paint over and including a coat of red oxide primer, including anti-corrosive treatment (7 tank), legs grouted in floor in PCC (1:2:4) bed block of size 30cmx30cmx45cm, complete all as specified and directed, comprising the following including taking down old unserviceable LT panel:- (a) MCCB 25 to 40 Amp, 4 pole, 415 Volt, 50Hz, AC, with rupturing capacity 25KA with adjustable thermal and fixed magnatic release (I/C) - 01 No. (b) MCB, SPN, 32 A, 10 KA (O/G) - 15 No (inclusive of 01 No. spare). (c) Pre-wired Digital meter with voltmeter, ammeter, slector switch, CTs and LED Indication Lights -01 set. (d) Bus bar chamber with electrolytic grade aluminum strip with heat shrink cable sleeves with colour code supported on epoxy resin based insulator 4 strips of suitable length for current rating 100 A.
M/S LIBE & CO
national engineering
VIJAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .