| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance NO 4 775 1 1ST CROSS VIVEKANANDAR STREET THASILDAR NAGAR MADURAI 625 020 | MADURAI | MADURAI | TAMIL NADU | 625020 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹11 L
EMD Value
₹11,000
Closing Date
27 Jan 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The panchayat President Kattikulam
The panchayat President Kattikulam
Construction of Single Class room Building at Kattikulam village and panchayat
2023_RDTN_283973_1
Class room- KattikulamPanchayat
Open Tender
Civil Works
Item Rate
180 days
manamadurai
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹11,000
27 Jan 2023
25 Jan 2023
27 Jan 2023
25 Jan 2023
27 Jan 2023
25 Jan 2023
Amount
EARTHWORK EXCAVATION for foundation in all soils and sub soils and to full depth as may be directed except in rock requiring blasting but inclusive of shoring, strutting and baling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of not more than 15cm thick, well rammed and consolidated and depositing the surplus earth within the compound in places shown by the departmental officers with initial lead and lift etc.,including levelling the sites complete complying with standard specifications and as directed.
Supplying and filling foundations and basement with filling M-Sand in layers not exceeding 15cm,thick,well wastered,rammed and consolitaded etc.complete complaying with standard specifications
cement concrete 1:4:8(one part of cement,four parts of sand and eight parts of hard broken stone)using 40mm gauge hand broken hard broken granite stone jelly complying with standard specifications in fountations and basement
Supplying and filling basement with filling Red gravel in layers not exceeding 15cm,thick,well wastered,rammed and consolitaded etc.complete complaying with standard specifications
Supplying and erecting CENTERING for sides and soffits including supports and strutting upto 3.29 m high for plane surfaces such as RCC SLABS, RECTANGULAR BEAMS, TEE or ELL BEAMS, LINTELS, BED BLOSKS. STAIRCASE WAIST and landing slabs, landing beams, canopy etc., in all floors with all cross bracings using mild steel sheets of size 90cm * 60cm and BG 10 stiffened with welded mild steel angles of size 25mm * 25mm * 3mm for boarding laid over countrywood joists of size 10cm * 6.50cm spaced at about 90cm centre to centre and supported by Casuarian props of 10cm to 13cm dia spaced at 75cm centre to centre etc., complete and as directed.
Supplying,fabrication and placing in position mild steel/Ribbed tor steel roads for all RCC works including cost of steel and bimdimg wire also in all floors,complete complying with standard specification
CEMENT CONCRETE 1:1.5:3 mix using 20mm machine crushed 20mm gauge hard broken granite stone jelly for all reinforced cement concrete works connected to this work excluding cenetering, shuttering and cost of reinforcement grills placed in position, but including laying, vibrating, curing and finishing, fixing fan clamps in the RCC floor and roof slab works wherever necessary and bearing surfaces of the wall at the sides and bottom of the slab, beams shall be finished smooth with cement mortar 1:3 (One cement and three sand ) and Kraft paper laid without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers.
Brick work in following cement mortar 1:5 using second class country bricks of size 23cmx11cmx7cm for the following including curing etc.complete complying with standard specifications.
For Basement
for Superstructur
SPECIAL CEILING PLASTERING and finishing all the RCC exposed surfaces such as RCC slabs, sunshades, canopies, staircase steps, landing slabs, etc. with cement mortar 1:3 (one cement and three sand) 10mm thick and including hacking the surfaces and providing necessary cem,ent mortar nosing beading as per size, specification wherever necessary using the same mix as directed by the departmental officers etc.,complete complying with standard specification.
PLASTERING with cement mortar 1:5 (one cement and five sand)12mm thick in all floors complying with standard specifications
WEATHERING COURSE CONCRETE using best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be added) over the RCC roof slabs in the proportion of brick jelly to lime being 32:12.5 by volume and laid in a single layer and consolidated to the required designed and finished thickness by beating the concrete with wooden beaters if approved pattern keeping the surface constantly wet by sprinkling lime jaggery water as per standard specification etc., complete as directed by the departmental officers.
Finishing the top of roof with one course of machine pressed tiles of size 230mmx230mmx20mm of approved quality in cement mortar1:3
providing granolithic floor finish of the following Thic with plain cement concrete 1:2:4(one cement,Two Sand and Four Aggregate)using 10 to 12mm gauge hard broken stone jelly including
Ceramic tiles flooring laying with new ceramic tiles of size 305x305x6mm laid in cm 1:3 including cost of white cement and labour charges etc complete
Painting new iron works such as steel doors,windows,ventilators,window bars,balustrades etc.,with two coats of best approved first qualitu and colur of synthetic enamel paint over the excluding priming coat etc
Supplying and fixing AC Rain water down fall pipes of following 110m dia meter etc.,,complete
Painting two Coats With best approved Synthetic enamel Paint two Coats including Cost and Conveyance etc Complete..,
Painting two coats with approved exterior Emulsion paint over one priming coat of cement plasterd wall surface and ceiling including cleaning preparing the surface and curing etc complete
Supplying & fixing with cuddapah slabs20-30mm thick for cup board thick and pointed with cement mortar 1:3 -10 Sqm
Wiring 2x1.5sq.mm(22/0.30)PVC insulated unshethead SC.cu.conductor of 1100 V grade in suitable PVC rigid pipe on wall ceiling with PVC accessories eith TV switch box with in flush with wall covered eith hylem sheet of 3mm thick with painting of suitable colour for open PVC ligid/fan point (SD No:22)
Supply and fixing single box type 4'-40w flourescent tube fitting wih copper choke and condensor with T.W tround block on wall or ceiling with flourecent tube with PVC unshethed copper leads from terminals to the fitting of tube light (SD 88)
Wiring 2x1.5sq.mm(22/0.30)PVC insulated unshethead SC.cu.conductor of 1100 V grade in suitable PVC rigid pipe on wall ceiling with PVC accessories eith TW switch box with in flush with wall covered eith hylem sheet of 3mm thick with painting of suitable colour for open PVC ligid/fan point (SD No:36) 5 pin plug point
Suplly and fixing of 1200mm sweep AC ceiling fan complete with stepped electronic regulator with 300mm down rod on the existing clamp SD110
Supply and fixing water tight bulk head fitting with guard(philips/bajaj/crompton/Klite)suitable for incandencent lamp and 60W bulb(SD no:83)
supply and run of 2 of 1.50sqmm polythene insulated PVC shethead heavy duty SC Copper conductor of 1100 V grade on 7/20 GI bearer wire for service connection mains (SD No:64)
Supply and fixing of TNEB Meter board suitable for 32A Single phase service connection with 32A Fuse unit(500V) 32A neutural link and eartg link(1'x1/8'' copper flat)) on TW plank of size 375mm x 300mm x19mm with supporting TW reepars of 1'' thick an either side with painting with suitable bolr and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit (SD No,125)
Supply and run of 2x1.5sqmm(22/0.3)PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 25mm dia GI pipe (Class "B')suitably bent at both ends with necessary angle iron upright and end supports for mains SD 69
Supply and fixing of 16 amps DP switch of 500V with metal Clad with Fuse and neatural SD 142
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
JEYARAJ MUNIASAMY
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .