| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC CHATAPADMAPUR BATTALA RAMNAGAR CONTAI DIST PURBA MEDINIPUR PIN 721 433 WEST BENGAL | CONTAI | PURBA MEDINIPUR | WEST BENGAL | 721433 | L1 | Accepted-AOC AOC is issued | |
| 2 | L2₹4.4 L+₹3,405 (0.77%)Rejected-Finance 2 SURI LANE GROUND FLOOR KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹4.5 L+₹7,110 (1.61%)Rejected-Finance DAKHIN SHIBGANJ P O PATHAR PRATIMA SOUTH 24 PGS | PATHAR PRATIMA | SOUTH 24 PARGANAS | WEST BENGAL | 743371 | L3 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹8,937
Closing Date
27 Sept 2023, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Office of the Executive Engineer Purba Medinipur
Office of the Executive Engineer Purba Medinipur Electrical Division P.W.D.
SITC of AC Machine and allied EI work for the office at CMOH office in Purba Medinipur1st Retender
2023_WBPWD_558239_2
WBPWD/EE/PMED/NIQ-10/2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
tamluk
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,937
Tamluk
26 Nov 2025
5 Sept 2023
29 Sept 2023
5 Sept 2023
27 Sept 2023
12 Sept 2023
11 Sept 2023
Supplying & Fixing best quality (1/2'' thick) bakelite board (3' x 2') fixing with suitable fastner on wall incl. S & F 03 nos. 415 V, 200 A kit-kat rewireable fuse (Porcelain fuse carrier & base) & 01 no. 415 V, 200 A Cu neutral link(Make: Havells) on porcelain chair fixed on the bakelite board. [NS]
Supplying and fixing 415V, 63A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make-L&T/ Schneider/ Siemens)
Supplying & fixing of 4 bars 415 V, 315 A sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (Wire make Finolex/ Polycab/ havells/RR Kable) a) 2X 56/0.3( 4 sqmm) + 1 X 36/0.3( 2.5 sqmm) as ECC ( For AC)
S & Laying of cable on wall/surface including S & F MS clams with earthing attachment in 2x10 SWG GI(Hot Dip) Wire,making holes etc as necessary mending good damages & painting (Make- Polycab/ Havells/ RR Kable/Gloster)
a) 4 core 16 sqmm 1.1Kv grade XLPE insulated Al/A cable. (From Busbar to PDB)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC & finishing the end of the following XLPE/PVC armoured cables by crimping method incl S & F solderless socket ( Dowels Make) with tapes, anticorrosive paste & jointing materials .
4 Core 16 sqmm XLPE/PVC armoured cable
Supplying and fixing 415 V, 25-32A per way, 4way TPN MCBDB with SS enclosure double-door with IP-42/43 protection with 63A Four Pole Isolators as incomer and 18 non SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 63A FP Isolator, 12 no. (16-32A) SPMCB. (Make- Legrand)
S&F 250V 21A OLP-3+ Automatic single phase motor starter with VOLTCHECK, AMPCHECK & TIMECHECK and 3-digit display conceal in wall incl. 6 module GI box. [ Make- Electron, OLP3+.], (for AC machine controll)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket(Make - Legrand Myrius/Anchor Roma urban/ MK Honeywell Wraparound), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire
Supply & Delivery of Hi-wall Split Air Conditioner having following specification. Cooling Capacity - 6.6 kW (minimum) ISEER-3.5 (minimum) IS compliance - IS 1391 Refrigerant - R410A/ R32 Compressor - Rotary/Scroll Evaporator & Condensor Coil : Copper Operating Outdoor Temparature = 50ºC and above Power Supply - 230V,50Hz ( +Tolerrance as per applicable standard) The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrial rubber insulation,protective wrapping tape - 3 mtr (ii) necessary copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr (iii) Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator Anchor/North West/Legrand/) & necy. Connections.-3 nos [Make: Mitsubishi Electric /O General / Daikin]
Installation,Commissioning and testing of 2.0/1.5 ton split type AC machine both indoor/outdoor including fixing of 40 x 40 x 5 mm MS angle iron frame and mending good the damages.(incl. laboue cess)
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. (i) Supply & Fixing of extra refrigerant pipe with insulation foam insulation (as requisite dia) with protective wrapping tape [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia].
Do----Do----Do (ii) 3/4 core 2.5 sq mm PVC insulated PVC sheathed unarmoured Copper Cable (Make Finolex/ Havells/Polycab/RR /Gloster)
Supply & Fixing of 18mm dia PVC drain pipe (make approved by EIC)
MAHESWAR ELECTRICAL INDUSTRIES
B. ENGINEERING CO.
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .