| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | ₹39.5 L Quoted ₹39.9 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹42.7 L+₹2.8 L (7.04%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | ₹42.7 L+₹2.8 L (7.04%) | L2 | Rejected-Finance NOT THE LOWEST BIDDER |
| 3 | L3₹43.2 L+₹3.3 L (8.24%)Rejected-Finance LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | ₹43.2 L+₹3.3 L (8.24%) | L3 | Rejected-Finance NOT THE LOWEST BIDDER |
| 4 | L4₹44.0 L+₹4.1 L (10.3%)Rejected-Finance | ₹44.0 L+₹4.1 L (10.3%) | L4 | Rejected-Finance NOT THE LOWEST BIDDER |
| 5 | L5₹44.2 L+₹4.3 L (10.8%)Rejected-Finance | ₹44.2 L+₹4.3 L (10.8%) | L5 | Rejected-Finance NOT THE LOWEST BIDDER |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
5 Jun 2025, 6:00 pmClosed
CWE DINJAN
COMMANDER WORKS ENGINEER DINJAN
SPL REPAIR REPLACEMENT OF OVERHEAD ACSR CONDUCTOR WITH UG CABLE AT ZONE III MD ACCN AREA AT DINJAN
2025_MES_708057_1
84445/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE DINJAN
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
GE DINJAN
₹77,000
Yes
18 Jul 2025
14 May 2025
12 Jun 2025
14 May 2025
5 Jun 2025
31 May 2025
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable all as specified and directed at site.
Excavation in trenches in hard/dense soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable all as specified and directed at site.
Returning, filling in including spreading, leveling, watering and well ramming excavated soft/loose soil in layers , all as specified and directed at site
Removing excavated material surplus (soil ) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L for sand cushioning to under ground cable using locally available fine clean dry river sand over,under ground UG cable laid in treches and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge.
Supplying and laying reinforced precast concrete cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed.
S&F in repair,given size bore tubing “light grade” in trenches/ on pole for protection of cables complete all as specified & directed by Engineer-in-charge : 50 mm bore
As per Item No 07 : 32 mm bore
As per Item No 07 : 80 mm bore
Supply ,laying & testing in trenches / pole cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade with cross-sectional area of 120 sq mm 3.5 core
As per Item No 10 but cross-sectional area : 95 sq mm 3.5 core
As per Item No 10 but cross-sectional area : 70 sq mm 3.5 core
As per Item No 10 but cross-sectional area : 50 sq mm 3.5 core
As per Item No 10 but cross-sectional area : 35 sqmm 3.5 core
As per Item No 10 but cross-sectional area : 25 sqmm 3.5 core
As per Item No 10 but cross-sectional area : 16 sq mm 4 core
As per Item No 10 but cross-sectional area : 10 sqmm 4 core
As per Item No 10 but cross-sectional area : 25 sqmm 2 core
As per Item No 10 but cross-sectional area : 16 sqmm 2 core
As per Item No 10 but cross-sectional area : 10 sq mm 2 core
Dismantling of old/rusted aluminium conductor steel reinforced of any size and removing the same from site of work all as specified and directed by Engineer-in-Charge.
Dismantling of old/rusted Cross arms,bracings, supports, clamps and back plates including nut bots etc any size and removing the same from site of work all as specified and directed by Engineer-in-Charge.
Material and Labour in repair, dismantling the all cable from panel, poles, MCB Main DBs taking out the cable loop stretching out the cable, carrying out end termination with new lugs, proper thimbling, fixing the joint kits connecting back to the new/existing panel board by means of nuts, bolts & washers of any size any type all as directed by engineer in charge. Note: (i The work includes necessary excavation to take out the loop,and laying the cable, putting proper cable protection bricks using the old retrived bricks and refill the area properly and spreading any surplus soil (ii) The cost of Al lugs, joint kit shall be measured and paid separately under relevant items of schedule
Supply & fix for cable straight through joint for 1100 volt, out door type terminal cold shrinkable type joint complete with all jointing material and accessories suitable for 3.5/4 core 70-150sqmm, complete all as specified and directed. By engineer-in-charge.
Supply & fix for cable straight through joint for 1100 volt, out door type terminal cold shrinkable type joint complete with all jointing material and accessories suitable for 2/3.5/4 core 25-50sqmm, complete all as specified and directed. By engineer-in-charge.
Supply & fix for cable straight through joint for 1100 volt, out door type terminal cold shrinkable type joint complete with all jointing material and accessories suitable for 2 core 10-25sqmm, complete all as specified and directed. By engineer-in-charge.
S&F new PVC cable Junction Box IP66 "halogen free and weather proof" for out door installation size not less than 200 x 150 x 100 mm suitable for street light incoming and outgoing cables up to 10 to 25 sqmm 4 core (with terminal) & inclusive of MCB SP 10 Amp, 60A 04 strip aluminium Bus Bar, including nuts,bolts,cable glands & MS clamps fixed to pole all as directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire unarmoured, electric control cables (Heavy duty) with stranded Aluminium conductor of size 1.5 sq mm ,2 core, 1100 Volts grade passed throuh PVC conduit medium grade of size Min 20mm complete all as specified and directed.
M&L Earthing complete with Galvanised steel earth plate 60cmx60cmx6mm thick electrode, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 m below ground level , connected to GI earth strip 25 X 4mm up to test point by means of bolts ,nuts , check nuts and washers of GI including excavation and earth work, PCC 1:3:6 type C-1 pit, 20mm dia GI pipe medium grade, watering pipe and 20 mm bore GI pipe, light grade for protection of earth strip, MS angle iron frame 40x40x3mm, 10mm thick RCC 1:2:4 type B-1 cover reinforced with 6mm dia MS bars @ 75mm C/C both ways and with MS handle made out of 12mm dia bars, PGI Funnel, wire mesh etc complete all as shown in electrical Plate No 03 of SSR Part-I and connected to earthing test point all as specified or indicated including testing on completion complete and including taking down old u/s.
Supply, install, testing and commissioning outdoor type LT panel of size 1.2m x 1.2m x 0.6m , with latest IP 65 factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable entry/exit point in both front and rear door painted with powder coated paint and Aluminium bus bar 500 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type (mix ratio 1:3:6) painted with white/red color all around the panel board complete with the following items:- (Main Panel) Note : Foundation to be included in the quoted price Incoming :- (a) MCCB, 4 Pole, 400A, 415 V, 36 kA. (I/C). Thermal Magnetic release (b) 3 Phase LED Voltmeter Cl-1 (c) Phase indicator lamps (RYB) -set of 3 (d) Aluminium bus bar 4 strip - 500 amps (length should not be less than 0.7 m) (e) Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc Outgoing :- (a) MCCB, 4 Pole, 250 A, 415 V 25 kA - 01 nos (b) MCCB, 4 Pole, 160 A, 415 V 25 kA - 02 nos (c) MCCB, 4 Pole, 100 A, 415 V 25 kA - 01 nos (d) MCB, TPN, 32 A, 240 V, 18 kA - 01 No. (e) MCB,TPN, 63A, 240 V, 18 kA - 01 Nos.
Supply, install, testing and commissioning outdoor type LT panel of size 1.2m x 1.2m x 0.6m , with latest IP factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and Aluminium bus bar 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (FP-II) Note : Foundation to be included in the quoted price Incoming :- (a) MCCB, 4 Pole, 250A, 415 V, 25 kA. (I/C). Thermal Magnetic release (b) 3 Phase LED Voltmeter Cl-1 (c) Phase indicator lamps (RYB) -set of 3 (d) Aluminium bus bar 4 strip - 500 amps (length should not be less than 0.7 m) (e) Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc Outgoing :- (a) MCCB, 4 Pole, 160 A, 415 V 25 kA - 01 nos(FP-III) O/G (b) MCB, TPN, 32 A, 240 V, 18 kA - 01 No. (c) MCB,TPN, 63A, 240 V, 18 kA - 06 Nos.
Supply, install, testing and commissioning outdoor type LT panel of size 1.2m x 1.2m x 0.6m , with latest IP 65 factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable entry/exit point in both ront and rear door painted with powder coated paint and Aluminium bus bar 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type (mix ratio 1:3:6) painted with white/ red color all around the panel board complete with the following items:- (FP-I & FP-IV) Note : Foundation to be included in the quoted price Incoming :- (a) MCCB, 4 Pole, 250A, 415 V, 25 kA. (I/C). Thermal Magnetic release (b) 3 Phase LED Voltmeter Cl-1 (c) Phase indicator lamps (RYB) -set of 3 (d) Aluminium bus bar 4 strip - 300 amps (length should not be less than 0.7 m) (e) Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc Outgoing :- (a) MCB, TPN, 32 A, 240 V, 18 kA - 02 No. (b) MCB,TPN, 63A, 240 V, 18 kA - 06 Nos.
Supply, install, testing and commissioning outdoor type LT panel of size 1.2m x 1.2m x 0.6m , with latest IP 65 factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable entry/exit point in both ront and rear door painted with powder coated paint and Aluminium bus bar 300 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type (mix ratio 1:3:6) painted with white/red color all around the panel board complete with the following items:- (FP-III & FP-V) Note : Foundation to be included in the quoted price Incoming :- (a) MCCB, 4 Pole, 160A, 415 V, 25 kA. (I/C). Thermal Magnetic release (b) 3 Phase LED Voltmeter Cl-1 (c) Phase indicator lamps (RYB) -set of 3 (d) Aluminium bus bar 4 strip - 300 amps (length should not be less than 0.7 m) (e) Internal connection by Aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etc Outgoing :- (a) MCB, TPN, 32 A, 240 V, 18 kA - 02 No. (b) MCB,TPN, 63A, 240 V, 18 kA - 06 Nos.
Materials and labour for PCC ( 1:4:8) type D-2 Using 40 mm graded stone aggregate as in foundation of stay assembly , poles struts etc. complete all as specified and as directed .
Dismantling insulators any type, any size
Dismantling of GI Earth wire 40mm or any size
M&L for horizantal boring/drilling hole mannual under the road in soft/loose soil without cutting/disturbing the existing road and inserting GI pipe 80/50/40/32mm bore for drawing the cables complete all as directed and specified. (Note: (i) Cost of acessories required for making hole/bore deemed to be included in the quoted rate. (ii) GI pipe has been measured and paid separately)
S&F RCC cable route indicator with embrossing mark as LT cable, of size 75 cm x 15cm x 7.5cm complete all as specified and directed.
Supply, install, testing and commissioning outdoor type LT panel of size .6m x 0.6m x 0.5m , with latest IP 65 factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement with magnetic door closing system, neoprene gasket and gland packing at cable entry/exit point in both front and rear door painted with powder coated paint and Aluminium bus bar 200 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform type (mix ratio 1:3:6) painted with white/red color all around the panel board complete with the following items:- (Bus Bar Panel). Note : Foundation to be included in the quoted price (length of bus bar should not be less than 0.35 m) (a) Aluminium bus bar 4 strip of 200 Amps having hole drilled on Bus Bar for fixing of cables.
STANDARD ELECTRIC WINDERS (BID ID -3313983)
M/S A K BROTHERS (BID ID -3313016)
M/s GANDHESWAR PHUKAN (BID ID -3313823)
FREEZCON (BID ID -3311875)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .